• 제목/요약/키워드: Bubble length

검색결과 93건 처리시간 0.025초

수평관 내 물-공기 이상류 거동에 관한 실험적 연구 (An Experimental Investigation on the Behavior of Water-Air Two-phase Flows in a Horizontal Pipe)

  • 조한일;이경수;류시완
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.75-81
    • /
    • 2017
  • A series of laboratory experiments has been performed in order to investigate the behavior of water-air two-phase flow in a horizontal pipe. A conductivity meter has been applied to detect the irregular alternation of air at the specific points in flows. The experimental condition has been established according to the water and air flowrates. Passing time, which is the time length for a measuring probe to pass through the entire length of a specific bubble, has been defined to evaluate the size of bubbles in the flow. Passing length, which can be considered as the equivalent value to bubble size and determined from the product of passing time and cross-sectional averaged velocity, and its corresponding occurrence frequency have been analyzed to classify the air flow patterns according to the condition of air and water fluxes. From the result, the dependancy of flow patterns on the variation of air-water flux ratio has been investigated and the existence of thresholds also checked for classifying the behavior of air in the flow.

익형의 층류박리를 동반한 천이 유동 해석 (COMPUTATION OF TRANSITION FLOW WITH LAMINAR SEPARATION BUBBLE OVER AN AIRFOIL)

  • 전상언;박수형;김상호;변영환;이재우;정경진
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.60-64
    • /
    • 2009
  • Laminar separation bubble and transitional flow over an airfoil are investigated at a moderate range of Reynolds numbers. In this research, a Reynolds-Averaged Navier-Stokes code is coupled with an empirical transition model that can predict transition onset points and the length of transition region. Without solving the boundary layer equations, approximated e-N method is directly applied to the RANS code and iteratively solved together. The computational results are compared with the experimental data for NACA0012 airfoil. Results of transition onset point and length are compared well with experimental and XFOIL prediction. In high angle of attack the present RANS results show better agreement than XFOIL results using the boundary layer equations.

  • PDF

후방 박리기포 감소를 위한 맥동제트의 최적화 연구 (Optimization Study of Pulsating Jet to Reduce the Separation Bubble behind the Fence)

  • 최영호;강인수;김형범
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.53-58
    • /
    • 2008
  • We carried out the experiments which controled the periodic jet in front of the fence to alter the fence wake. The experiments were performed in circulating water channel and the vertical fence was submerged in the boundary layer. The frequency, jet nozzle distance and speed of jet passing the slit were investigated. Each case divided into 20 phases and phase-averaged results were compared with uncontrolled fence flow. From the results, we found the specific frequency and nozzle distance which were good for reducing the reattachment length. In this case, the reattachment length was decreased 35% compared with the uncontrolled fence flow.

원형 디스크 주위 유동에 대한 RANS 유동해석 비교 연구 (Comparative study of flow over a circular disk using RANS turbulence models)

  • 유남규;김병재
    • 한국가시화정보학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2021
  • For a flow normal to a circular disk, the flow separation occurs from the edge of the disk and the flow recirculation zone exists behind the disk. Many existing studies conducted simulations of flow normal to a circular disk under low Reynolds numbers. Some studies performed LES or DES simulations under high Reynolds numbers. However, comparative study for different RANS models for high Reynolds numbers is very limited. This study presents numerical simulations of a flow normal to a circular disk using Realizable k-ε model and SST k-ω model. The recirculation bubble length and drag coefficient were compared with the experimental data. The SST k-ω model showed the excellent predictions for the recirculation bubble length and drag coefficient.

고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계 (A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation)

  • 안예찬;차재은;김무환
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

에어리프트 펌프의 산소 전달 특성에 관한 연구 (Study on The Oxygen Transfer Properties of Airlift Pump)

  • 오세경
    • 한국수산과학회지
    • /
    • 제30권3호
    • /
    • pp.451-458
    • /
    • 1997
  • The oxygen transfer coefficient was not significantly affected by either flow pattern, initial bubble size or the wastes present in the water studied. Surface active substances in the water did however influence the transition from bubble to slug flow. Airlift with length to diameter ratios less than 50 suffered from considerable losses in efficiency. When properly designed, airlift pumping efficiencies were comparable to those of conventional centrifugal pumps and the oxygen transfer efficiency were as high as or higher than those of diffused aeration systems.

  • PDF

Michelson 간섭계를 응용한 미세 상변화 현상 계측 (Probing of Microscale Phase-Change Phenomena Based on Michelson Interforometry)

  • 김동식;박희권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.348-353
    • /
    • 2001
  • Experimental schemes that enable characterization of phase-change phenomena in the micro scale regime is essential for understanding the phase-change kinetics. Particularly, monitoring rapid vaporization on a submicron length scale is an important yet challenging task in a variety of laser-processing applications, including steam laser cleaning and liquid-assisted material ablation. This paper introduces a novel technique based on Michelson interferometry for probing the liquid-vaporization process on a solid surface heated by a KrF excimer laser pulse (${\lambda}=248nm,\;FWHM=24\;ns$) in water. The effective thickness of a microbubble layer has been measured with nanosecond time resolution. The maximum bubble size and growth rate are estimated to be of the order of $0.1{\mu}m\;and\;1\;m/s$, respectively. The results show that the acoustic enhancement in the laser induced vaporization process is caused by bubble expansion in the initial growth stage, not by bubble collapse. This work demonstrates that the interference method is effective for detecting bubble nucleation and microscale vaporization kinetics.

  • PDF

버블시트 피복양생법에 의한 소성 및 건조수축 균열저감 (Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing)

  • 이정교;한천구
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.211-217
    • /
    • 2016
  • 본 연구에서는 2015년 가을철 실제 시공중인 고층 아파트를 대상으로 1중 백색 버블시트로 타설된 콘크리트의 표면을 덮어주는 버블시트 피복양생 공법과 표면을 노출한 채로 양생없이 유지하는 표면노출 방법간을 비교하여 소성 및 건조수축균열의 저감정도를 분석하였다. 실험 결과, 버블시트를 시공하였을 경우, 수화열 및 적산온도는 표면노출보다 약간 높았고, 바닥 균열의 갯수, 길이, 최대 균열폭, 균열 면적 모두 현저하게 적은 값이 측정되었다. 따라서 가을철 버블시트를 타설된 콘크리트 표면에 적용 할 경우에는 소성 및 건조수축균열을 획기적으로 방지할 수 있는 효과적인 표면피복 양생공법인 것으로 판단되었다.

음향교란을 받는 난류박리기포의 이산와류 수치해석 (Discrete-vortex Simulation of Turbulent Separation Bubble Excited by Acoustic Perturbatioons)

  • 임재욱;성형진
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.775-786
    • /
    • 1992
  • 본 연구에서는 DVM의 이론적 배경과 수치계산에 대해 자세히 다루었다. 음향 교란이 가졌을 때의 재부착에 대한 수치해석결과는 Kiya등의 실험결과와 비교하 였으며 만족할만한 일치를 보여주었다. 결과 및 고찰에서는 주로 음향교란이 있는 경우의 재부착길이를 최소화하는 주파수와 교란이 없는 유동의 난류구조해석을 평균속 도 및 압력과 그의 섭동치, 그리고 파워 스펙트럼과 상관계수등을 통해 자세히 비교검 토하였다.

Michelson 간섭계를 응용한 미세 상변화 현상 계측 (Probing of Microscale Phase-Change Phenomena Based on Michelson Interforometry)

  • 김동식;박희권
    • 대한기계학회논문집B
    • /
    • 제25권8호
    • /
    • pp.1140-1147
    • /
    • 2001
  • Experimental schemes that enable characterization of phase-change phenomena in the microscale regime are essential for understanding the phase-change kinetics. Particularly, monitoring rapid vaporization on a submicron length scale is an important yet challenging task in a variety of laser-processing application, including steam laser cleaning and liquid-assisted material ablation. This paper introduces a novel technique based on Michelson interferometry for probing the liquid-vaporization process on a solid surface heated by a KrF excimer laser pulse(λ=248nm, FWHM=24ns) in water. The effective thickness of a microbubble layer has been measured with nanosecond time resolution. The maximum bubble size and growth rate are estimated to be of the order of 0.1㎛ and 1m/s, respectively. The results show that the acoustic enhancement in the laser induced vaporization process is caused by bubble expansion in the initial growth stage, not by bubble collapse. This work demonstrates that the interference method is effective for detecting bubble nucleation and microscale vaporization kinetics.