• Title/Summary/Keyword: Bubble test

Search Result 206, Processing Time 0.024 seconds

Particle Separation Characteristics and Harvesting Efficiency of Spirulina platensis Using Micro-bubble (미세기포를 이용한 Spirulina platensis의 입자 부상분리 특성 및 수거효율)

  • Gwak, Gyu-Dong;Kim, Mi-Sug;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.5
    • /
    • pp.621-629
    • /
    • 2013
  • Since algae had been issued an environmental problem, water blooms, deepened due to increase of retention water basin in Korea as well as a biomass resource for producing biofuel, this study conducted a series of experiments for Spirulina platensis using the flotation process with micro-bubble. To elevate utilization of collected-algae, this study focused on omitting or minimizing coagulant's doses as changing a cultivation period and condition affected on physical property change of algae. Two coagulants, PAC and Chitosan, were used to test the collecting rate of algae and the result found no difference between two rates. For flotation experiments without adding the coagulant, dried algae weight (passing 14 days after cultivation for 20 days) detected high separation efficiency 98.2 % and it (passing 7 days after long-term cultivation for 28 days) presented good separation efficiency 91.9 %. Chlorophyll's separation efficiency showed a similar tendency with the case of the dried algae weight. In endogeny conditions, a light source and a carbon source were not considerably affected on the flotation separation efficiency. Thus, this study confirms that algae biomass may be collected without the coagulant during the endogeny condition period after enough cultivation time, 3 weeks.

Behavior of boiling heat transfer at coated heating surface(In the range of subatmosptheric pressure) (피복된 전열면에서의 비등특성(대기압 이하의 압력에서))

  • Moon D.Y;Oh S.C.;Yim C.S
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1977
  • This paper describes an experimental investigation which has been carried out with distilled water with the range of heat flux and pressure covering 7,400-28,000kcal/$m^2/h$ and 0.42-1.0332kg/$cm^{2}abs$, respectively. In this experiment, Nickel coated mirror surface heater of 5 cm O.D. was used as a heating source. The conclusions summerized as follows;1. The useful correlation of the test data for the heat transfer coefficient is presented as a function of the pressure. $$a/a_{s}=c{\times}p\;0.18$$ where a is the heat transfer coefficient and $a_s$ is the heat transfer coefficient at atmospheric pressure and p is the pressure, C is constant. 2. The bubble diameter near the heating surface and rising velocity increased with the heat flux. 3. A decrease in pressure results in the decrease of the number of nucleation sites and the increase of the bubble volume. 4. Bubble rising velocity differences are incrased maximumly up to $200\%$ of that at atmopheric pressure.

  • PDF

The Importance of Filter Integrity Test to Ensure Sterility of Radiophamaceuticals for Using PET Image

  • Cho, Yong-Hyun;Park, Jun-Hyung;Hwang, Ki-Young;Kim, Hyung-Woo;Lee, Hong-Jae;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.74-77
    • /
    • 2008
  • The radiopharmaceuticals are routinely injected to blood vessel for acquiring PET image. For this reason, It is imperative that they undergo strict quality control measures. Especially, Sterility test is more important than any other quality control procedures. According to the FDA guideline, It requires filter integrity test used in the processing of sterile solutions. Among several methods, we can decide to use bubble point test. We usually use vented GS-filters (Millipore co., USA) which are sterilizinggrade (0.22 um pore size) and are placed upper site on product vial. After the synthesis of $^{18}F$-FDG, solutions wet the membrane in filter and then go into the product vial. By all synthesis steps have finished, we can observe the presence of the bubbles in the product vial. Since we have started this study, we have never found any bubbles in the product vial. Because the maximum pressure intensity of the filter which has set by manufacturer is up to 5 bars, but helium gas pressure is up to 1 bar in our module system. So, we can make 5 bars pressure using helium gas bombe and increase pressure up to 5 bars step by step. However, it does not happen to anything in vial.

  • PDF

Application of Image Technique and Optical Fiber Sensor for Air-water Mixture Flow (기포흐름 측정을 위한 영상기법 및 광섬유센서 적용)

  • Ryu, Yonguk;Jung, Tae-Hwa
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.7
    • /
    • pp.535-543
    • /
    • 2015
  • Measurements of multiphase flows containing bubbles have been limited because most existing methods target one phase flows. Especially, multiphase flows with a high void ratio have been rarely successful in measurements due to the sudden change of density and thick interfaces between air and water. This study introduces two methods that are capable of measuring flow fields regardless of bubble void ratio, named bubble image velocimetry and bundle fiber optic flow meter. The calculation of the depth of field is suggested to reduce and estimate errors by perspective image velocimetry. The bundle fiber optic flow meter is designed to increase a measurement rate using many optical fibers with a thin diameter. The two methods measured bubble plumes to test reliability and the velocity measurements show good agreement. In addition a hydraulic jump, one of the multiple flows in rivers was measured to test applicability of the methods.

Effect of Air Void and Strength Characteristics with Freezing and Thawing Resistance on High Strength Concrete (고강도(高强度) 콘크리트에서 기포조직(氣泡組織) 및 강도특성(强度特性)이 연결융해저항(連結融解抵抗)에 미치는 영향(影響))

  • Kim, Saeng Bin;Moon, Je Kil;Kim, Dong Sin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.13-24
    • /
    • 1993
  • The influence of the bubble structure and strength characteristics on the freeze-thaw resistance of high strength concrete is investigated by the laboratory experiment. The test conditions are formed in the manner that water is continueusly supplied externally and the specimens were received severe weather actions from ordinary to significantly low temperatures. The experiments are performed in two stages. In the first stage, the relation between the durability to frost action and the bubble structure is analyzed especially with respect to the water-cement ratio and the amount of air. The AE and non-AE concrete specimens made of ordinary portland cement are used in the test. In the second stage, the non-AE concrete specimens using vibratory compaction to improve the durability to frost action, and the high watertight specimens of rapid hardening portland cement to increase their initial strength are produced and tested. The degree of watertightness of the specimens is determined by measuring the permeability of the specimens and the bubble structure of the high watertight concrete is also estimated.

  • PDF

Improvement of Enhanced Assumed Strain Four-node Finite Element Based on Reissner-Mindlin Plate Theory (개선된 추가변형률 4절점 평판휨 요소)

  • Chun, Kyoung Sik;Park, Dae Yong;Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.295-303
    • /
    • 2004
  • In this paper, an improved four-node Reissner-Mindlin plate-bending element with enhanced assumed strain field is presented for the analysis of isotropic and laminated composite plates. To avoid the shear locking and spurious zero energy modes, the transverse shear behavior is improved by the addition of a new enhanced shear strain based on the incompatible displacement mode approach and bubble function. The "standard" enhanced strain fields (Andelfinger and Ramm, 1993) are also employed to improve the in-plane behaviors of the plate elements. The four-node quadrilateral element derived using the first-order shear deformation theory is designated as "14EASP". Several applications are investigated to assess the features and the performances of the proposed element. The results are compared with other finite element solutions and analytical solutions. Numerical examples show that the element is stable, invariant, passes the patch test, and yields good results especially in highly distorted regimes.

Analyses of Overtopping Velocity using Analytical Solution(Ritter's Solution) of Dam-Break Flow (댐 붕괴흐름의 해석해(Ritter의 해)를 이용한 월파유속 분석)

  • Ryu, Yong-Uk;Lee, Jong-In;Kim, Young-Taek
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.7
    • /
    • pp.669-679
    • /
    • 2008
  • The present study examines similarity of behavior between an overtopping wave generated by a plunging wave and a dam-break flow through hydraulic model tests. The dam-break flow has been employed to estimate the overtopping effect on the basis of the dam-break flow's behavior similar to the overtopping. In this study, the overtopping velocity was measured by a modified image technique using bubble and bubble texture images called bubble image velocitmetry. From the measurements, the vertical profiles of horizontal overtopping velocity at cross-sections along the deck were presented and discussed. Maximum velocity and depth-averaged velocity at each cross-section were compared with an analytical solution solving the dam-break flow, Ritter's solution. The initial water depth of importance for the solution was determined from the tested wave condition and the overtopping measurements. The comparison shows that the solution with the initial water depth estimated using the front velocity of the overtopping wave is in good agreements with the measurements.

A Case Study on Field Construction of Cold Weather Mass Concreting Using Double Bubble Sheets and Hydration Heat Difference Method (이중 버블시트 및 수화발열량차 공법에 의한 한중매스콘크리트의 현장적용 연구)

  • Kim Jong;Yoon Jae-Ryung;Jeon Chung-Keun;Shin Dong-An;Oh Seon-Gyo;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.15-18
    • /
    • 2006
  • The test result of mat concrete applying both hydration heat difference and insulation curing method on new construction of Cheongju university educational building are summarized as following. Both fresh concrete and compressive strength properties were satisfied In aimed value. Setting time of concrete incorporating 15% of fly ash(FA) retarded 1.2 hour than control concrete. Temperature history of mali concrete indicated that the highest temperature of center was exhibited at $126^{\circ}C$ after 51 hours while the highest temperature of upper section was $10.6^{\circ}C$ after 46 hours. Temperature Difference between center and surface was managed at less than $6^{\circ}C$ during whole curing period. In addition the temperature of upper section secured more than $3.3^{\circ}C$ while the temperature of outside was indicated at less than $-10^{\circ}C$. Maturity by parts of construction secured more than $30^{\circ}C$ DD higher than outside at 3 days. The more number of times, applying insulation curing method by double bubble sheets, increased, the higher economic effect was secured. Overall it was clear that applying both double bubble sheets and hydration heat difference method on this new construction can resist hydration heat crack, early frost demage and strength decrease. It also significantly contributed quality improvement of cold weather concreting

  • PDF

Enhancement of $NH_3$ Bubble Absorption Performance in Binary Nanofluids (이성분 나노유체에서의 암모니아 기포 흡수 성능 향상)

  • Jung Jun Young;Kim Jin-Kyeong;Kang Yong Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.312-317
    • /
    • 2005
  • The objectives of this paper are to study the absorption characteristics of $NH_3$ bubbles in the binary nanofluids and to quantify the effects of surfactants and nano-particles on the bubble absorption performance. 2-Ethyl-1-Hexanol, n-Octanol, and 2-Octanol are used as the surfactants and nano-sized $Al_{2}O_3$ and Cu particles are added to make the binary nanofluids into $NH_3/H_{2}O$ solution. The concentration of $NH_3$ solution ($x_s$), the concentration of surfactants ($x_{SA}$), and the mass fraction of nano-particles ($w_{np}$) are considered as key parameters. The experimented ranges of $x_s,\;x_{SA},\;and\;w_{np}$ are $0{\sim}17.92\%,\;0{\sim}1,500\;ppm\;and\;0{\sim}0.2\%$, respectively. The absorption rates are calculated by measuring initial and final weights of test section and exposed time. In addition, the bubble absorption processes are visualized using the shadow graphic method. The results show that the absorption performance is significantly enhanced up to 4 times by adding the surfactants and up to 3 times in the binary nanofluids.

Thermal Insulation and Flame Retardant Properties of Cement Based Super Light-weight Inorganic Thermal Insulation using 100㎛ Grade Glass Bubble (100㎛급 글라스 버블 혼입 시멘트계 초경량 무기 단열재의 단열 및 난연특성)

  • Son, Bae-Geun;Song, Hun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.642-649
    • /
    • 2021
  • Energy saving standard for buildings are strengthened, the application of exterior insulation finishing system and thickness of insulation materials are increasing. Most buildings with exterior insulation finishing system is applied organic insulating material. Organic insulating material have workability, economic feasibility, reduction in construction cost, and excellent thermal insulation performance. However, Organic insulating material is very vulnerable to heat, so when a fire occurs, rapid fire spread and toxic gas are generated, causing many casualties. Inorganic insulating material can be non-combustible performance, but it is heavy and has low thermal insulation performance. Mineral wool has higher thermal insulation performance than other types of inorganic insulating material, but mineral wool is disadvantageous to workability and vulnerable to moisture. Glass bubble are highly resistant to water and chemically stable substances. In addition, the density of the glass bubble is very low and the particles are spherical, fluidity is improved by the ball bearing effect. Glass bubbles can be used with cement-based ino rganic insulating material to impro ve the weight and thermal insulatio n perfo rmance o f cement-based inorganic insulation. This study produced a inorganic insulating materials were manufactured using cement-based materials and glass bubble. In order to evaluate the insulation performance and flame retardant performance of cement-based super light-weight inorganic insulating materials using with glass bubble, insulation performance or flame retardant and non-combustible performance were evaluated after manufacturing insulating materials using micro cement and two types of glass bubbles. From the test result, Increasing the mixing ratio of glass bubbles improved the insulation performance of cement-based super light-weight inorganic insulating materials, and when the mixing ratio of glass bubbles was 10%, it sho wed sufficient flame retardant and no n-co mbustible perfo rmance.