• 제목/요약/키워드: Bubble velocity

검색결과 250건 처리시간 0.026초

입자영상유속계에 의한 기포붐의 Plume 거동특성에 관한 연구 (A Study on Plume Movement Characteristics of Bubble Boom by PIV)

  • 조대환;오병주;이영호
    • 해양환경안전학회지
    • /
    • 제6권1호
    • /
    • pp.69-76
    • /
    • 2000
  • Bubble boom may be a good alternative for the prevention of oil spill pollution due to its easy deployment and clean post-process tasks. The present work is focused on the experimental investigation of air bubble movement for the bubble boom by visualization and quantitative PIV measurements. Bubble plume was generated by adjusting the pressure of pressure vessel ranging 6.7 kpa to 14.7 kpa. The results showed at lower inlet velocity and higher supply air flow rate that bubble boom maintained its containing capability reasonably well up to the maximum containing limit.

  • PDF

COMPUTATION AND ANALYSIS OF MATHEMATICAL MODEL FOR MOVING FREE BOUNDARY FLOWS

  • Sohn, Sung-Ik
    • 대한수학회지
    • /
    • 제37권5호
    • /
    • pp.779-791
    • /
    • 2000
  • The nonlinear stage of the evolution of free boundary between a light fluid and a heavy fluid driven by an external force is studied by a potential flow model with a source singlarity. The potential flow model is applied to a bubble and spije evolution for constantly accelerated interface (Rayleigh-Taylor instability) and impulsively accelerated interface (Richtmyer-Meshkow instability). The numerical results of the model show that, in constantly accelerated intergace, bubble grows with constant velocity and the spike falls with gravitational acceleration at later times, while the velocity of the bubble in impulsively accelerated interface decay to zero asymp flow model for the bubble and spike for constantly accelerated interface and impulsively accelerated interface.

  • PDF

유동층에서 기포의 유동특성에 관한 연구 (A Study on the Flow Characteristics of Bubbles in a Fluidized Bed)

  • 김용섭
    • 한국해양공학회지
    • /
    • 제10권3호
    • /
    • pp.117-124
    • /
    • 1996
  • A fluidized bed combustion chamber is widely used to incinerate waste material. The most important factor designing the incinerator is the flow characteristics in a fluidized bed, because combustion efficiency is influenced by the flow characteristics. This paper has invesitigated the flow characteristics of bubbles in fluidized bed by means of meassuring a pressure fluctuation in the fluidized bed. A pressure probe system has used to measure the pressure. The data concerned with bubble rising velocity, bubble size, distribution of bubbles and frequency of bubble generation or decay are obtained to find the flow characteristics of bubbles in the fluidized bed. The result obtained from this experimental study can be used to design the fuel feeding system of fluidized bed combustion type incinerator. And it is possible to predict the mixing of waste material and fluidizing material.

  • PDF

Characteristics of Gas-liquid Mass Transfer and Interfacial Area in a Bubble Column

  • Lim, Dae Ho;Yoo, Dong Jun;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • 제53권3호
    • /
    • pp.315-320
    • /
    • 2015
  • Characteristics of gas-liquid mass transfer and interfacial area were investigated in a bubble column of diameter and height of 0.102 m and 2.5 m, respectively. Effects of gas and liquid velocities on the volumetric gas-liquid mass transfer coefficient ($k_La$), interfacial area (a) and liquid side true mass transfer coefficient ($k_L$) were examined. The interfacial area and volumetric gas-liquid mass transfer coefficient were determined directly by adopting the simultaneous physical desorption of $O_2$ and chemical absorption of $CO_2$ in the column. The values of $k_La$ and a increased with increasing gas velocity but decreased with increasing liquid velocity in the bubble column which was operated in the churn turbulent flow regime. The value of $k_L$ increased with increasing gas velocity but did not change considerably with increasing liquid velocity. The liquid side mass transfer was found to be related closely to the liquid circulation as well as the effective contacting frequency between the bubbles and liquid phases.

X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시 측정기술 개발 (X-ray Micro-Imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-Bubbles)

  • 김석;이상준
    • 대한기계학회논문집B
    • /
    • 제28권6호
    • /
    • pp.659-664
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of 20∼60$\mu\textrm{m}$ diameter moving upward in an opaque tube (${\Phi}$=2.7mm) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

X-ray 미세 영상기법을 이용한 미세기포의 크기 및 속도 동시측정 (Synchrotron X-ray Micro-imaging Technique for Simultaneous Measurement of Size and Velocity of Micro-bubbles)

  • 김석;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1744-1748
    • /
    • 2004
  • It is important to measure precisely the size and velocity of micro-bubbles used in various field. The synchrotron X-ray micro-imaging technique was employed to measure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Phase contrast images were obtained at interfaces of micro-bubbles between water and air due to their different refractive indices. The X-ray micro-imaging technique was found to measure an optical fiber with an accuracy of 0.2%. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}=2.7mm$) were tested to measure bubble size and up-rising velocity. For DI water, the measured velocity of micro-bubbles is nearly proportional to the square of bubble size, agreed well with the theoretical result. In addition, the synchrotron X-ray micro-imaging technique can measure accurately the size and velocity of several overlapped micro-bubbles.

  • PDF

회류수조에서의 ABS에 의한 활주선 후류 기포항적계측 (Bubble Wake Measurement by Acoustic Bubble Spectrometer Generated by Planing Hull at Circulating Water Channel)

  • 신명수;문일성;나영인;박종천
    • 한국군사과학기술학회지
    • /
    • 제14권1호
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents bubble wake measurement results generated by the planing hull. The bubble was generated by SNAME TMB model(No. 4876) with hard chine at the CWC(Circulating Water Channel). ABS(Acoustic Bubble Spectrometer) was used to measure bubble wake measurement. The manufactured model is one meter in length and uniform velocity to generate the bubble at CWC is 3m/s, relatively higher speed than conventional hull form. Measurements were performed successfully and measured results show well the general characteristics of bubble wake generated by planing hull. Furthermore, experimental equations are proposed for the practical use.

기-액 향류 흐름 기포탑 생물 반응기에서 기포 흐름 거동 특성 (Characteristics of Bubble Flow Behavior in a Gas-liquid Countercurrent Bubble Column Bioreactor)

  • 손성모;강석환;이찬기;정성현;강용;김상돈
    • Korean Chemical Engineering Research
    • /
    • 제43권2호
    • /
    • pp.272-277
    • /
    • 2005
  • 직경이 0.152 m이고 높이가 3.5 m인 기-액 향류 흐름 기포탑에서 기포의 물성과 흐름의 거동을 고찰하고 진단하였다. 기체와 액체의 유속 그리고 기포의 분산형태(even, wall-side, central or asymmetric distribution)가 반응기 내부에서 기포의 크기, 빈도수, 상승속도와 체류량 등 기포특성에 미치는 영향을 이중 전기 저항 탐침법을 이용하여 측정 검토하였다. 기포의 크기, 빈도수와 체류량은 기체나 액체 유속의 증가에 따라 증가하였다. 기포의 상승속도는 기체 유속의 증가에 따라 증가하였지만, 액체 유속의 증가에 따라서는 감소하였다. 기포 크기 분포의 균일성이나 체류량은 기포 분산판에서 기포의 분산형태가 균일분포에서 벽면, 중앙 그리고 비대칭 분산으로 변화함에 따라 감소하였다. 기포의 체류량과 분포에 대한 균일성을 고려하면, 기포의 중앙 분산 형태가 비대칭 분산 형태보다는 유리하며, 벽면 분산형태분산보다는 좋지 않았다.

Bubble size characteristics in the wake of ventilated hydrofoils with two aeration configurations

  • Karn, Ashish;Ellis, Christopher R;Milliren, Christopher;Hong, Jiarong;Scott, David;Arndt, Roger EA;Gulliver, John S
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권2호
    • /
    • pp.73-84
    • /
    • 2015
  • Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine requires a precise understanding of the dependence of the generated bubble size distribution upon the operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two blade designs differed in their location of air injection. Extensive sets of experiments were conducted by varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.

TLC 를 이용한 사각공동내의 열전도 영역에 기포의 형성으로 인한 열전달 현상 구명 (A Study of Heat Transfer Phenomena due to a Formed Gas Bubble under Heat-Conduction Domain in A Closed Square Cavity)

  • 엄용균;유재봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.85-89
    • /
    • 2003
  • In a closed square cavity filled with a liquid, a cooled the upper horizontal wall and a heated the lower horizontal wall, the flow isn't generated under the ground-based condition when Rayleigh number is lower than 1700. In such case the flow phenomena near an air bubble under a cooled horizontal wall were investigated. The temperature and the flow fields were studied by using the Thermo-sensitive Liquid-Crystal and the image processing. The qualitative analysis for the temperature and the flow fields were carried out by applying the image processing technique to the original data. Injecting bubble at the center point of upper cooled wall, the symmetry shape of two vortexes near an air bubble was observed. The bubble size increased, the size of velocity and the magnitude of velocity increased. In spite of elapsed time, a pair of two vortexes was the unique and steady-state flow in a square cavity and wasn't induce to the other flow in the surround region.

  • PDF