• Title/Summary/Keyword: Buckling resistance

Search Result 203, Processing Time 0.025 seconds

Shake table responses of an RC low-rise building model strengthened with buckling restrained braces at ground story

  • Lee, Han Seon;Lee, Kyung Bo;Hwang, Kyung Ran;Cho, Chang Seok
    • Earthquakes and Structures
    • /
    • v.5 no.6
    • /
    • pp.703-731
    • /
    • 2013
  • In order to verify the applicability of buckling restrained braces (BRB's) and fiber reinforced polymer (FRP) sheets to the seismic strengthening of a low-rise RC building having the irregularities of a soft/weak story and torsion at the ground story, a series of earthquake simulation tests were conducted on a 1:5 scale RC building model before, and after, the strengthening, and these test results are compared and analyzed, to check the effectiveness of the strengthening. Based on the investigations, the following conclusions are made: (1) The BRB's revealed significant slips at the joint with the existing RC beam, up-lifts of columns from RC foundations and displacements due to the flexibility of foundations, and final failure due to the buckling and fracture of base joint angles. The lateral stiffness appeared to be, thereby, as low as one seventh of the intended value, which led to a large yield displacement and, therefore, the BRB's could not dissipate seismic input energy as desired within the range of anticipated displacements. (2) Although the strengthened model did not behave as desired, great enhancement in earthquake resistance was achieved through an approximate 50% increase in the lateral resistance of the wall, due to the axial constraint by the peripheral BRB frames. Finally, (3) whereas in the original model, base torsion was resisted by both the inner core walls and the peripheral frames, the strengthened model resisted most of the base torsion with the peripheral frames, after yielding of the inner core walls, and represented dual values of torsion stiffness, depending on the yielding of core walls.

A Study on Lateral-Torsional Buckling Strength Equation of Compact T-Beam Subjected to Pure Bending (균일모멘트를 받는 조밀단면 T형보의 횡-비틀림 좌굴강도 기준식에 관한 연구)

  • Park, Jong-Sup;Kim, Yong-Hee;Yi, Gyu-Sei
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2038-2043
    • /
    • 2009
  • This study investigates elastic lateral-torsional buckling(LTB) of T-beams subjected to pure bending using finite element analysis(FEA). The results from the FEA are compared with those from the current American Institute of Steel Council(AISC) Load and Resistance Factor Design(LRFD) Specifications. The comparison indicates that AISC-LRFD provide unsafe values for T-beam subjected to pure bending. Therefore, a new design equation are presented using results from the FEA. The new equation could be easily used to calculate the elastic lateral-torsional buckling moment resistance of T-beam for beam design and to expand the new equation for developing LTB equations of T-beam subjected to general loading conditions such as a concentrated load, distributed load, or a seres of concentrated load.

A Study on the Evaluation of Member Buckling Performance of Space Frame Structures (스페이스 프레임 구조물의 부재좌굴성능 평가방안 연구)

  • Kang, Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.176-182
    • /
    • 2018
  • The purpose of this study was to investigate the safety and rationality of buckling strength and length coefficient by comparing with the design standards of domestic and foreign compression materials based on the buckling test results of circular steel pipe with ball joints. The types of round steel pipes selected for buckling performance evaluation were ø$48.6{\times}2.8t$, ø$60.5{\times}3.2t$ and ø$76.3{\times}3.2t$. For the design of domestic and foreign compression materials, Korea 's Load Resistance and Factor Design, Japan' s Limit State Design, and British Standard BS5950 standard were applied. In this study, we compared and analyzed the buckling performance between the experimental results of the previous research and the domestic and foreign design standards. The results were summarized as follows. As a result of applying the full length of the member to the buckling length in the compression materials design standards of each country, it was 64-89% of the buckling strength by the experiment. Therefore, it is deemed desirable to perform the member design according to the current design standard formula for safety. Experimental results show that the measured buckling strength was 1.02-1.43 times higher than the buckling strength of pure cylindrical steel tubes in the design standards of Korea, Japan and the United Kingdom compression materials. Consequently, it seemed that the buckling strength of individual member in the design of space frame structure should be considered buckling coefficient as the length of pure round steel pipe rather than the length of inter-node.

A Study on the Characteristics of SM570TMC Plates in Compression Members (SM570TMC 강재의 압축재 특성에 관한 연구)

  • Im, Sung Woo;Kim, Yo Suk;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.357-363
    • /
    • 2005
  • There is a great need for high-strength steel especially for the high-rise steel building structure. High-strength steels, however, may have mechanical properties that are significantly different from those of the conventional steels. The application of high-strength steels to building structures should be reviewed as to whether the inelastic behavior equivalent to that of conventional steels can be attained or not. In this study, SM570TMC steel was tested to evaluate buckling strength under axial compressive force. The comparison tests for local buckling strength evaluation of box-type and H-shaped welded columns were performed with variable width-thickness ratios. As for the experimental check, the maximum strength of stub column was determined by local buckling as far as the limit of width-to-thickness ratio was satisfied with current design codes. Also, the strength of the stub column did not decrease suddenly by local buckling before maximum strength even when the ratio is not satisfied. The buckling strength of SM570TMC steel was higher than both ASD (Allowable Stress Design) and LRFD (Load and Resistance Factor Design) specifications.

Analytical study of elastic lateral-torsional buckling of castellated steel beams under combined axial and bending loads

  • Saoula Abdelkader;Abdelrahmane B. Benyamina;Meftah Sid Ahmed
    • Steel and Composite Structures
    • /
    • v.52 no.3
    • /
    • pp.343-356
    • /
    • 2024
  • This paper presents an analytical solution for correctly predicting the Lateral-Torsional Buckling critical moment of simply supported castellated beams, the solution covers uniformly distributed loads combined with compressive loads. For this purpose, the castellated beam section with hexagonal-type perforation is treated as an arrangement of double "T" sections, composed of an upper T section and a lower T section. The castellated beam with regular openings is considered as a periodic repeating structure of unit cells. According to the kinematic model, the energy principle is applied in the context of geometric nonlinearity and the linear elastic behavior of materials. The differential equilibrium equations are established using Galerkin's method and the tangential stiffness matrix is calculated to determine the critical lateral torsional buckling loads. A Finite Element simulation using ABAQUS software is performed to verify the accuracy of the suggested analytical solution, each castellated beam is modelled with appropriate sizes meshes by thin shell elements S8R, the chosen element has 8 nodes and six degrees of freedom per node, including five integration points through the thickness, the Lanczos eigen-solver of ABAQUS was used to conduct elastic buckling analysis. It has been demonstrated that the proposed analytical solution results are in good agreement with those of the finite element method. A parametric study involving geometric and mechanical parameters is carried out, the intensity of the compressive load is also included. In comparison with the linear solution, it has been found that the linear stability underestimates the lateral buckling resistance. It has been confirmed that when high axial loads are applied, an impressive reduction in critical loads has been observed. It can be concluded that the obtained analytical solution is efficient and simple, and offers a rapid and direct method for estimating the lateral torsional buckling critical moment of simply supported castellated beams.

Sensitivity of the ballast resistance and track irregularity on the track stability (궤도 안정성에 대한 도상저항력과 궤도틀림의 민감도)

  • Lim, Nam Hyoung;Choi, Sang Hyun;Lee, Chin Ok;Sung, Ik Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.519-526
    • /
    • 2005
  • During summer, very high compressive force occurs on the continuous welded rail (CWR) track because of the increase of rail temperature (max. $60^{\circ}C$). This extreme temperature stress can cause the CWR track to buckle. Among many CWR parameters affecting the track buckling, the influence of the lateral and longitudinal ballast resistance was investigated on the stability of the CWR track in this study. Also, the sensitivity of the track irregularity such as the alignment defect and the gauge irregularity was investigated.

Equations for Calculating Lateral-Torsional Buckling Capacity of H-Beam with Continuous Lateral Top-Flange Bracing (상부플랜지 연속 횡지지에 따른 초간편 H형강의 횡-비틀림 좌굴강도식 비교에 관한 연구)

  • Park, Jong-Sup;Lee, Son-Ho;Yoon, Ki-Young;Park, Jeong-Ung;Kim, Snag-Seup
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.437-440
    • /
    • 2007
  • Design equations for calculating the lateral-torsional buckling moment resistances of I-section beams with continuous lateral top-flange bracing subjected to several loading conditions are investigated based on elastic finite-element analyses. The equations presented in this study are compared with current moment gradient modifiers presented by other researchers and specifications. The equation suggested in the SSRC Guides(1998) has a good agreement with the results of finite-element analyses. The moment gradient correction factors proposed in the SSRC Guides(1998) should be easily used to calculate the lateral-torsional buckling moment resistance of I-beams with continuous lateral top-flange bracing.

  • PDF

Numerical Study of the Deformation Characteristics for Circle Shaped and Square Shaped PET Bottles under Compressive Loads (원형PET용기와 사각PET용기의 압축하중시 변형거동에 관한 수치적 연구)

  • Cho, S.H.;Kwon, C.H.;Park, G.M.;Ko, Y.B.
    • Transactions of Materials Processing
    • /
    • v.23 no.1
    • /
    • pp.5-9
    • /
    • 2014
  • Although much research has been conducted to reduce the thickness of PET bottles in order to save manufacturing costs, the challenge remains of guaranteeing mechanical strength for top-loaded thin PET bottles. The current study investigates the large deformation characteristics of a circle shaped PET bottle and a square shaped PET bottle when compressively loaded using FEA. The arc length method is used in the nonlinear FEA to understand the buckling phenomenon. For PET bottles with the same capacity, the circle shaped bottle shows more resistance to buckling and compression loading than the square shaped bottle.

Experimental study on shear behavior of I-girder with concrete-filled tubular flange and corrugated web

  • Shao, Y.B.;Wang, Y.M.
    • Steel and Composite Structures
    • /
    • v.22 no.6
    • /
    • pp.1465-1486
    • /
    • 2016
  • Conventional plate I-girders are sensitive to local buckling of the web when they are subjected mainly to shear action because the slenderness of the web in out-of-plane direction is much bigger. The local buckling of the web can also cause the distorsion of the plate flange under compression as a thin-walled plate has very low torsional stiffness due to its open section. A new I-girder consisted of corrugated web, a concrete-filled rectangular tubular flange under compression and a plate flange under tension is presented to improve its resistance to local buckling of the web and distorsion of the flat plate flange under compression. Experimental tests on a conventional plate I-girder and a new presented I-girder are conducted to study the failure process and the failure mechanisms of the two specimens. Strain developments at some critical positions, load-lateral displacement curves, and load-deflection curves of the two specimens have all be measured and analyzed. Based on these results, the failure mechanisms of the two kinds of I-girders are discussed.

Analysis of Pure Torsional Constant of I-Girder with Corrugated Webs (파형 복부판을 가진 플레이트거더의 순수비틀림상수 분석)

  • Jeon, Jin-Su;Kim, Sung-Nam;Yoo, Chai-Hong;Kang, Young-Jong
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.287-290
    • /
    • 2008
  • Resistance to lateral torsional buckling of steel I-girder (open section) is a very important design requirement. But, most studies of steel I-girder with corrugated webs were invested in shear behavior. Untill now, most studies about Lateral torsional buckling of I-girder with corrugated webs have been based on Lindner.J's study (Lateral torsional buckling of beamswith trapezoidally corrugated webs,1990). the study includes that the pure torsional constant of I-girder with corrugated webs $J_{cor}$ doesn't different from that of I-girder with flat webs. This paper pesents pure torsional constant of I-girder with corrugated webs by using finite element anaysis.

  • PDF