• 제목/요약/키워드: Bubble Location

검색결과 43건 처리시간 0.026초

MIRA model 후미의 저저항 최적 설계 (Optimal Design for the Low Drag Tail Shape of the MIRA Model)

  • 김욱;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 춘계 학술대회논문집
    • /
    • pp.67-74
    • /
    • 1998
  • Reducing drag of vehicles are the main concern for the body shape designers in order to lower fuel consumption rate and to aid the driving stability. The drag of bluff bodies like transportation vehicles is mostly pressure drag due to the flow separation, which can minimized by controlling the location and size of the separation bubble. In the present study, the TURBO-3D code is incorporated with optimal algorithm based on analytical approximation method to obtain optimal afterbody shape of the MIRA Model corresponding to the lowest drag coefficient. For this purpose three mutually independent afterbody angles are chosen as design variables, while the drag coefficient is chosen as an objective function. It is demonstrated in the present study that an optimal body shape having lowest drag coefficient which is about $6\%$ lower than that of the original shape has been successfully obtained within number of iterations of the optimal design loop.

  • PDF

난류 경계층에 잠긴 수직벽 주위 유동의 2차원성 연구 (Experimental Investigation of Two-dimensionality of Flow around the Vertical Fence Submerged in a Turbulent Boundary Layer)

  • 차재은;김형우;김형범
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.13-18
    • /
    • 2010
  • An experimental investigation of the flow around a vertical fence was carried out using a PIV velocity field measurement technique. The vertical fence was embedded in a turbulent boundary layer. The instantaneous velocity fields measured at cross-sectional planes reveal complex longitudinal vortices that vary in size and strength, developing from the upstream location. In the instantaneous vorticity and velocity field data, the shear flow separated from the fence top is highly turbulent and shows unsteady flow characteristics. The topography of the ensemble averaged velocity fields, especially the separation bubble formed behind the fence, shows that the spatial distributions of streamwise velocity (U) and vertical (V) are symmetric, the spanwise velocity (W) is skew-symmetric with respect to the central xy-plane(z=0).

실내 기류패턴에 따른 급기효율과 배기효율의 분포 (Distributions of Local Supply and Exhaust Effectiveness according to the Room Airflow Patterns)

  • 한화택;최선호;장경진
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.853-859
    • /
    • 2001
  • A pulsed tracer gas technique is applied to measure distributions of local mean age and residual life time of air in a half-scale experimental chamber. The room airflow patterns are flow-visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is either at bottom-left(Case 1), bottom-right(Case 2), or top-left(Case 3) location. Results show that the distribution of LMA and LMR are different from each other, but both of them are closely related to the airflow pattern in the space. Results on overall room ventilation effectiveness are provided depending upon ventilation airflow rates for three different supply-exhaust configurations.

  • PDF

Distributions of Local Supply and Exhaust Effectiveness according to Room Airflow Patterns

  • Han, Hwa-Taik;Choi, Sun-Ho;Lee, Woo-Won
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권4호
    • /
    • pp.177-183
    • /
    • 2002
  • A pulsed tracer gas technique is applied to measure the distributions of local mean age and local mean residual-life-time of air in a half-scale experimental chamber, The airflow patterns in the chamber are visualized by a Helium bubble generator for three different exhaust locations. A supply slot is located at the top of a right wall, and an exhaust slot is at either bottom-left (Case 1), bottom-right (Case 2), or top-left (Case 3) location. Results show that the distributions of local mean age and local mean residual-life-time are different from each other, but both of them are closely related to the airflow pattern in the space. Included are discussions on explaining the variations of overall room ventilation effectiveness depending upon airflow rates for three different supply-exhaust configurations.

펌프의 작동요인에 따른 흐름주입식 바이오센서의 성능 검증 (Performance Evaluation of Flow Injection Type Biosensor According to Operating Variables of Pump)

  • 송대빈;정효석;이승규
    • Journal of Biosystems Engineering
    • /
    • 제30권5호
    • /
    • pp.312-317
    • /
    • 2005
  • A flow injection type biosensor was tested to confirm the performance of a batch and a continuous type flow injection unit. Reproducibility and consistence of the biosensor were investigated to determine the effect of pulsations and air bubbles, and the applicability of on-line monitoring. The air bubbles affected the performance of the sensor irrespective of the location, and also the pulsations of the pump influenced the performance of the sensor. The applicability of on-line motoring was accepted as the result of the repeated and long-term measurements.

Pseudo-compressibility 방법에서 이상유동 해석을 위한 Level Set방법의 적용 (Level Set Method Applied on Pseudo-compressibility Method for the Analysis of Two-phase Flow)

  • 임승원;김종암;심재설;이동영
    • 한국해안해양공학회지
    • /
    • 제17권3호
    • /
    • pp.158-165
    • /
    • 2005
  • Level Set방법을 사용하여 액체와 기체의 서로 다른 상을 함께 해석하는 연구를 수행하였다. Level Set함수는 상의 경계면에서부터 부호를 갖는 거리함수로 정의되며,계산 격자에서 함수 값의 부호에 따라 각 상을 구분하고 물성치를 부여한다. 본 논문에서는 비압축성 유체의 보존식에 Level Set함수의 이동식을 연계하여 이상유동을 모사하는 지배방정식을 구성하였으며, 이를 pseudo-compressibility 방법으로 함께 풀었다. 이 때 다양한 문제에 적용이 가능하도록 일반 곡선 좌표계에서 식을 유도하였고, 수치해석을 위한 행렬식들을 함께 유도하였다. 개발된 해석 코드를 표면장력이 있는 기포 동역학 문제와 수중익에 의한 파도 발생 문제에 적용하여 타당한 결과를 얻을 수 있었다.

Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings

  • Gol-Zaroudi, Hamzeh;Aly, Aly-Mousaad
    • Wind and Structures
    • /
    • 제25권3호
    • /
    • pp.233-259
    • /
    • 2017
  • Investigations on simulated near-surface atmospheric boundary layer (ABL) in an open-jet facility are carried out by conducting experimental tests on small-scale models of low-rise buildings. The objectives of the current study are: (1) to determine the optimal location of test buildings from the exit of the open-jet facility, and (2) to investigate the scale effect on the aerodynamic pressure characteristics. Based on the results, the newly built open-jet facility is well capable of producing mean wind speed and turbulence profiles representing open-terrain conditions. The results show that the proximity of the test model to the open-jet governs the length of the separation bubble as well as the peak roof pressures. However, test models placed at a horizontal distance of 2.5H (H is height of the wind field) from the exit of the open-jet, with a width that is half the width of the wind field and a length of 1H, have consistent mean and peak pressure coefficients when compared with available results from wind tunnel testing. In addition, testing models with as large as 16% blockage ratio is feasible within the open-jet facility. This reveals the importance of open-jet facilities as a robust tool to alleviate the scale restrictions involved in physical investigations of flow pattern around civil engineering structures. The results and findings of this study are useful for putting forward recommendations and guidelines for testing protocols at open-jet facilities, eventually helping the progress of enhanced standard provisions on the design of low-rise buildings for wind.

Numerical investigation of turbulence models with emphasis on turbulent intensity at low Reynolds number flows

  • Musavir Bashir;Parvathy Rajendran;Ambareen Khan;Vijayanandh Raja;Sher Afghan Khan
    • Advances in aircraft and spacecraft science
    • /
    • 제10권4호
    • /
    • pp.303-315
    • /
    • 2023
  • The primary goal of this research is to investigate flow separation phenomena using various turbulence models. Also investigated are the effects of free-stream turbulence intensity on the flow over a NACA 0018 airfoil. The flow field around a NACA 0018 airfoil has been numerically simulated using RANS at Reynolds numbers ranging from 100,000 to 200,000 and angles of attack (AoA) ranging from 0° to 18° with various inflow conditions. A parametric study is conducted over a range of chord Reynolds numbers for free-stream turbulence intensities from 0.1 % to 0.5 % to understand the effects of each parameter on the suction side laminar separation bubble. The results showed that increasing the free-stream turbulence intensity reduces the length of the separation bubble formed over the suction side of the airfoil, as well as the flow prediction accuracy of each model. These models were used to compare the modeling accuracy and processing time improvements. The K- SST performs well in this simulation for estimating lift coefficients, with only small deviations at larger angles of attack. However, a stall was not predicted by the transition k-kl-omega. When predicting the location of flow reattachment over the airfoil, the transition k-kl-omega model also made some over-predictions. The Cp plots showed that the model generated results more in line with the experimental findings.

안면부 농양 및 골염으로 오인된 나무 이물 1례 (A Case of Wooden Foreign Body Misinterpreted as Facial Abscess and Osteitis)

  • 김은서;김영철;김석천;홍석찬
    • 대한두경부종양학회지
    • /
    • 제16권2호
    • /
    • pp.235-237
    • /
    • 2000
  • It is difficult to find the penetrating foreign bodies in the head and neck area only with history taking and physical examinations. One of the most important things is to detect the precise location of foreign bodies or possibly remained materials. The detection of wooden foreign bodies is important because they can cause phlegmon formation and because wood is often contaminated by Clostridium tetani bacteria. CT has proved to be an expedient method for detecting foreign bodies of various materials in soft tissues, but the wooden foreign body is often misinterpreted as a gas bubble in soft tissue. We have experienced a case of wooden foreign body which has penetrated through nasal dorsum and remained for 4 months. It had been initially misinterpreted as longstanding inflammatory lesion and osteitis of maxilla and nasal bone.

  • PDF

Motor Weakness after Caudal Epidural Injection Using the Air-acceptance Test

  • Lee, Mi Hyeon;Han, Cheol Sig;Lee, Sang Hoon;Lee, Jeong Hyun;Choi, Eun Mi;Choi, Young Ryong;Chung, Mi Hwa
    • The Korean Journal of Pain
    • /
    • 제26권3호
    • /
    • pp.286-290
    • /
    • 2013
  • Air injected into the epidural space may spread along the nerves of the paravertebral space. Depending on the location of the air, neurologic complications such as multiradicular syndrome, lumbar root compression, and even paraplegia may occur. However, cases of motor weakness caused by air bubbles after caudal epidural injection are rare. A 44-year-old female patient received a caudal epidural injection after an air-acceptance test. Four hours later, she complained of motor weakness in the right lower extremity and numbness of the S1 dermatome. Magnetic resonance imaging showed no anomalies other than an air bubble measuring 13 mm in length and 0.337 ml in volume positioned near the right S1 root. Her symptoms completely regressed within 48 hours.