• Title/Summary/Keyword: Bubble Size

Search Result 322, Processing Time 0.024 seconds

Glass Inclusions in Quartz Phenocrysts of Tuff from Sunshin Au Mining Area, Haenam, Jeonnam. (전남 해남의 순신 금광산 지역에 산출하는 응회질암에 포획된 유리포유물)

  • Lee, Seung-Yeol;Yang, Kyoung-Hee;Jeon, Byung-Geun;Bak, Gil;Koh, Sang-Mo;Seo, Jeong-Ryul
    • The Journal of the Petrological Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.337-348
    • /
    • 2009
  • Clear and homogeneous glass inclusions are well preserved at the rim of the quartz phenocrysts of tuff from Sunshin epithermal Au deposit, Haenam, although the host rocks experienced extensive silicification and argillic alteration. Glass inclusion vary in size from $5\;{\mu}m$ to larger than $200\;{\mu}m$ consisting of glass(60~80 vol%) + vapor bubble(15~30 vol%) $\pm$ daughter crystals(<10 vol%). Most of glass inclusions are cubic to rectangular in shape, indicating that the host quartz grew in the stability field of $\beta$-quartz. All the glass inclusions appear to be primary. Glass inclusions are composed of highly evolved high-K calc-alkaline rhyolites, which can represent the final liquidus phase of the magma system. The $Au_2O_3$ concentration (<0.30 wt%) is trivial in the glass, indicating there was no enrichment in the final residual melt. Textural characteristics suggest that magma was water-saturated shortly before or during the eruption. $H_2O$ content of the glass (ca. 2-4 wt%) suggests a water saturation pressure($P_{H2O}$) of about 300-900 bars. This pressure implies a minimum depth of 0.8-2.5 km for the magma chamber.

Syntheses and Properties of Isosorbide-based Cationic Gemini Surfactants (이소소르비드 기반의 양이온 제미니 계면활성제 합성 및 물성)

  • Cho, Jung-Eun;Jeong, Noh-Hee
    • Applied Chemistry for Engineering
    • /
    • v.31 no.4
    • /
    • pp.429-437
    • /
    • 2020
  • In this study, a cationic gemini surfactant was synthesized using isosorbide, in order to modify the alkyl chain length in the range of C10~C16. The c.m.c and surface tension of the synthesized cationic gemini surfactant were measured to be in the ranges of 5.13 × 10-4~1.62 × 10-4 mol/L and 31.86~37.41 dyne/cm, respectively. The surface tension increased with increasing the length of the alkyl group. In addition, as the area per molecule occupied by the surfactant adsorbed on the interface increased with the reduced extent of adsorption, the bubble generation at the air-water interface decreased. The emulsifying capacity in benzene was maintained above 60 ± 5% after 8 h while that in soybean oil tended to decrease above 50 ± 5%. The performance was superior in benzene, a highly hydrophobic substance, and the emulsion stability was shown to be consistent beyond 1 h during the preparation of pre-emulsion in oil and water. The antimicrobial activity was dependent on the length of the hydrophobic chain of the synthesized cationic gemini surfactant due to the increased size of the clean zone in Escherichia coli (E.coli) and Staphylococcus aureus.

Determinants of Credit Default Swap Spreads: The Case of Korean Firms (한국 기업들의 신용부도스왑 스프레드에 대한 결정요인 분석)

  • Park, Yoon-S.;Kim, Han-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4359-4368
    • /
    • 2011
  • Among several macroeconomic missteps blamed for the recent global financial crisis including the social problems of income distribution and the lack of proper financial remedies, two of them have received particular attention: the global BOP(Balance of Payment) imbalance and the misguided monetary policy. Such BOP imbalance was blamed for massive foreign exchange investment flows from Asia into the U.S., triggering the financial and real estate bubble in America. The latter refers to the excessively loose monetary policy of the U.S. Federal Reserve, which pushed financial institutions and households into reckless investment behavior in search of higher returns. Given the abuse of certain innovative financial techniques and new investment instruments that have been created in recent decades, both collateralized debt obligations (CDOs) and credit default swaps (CDS) enjoyed a symbiotic and toxic relationship prior to the financial crisis This paper is organized as follows: The first section analyzes the real causes of the recent financial crisis. The second details the role of CDOs and CDS. Then, to identify key determinants of the CDS spreads in an emerging capital market, the sample data of major Korean firms' CDS spreads are used to estimate the risk premium by utilizing the multiple regression analysis. The empirical test result indicates that Korean 3-year treasury bond rate(TYIELD), market to book value ratio(MV/BV), and assets size(INASSETS) are shown to demonstrate statistically significant influences on the changes of the CDS premium for sample firms.

A Numerical Study of the Effect of Non-equilibrium Condensation on the Oscillation of Shock Wave in a Transonic Airfoil Flow (비평형 응축이 충격파 진동에 미치는 영향에 관한 수치 해석적 연구)

  • Jeon, Heung Kyun;Kim, In Won;Kwon, Young Doo;Kwon, Soon Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.3
    • /
    • pp.219-225
    • /
    • 2014
  • In this study, to find the characteristics of the oscillation of a terminating shock wave in a transonic airfoil flow with non-equilibrium condensation, a NACA00-12,14,15 airfoil flow with non-equilibrium condensation is investigated through numerical analysis of TVD scheme. Transonic free stream Mach number of 0.81-0.90 with the variation of stagnation relative humidity and airfoil thickness is tested. For the free stream Mach number 0.87 and attack angle of ${\alpha}=0^{\circ}$, the increase in stagnation relative humidity attenuates the strength of the terminating shock wave and inactivates the oscillation of the terminating shock wave. For the case of $M_{\infty}=0.87$ and ${\phi}_0=60%$, the decreasing rate in the frequency of the shock oscillation caused by non-equilibrium condensation to that of ${\phi}_0=30%$ amounts to 5%. Also, as the stagnation relative humidity gets larger, the maximum coefficient of drag and the difference between the maximum and minimum in $C_D$ become smaller. On the other hand, as the thickness of the airfoil gets larger, the supersonic bubble size becomes bigger and the oscillation of the shock wave becomes higher.

Computational Fluid Analysis for the Otter Boards - 3 . Efficiency Analysis of the Single Cambered Otter Boards for the Various Slot Position - (전개판에 대한 수직해법 - 3 . 슬롯에 따른 단순만곡형전개판의 성능분석 -)

  • 고관서
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.4
    • /
    • pp.278-285
    • /
    • 1991
  • The authors propose to use the slot system in order to improve of the efficiency for the cambered otter boards. The experiment is divided into 2 parts, one is the efficiency model test, and the other is the visualization model test. The hydrodynamic characteristics of the model otter boards were tested by efficiency model test to measure the shearing, drag force of the models and visualization test using hydrogen bubble method to observe the streak-line and time-line of flow around the models, and milk spout method to observe the separation zone in the wake behind the models. This study tested for 5 models such ad without slot, slot position 0.2C, 0.4C, 0.6C and 0.8C. The results obtained are as follows: \circled1 The maximum C sub(L) of model otter board with slot position 0.6C in attack angle 27$^{\circ}$ was the highest of all models, it's value was 1.59. \circled2 In general, the L/D ratio of the one slot otter boards were 16~28% higher than otter board without slot. \circled3 The slot position 0.6C was better than any other slot position, and it's conformed by visiualization. \circled4 As to the model otter board with slot position 0.6C, flow speed of the back side was faster 1.3 to 1.7 times than in the front side. \circled5 The size of the separated zone in case of the model otter board with 0.6C was smaller than that of any other models.

  • PDF

A Study on Injection Nozzle and Internal Flow Velocity for Removing Air Bubbles inside the Sample Tanks during Hydraulic Rupture Test (수압파열시험 시 시료 탱크 내부 기포 제거를 위한 주입 노즐 및 내부 유속 연구)

  • Yeseung, Lee;Hyunseok, Yang;Woo-Chul, Jung;Dong Hoon, Lee;Man-Sik, Kong
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.9-15
    • /
    • 2022
  • In order to verify the durability of the high-pressure hydrogen tank in the operating pressure range, a hydraulic rupture test should be performed. However, if the bubbles generated by the initial injection process of water are attached to the inner wall of the tank and remain, a sudden pressure change of the bubbles during the rupture of the pressurized tank may cause shock and noise. Therefore, in this study, the flow velocity required to remove the bubbles remaining on the inner wall of the tank was predicted through simplified formulas, and the shape of the injection nozzle to maintain the flow velocity was determined based on the shape of the hydrogen tank for the hydrogen bus. In addition, a numerical model was developed to predict the change in flow velocity according to the inlet pressure, and an experiment was performed through a model tank to prove the validity of the prediction result. As a result of the experiment, the flow velocity near the tank wall was similar to the predicted value of the analysis model, and when the inlet pressure was 1.5 to 5.5 bar, the minimum size of the removable bubble was predicted to be about 2.2 to 4.6 mm.

Carbon Nanosphere Composite Ultrafiltration Membranes with Anti-Biofouling Properties and More Porous Structures for Wastewater Treatment Using MBRs (분리막 생물반응기를 활용한 폐수처리를 위한 생물오염방지 특성 및 다공성 구조를 가진 탄소나노구체 복합 한외여과막)

  • Jaewoo Lee
    • Membrane Journal
    • /
    • v.34 no.1
    • /
    • pp.38-49
    • /
    • 2024
  • Wastewater treatment using membrane bioreactors has been extensively used to alleviate water shortage and pollution by improving the quality of the treated water discharged into the environment. However, membrane biofouling persistently holds back an MBR process by reducing the process efficiency. Herein, we synthesized carbon nanospheres (CNSs) with many hydrophilic oxygen groups and utilized them as an additive to prepare high-performance ultrafiltration (UF) membranes with hydrophilicity and porous pore structure. CNSs were found to form crescent-shaped pores on the membrane surface, increasing the mean surface pore size by about 40% without causing significant defects larger than bubble points, as the CNS content increased by 4.6 wt%. In addition, the porous pore structure of CNS composite membranes was also attributable to the CNS's isotropic morphologies and relatively low particle number density because the aforementioned properties contributed to preventing the polymer solution viscosity from soaring with the loading of CNS. However, too porous structure compromised the mechanical properties, such that CNS2.3 was the best from a comprehensive consideration including the pore structure and mechanical properties. As a result, CNS2.3 showed not only 2 times higher water permeability than CNS0 but also 5 times longer operation duration until membrane cleaning was required.

Modeling of Scattered Signal from Ship Wake and Experimental Verification (항적 산란신호의 모델링과 실험적 검증)

  • Ji, Yoon-Hee;Lee, Jae-Hoon;Kim, Jea-Soo;Kim, Jung-Hae;Kim, Woo-Shik;Choi, Sang-Moon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.10-18
    • /
    • 2009
  • A moving surface vessel generates a ship wake which contains a cloud of micro-bubbles with radii ranging between $8{\sim}200{\mu}m$. Such micro-bubbles can be detected by active sonar system for more than ten minutes depending on the size and speed of the surface vessel. In this paper, a reverberation model for the ship wake is presented. The developed model consists of the acoustic scattering model due to the distribution of the micro-bubbles and the kinematic model for the moving active sonar. The acoustic scattering model is based on the volume integration, where the volume scattering strengths are obtained from the spatial distribution of micro-bubbles. Since the directivity and look-direction of active sonar are important factors for moving active sonar, the kinematic model utilizes the Euler transformation to obtain the relative motion between the global and local coordinates. In order to verify the developed model, a series of sea experiment was executed in September 2007 to obtain the spatial-temporal distribution of a bubble cloud, and analyzed to be compared with the simulation results.

Open Heart Surgery of Congenital Heart Diseases -Report of Four Cases- (선천성심질환(先天性心疾患)의 심폐기(心肺器) 개심수술(開心手術) - 4례(例) 보고(報告) -)

  • Kim, Kun Ho;Park, Young Kwan;Jee, Heng Ok;Kim, Young Tae;Rhee, Chong Bae;Chung, Yun Chae;Oh, Chull Soo
    • Journal of Chest Surgery
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1976
  • The present. study reports four cases of congenital heart diseases, who received open heart surgery by the Sarn's Heart-Lung-Machine in the department of Thoracic Surgery, Hanyang University Hospital during the period between July 1975 and May 1976. The Heart-Lung-Machine consisted of the Sarn's five head roller pump motor system (model 5000), heat exchanger, bubble trap, the Rygg-Kyvsgaard oxygenator, and monitors. The priming of pump oxygenator was carried out by the hemodilution method using Hartman's solution and whole blood. Of the four cases of the heart diseases, three whose body weight were below 30kg, received the partial hemodilution priming and the remaining one whose body weight was 52kg received the total hemodilution priming with Hartman's solution alone. The rate of hemodilution was in the average of 60.5ml/kg. Extracorporeal circulation was performed at the perfusion flow rate of the average 94.0ml/kg/min, and at the moderate hypothermia between 35'5"C and 30'5"C of the rectal temperature. In the total cardiopulmonary bypass, arterial blood pressure was anged between 30 mmHg and 85 mmHg, generally maintaining over 60 mmHg and venous pressure was measured between 4 and $23cmH_2O$, generally maintaining below $10cmH_2O$. The first case: The patient, a nine year old girl having the symptoms and physical signs typical to cardiac anomaly was definitely diagnosed as isolated pulmonary stenosis through the cardiac catheterization. There was, however, no cyanosis, no pathological finding by X-ray and E.C.G. tracings. The valvulotomy was performed through the arteriotomy of pulmouary artery under the total cardiopulmonary bypass. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The second case: A 12 year old boy with congenital heart anomaly was positively identified as having ventricular septal defect through the cardiac catheterization. As in the case with the first case, the patient exhibited the symptoms and physical signs typical to cardiac anomaly, but no pathological abnormality by X-ray and E.C.G. tracings. The septal defect was localized on atrioventricular canal and was 2 by 10 mm in size. The septal defect was closed by direct simple sutures under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle and pulmonary artery were decreased satisfactory. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The third case: The patient, a 19 year old girl had been experienced the clinical symptoms typical to cardiac anomaly for 16 years. The pink tetralogy of Fallot was definitey diagnosed through the cardiac catheterization. The patient was placed on an ablolute bed rest prior to the operation because of severe exertional dyspnea, fatigability, and frequent syncopal attacks. However, she exhibited very slight cyanosis. Positive findings were noted on E.C.G. tracings and blood picture, but no evidence of pathological abnormality on X-ray was observed. All of the four surgical approaches such as Teflon patch closure (3 by 4cm in size) of ventricular septal defect, myocardial resection of right ventricular outflow tract, valvulotomy of pulmonary valvular stenosis, and pericardial patch closing of ventriculotomy wound were performed in 95 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and murmur and the clinical symptoms disappeared. The fourth case: The patient, a 7 1/4 year old girl had the symptoms of cardiac anomaly for only three years prior to the operation. She was positively identified as having acyanotic tetralogy of Fallot by open heart surgery. The patient showed positive findings by X-ray and E.C.G. tracings, but exhibited no cyanosis and normal blood picture. All of the three surgical approaches, such a myocardial resection of hypertrophic sight ventricular outflow tract, direct suture closing of ventricular septal defect and pericardial patch closing of ventriculotomy wound were carried out in 110 minutes under the cardiopulmonary bypass. Postoperative hemodynamic study revealed that the pressure of the right ventricle was decreased and pulmonary artery was increased satisfactorily. Postoperative course of the patient was uneventful, and the symptoms disappeared.

  • PDF

CT Findings of Bronchogenic Cyst (기관지 낭종의 전산화단층촬영 소견)

  • Cho, Hyun-Cheol;Lee, Yong-Woo;Hwang, Mi-Soo;Cho, Kil-Ho;Byun, Woo-Mok;Cho, Jae-Ho;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.12 no.2
    • /
    • pp.226-236
    • /
    • 1995
  • We studied to evaluate CT characteristics of bronchogenic cysts. We retrospectively evaluated CT of 11 patients with pathologically proved bronchogenic cyst. Precontrast and postcontrast CT scan was performed in all. We analyzed CT with viewpoints of location, size, attenuation on pre- and postcontrast scan, and calcification. Three of 11 bronchogenic cysts were intrapulmonary in location and eight were located in the mediastinum. Two of 3 intrapulmonary bronchogenic cysts were located in the right lower lobe, and the remaining one was left lower lobe. Intrapulmonary bronchogenic cysts ranged from 6cm to 12cm in diameter (average, 9.7 cm). On CT, intrapulmonary bronchogenic cysts appeared as thin-wall air cyst, homogenous water attenuation and soft tissue attenuation with air bubble respectively. Mediastinal bronchogenic cysts were located in posterior mediastinum(n=5), superior mediastinum(n=2), middle mediastinum(n=1) respectively. These cysts ranged in size from 3cm to 8cm in diameter (average, 5.0 cm). On CT, five showed homogenous water attenuation, two soft tissue attenuation similar to that of muscle, one air-fluid level. Calcification or contrast enhancement was not detected in any cases. On operative findings, all of intrapulmonary bronchogenic cysts contained dirty pus-like material and all of mediastinal bronchogenic cysts contained whitish or yellowish mucus material. Bronchogenic cysts showed homogenous water density in many cases, homogenous soft tissue density, air-fluid level and air-filled cyst. The constellation of CT findings may be helpful in the diagnosis and differentiation of bronchogenic cyst.

  • PDF