• 제목/요약/키워드: Bubble Discharge

검색결과 52건 처리시간 0.029초

액체 $SF_6$의 기포발생과 거동에 따른 절연파괴특성 (The Discharge Characteristics through the Bubble Production & Motion in Liquid $SF_6$)

  • 최은혁;최상태;박원주;김이국;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.39-43
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

액체 $SF_6$의 정기포현상(正氣泡現像) (The positive bubble effect in liquid $SF_6$)

  • 최은혁;이재학;박광서;김종환;김이국;박원주;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.151-154
    • /
    • 2005
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and liquid $SF_6$ in model GIS(Gas Insulated Switchgear) were described. From this results, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in model GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble caused by high electric emission. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

  • PDF

고온초전도코일 모의전극계에서 기포거동 및 부분방전개시전압의 추정 (Estimation of Bubble Behavior and PD Initiation Voltage in the Simulated Electrode System of High Temperature Superconducting Coils)

  • 석복렬;최명준;김용한;김진수;김종구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1771-1773
    • /
    • 2001
  • This paper deals with the numerical estimation of the bubble behavior and the partial discharge(PD) initiation voltage basis of electric field calculation with the coaxial coil layer-to-cylindrical electrode system for the simulation of high temperature superconducting coils. The theoretical results of bubble behavior and the PD initiation voltages showed fairly good agreements with the experimental results.

  • PDF

액체 $SF_6$의 전극별 기포유동현상과 절연파괴특성 (The discharge characteristics & Bubble Movement for various electrode shapes in Liquid $SF_6$)

  • 최은혁;임창호;장승호;김이국;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.252-253
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

An Experimental Study on the Temperature Distribution in IRWST

  • Kim, Sang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • 제18권5호
    • /
    • pp.820-829
    • /
    • 2004
  • The In-Containment Refueling Water Storage Tank (IRWST), one of the design improvements applied to the APR -1400, has a function to condense the high enthalpy fluid discharged from the Reactor Coolant System (RCS). The condensation of discharged fluid by the tank water drives the tank temperature high and causes oscillatory condensation. Also if the tank cooling water temperature approaches the saturated state, the steam bubble may escape from the water uncondensed. These oscillatory condensation and bubble escape would burden the undue load to the tank structure, pressurize the tank, and degrade its intended function. For these reasons simple analytical modeling and experimental works were performed in order to predict exact tank temperature distribution and to find the effective cooling method to keep the tank temperature below the bubble escape limit (93.3$^{\circ}C$), which was experimentally proven by other researchers. Both the analytical model and experimental results show that the temperature distributions are horizontally stratified. Particularly, the hot liquid produced by the condensation around the sparger holes goes up straight like a thermal plume. Also, the momentum of the discharged fluid is not so strong to interrupt this horizontal thermal stratification significantly. Therefore the layout and shape of sparger is not so important as long as the location of the sparger hole is sufficiently close to the bottom of the tank. Finally, for the effective tank cooling it is recommended that the locations of the discharge and intake lines of the cooling system be cautiously selected considering the temperature distribution, the water level change, and the cooling effectiveness.

$SF_6$와 액체 질소의 절연파괴특성과 정기포현상 (The Positive Bubble Effect and the Breakdown Characteristics in $SF_6$ and $LN_2$)

  • 이광식;최은혁;박광서;김종환;임창호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.355-360
    • /
    • 2005
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas, $SF_6$ liquid ($LSF_6$) and $N_2$ liquid ($LN_2$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, the breakdown voltage of $SF_6$ increases with the drop of temperature and the increase of the inner pressure in model GIS. The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas and $LN_2$. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machine교 which will be studied and developed in the future.

(-)전압 인가시 액체 $SF_6$의 전극형상에 따른 절연파괴특성 (The discharge characteristics for various electrode shapes under negative high-voltagein in Liquid $SF_6$)

  • 최은혁;박광서;김이국;이광식;도대호;김종환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2085-2087
    • /
    • 2005
  • In this paper the experiments of insulation characteristics by temperature change of $SF_6$ gas and liquid $SF_6$ in model GIS(Gas Insulated Switchgear) were described. From this results, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in model GIS. The ability of insulation in liquid $SF_6$ was higher than that of the highly pressurized $SF_6$ gas. A liquid $SF_6$ discharge characteristics was caused by bubble formed evaporation of liquid $SF_6$ and bubble caused by high electric emission. It is considered that these result are fundamental data for electric insulation design of superconductor and cryogenic application machinery which will be studied and developed in the future.

  • PDF

77K 이하 극저온 상에서의 부분방전 특성 분석 (Analysis of Partial Discharge Characteristics at Cryogenic Temperature below 77K)

  • 이상화;김복렬;신우주;이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1562-1563
    • /
    • 2011
  • Partial discharge measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. Recently partial discharge diagnostic techniques were also utilized to evaluate the cryogenic dielectric insulation of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used used as the cryogenic and dielectric media for many high temperature superconducting high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric properties of the liquid nitrogen. So in order to reduce the bubble formation, subcooled nitrogen was also employed for this purpose. In this work, investigation of partial discharge characteristics of subcooled liquid nitrogen were conducted in order to clarify the retardation of partial discharge initiation voltage according to the different subcooling temperature of liquid nitrogen. And also the relation of partial discharge phenomena and the activities of bubbles were analyzed. It was observed that PD inception voltages shows rather different characteristics according to the decrease of subcooling temperature and the activities of bubbles were strongly influenced by temperature of the subcooled liquid nitrogen.

  • PDF

난류전단 흐름에서의 기포응집에 관한 수치모의: 2. 모형의 적용 (Numerical Simulation of the Coalescence of Air Bubbles in Turbulent Shear Flow: 2. Model Application)

  • 전경수
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1365-1373
    • /
    • 1994
  • 난류전단 흐름에서의 기포 크기분포를 예측하기 위하여 개발된 Monte-Carlo 모의모형을 실험실 크기의 문제에 적용하였다. 각종 모형 매개변수 및 물리적 변수들에 대한 민감도 분석을 수행하였으며, 실험 관측치와의 비교를 통하여 모형의 실제 적용성에 관하여 조사하였다. 공기와 물의 유량비 또는 마찰계수가 증가함에 따라 기포의 크기가 커지는 것으로 나타났다. 평균유속이 증가함에 따라 가포의 크기는 작아지지만, 폭기구간내 기포의 총표면적은 거의 일정함을 보였다. 모형의 종방향 거리증분에 따른 기포 크기분포의 변화는 거의 없었으며, 횡방향 거리중분을 크게 할수록 기포가 크거나 작은 쪽으로 치우쳐 중간정도의 크기를 갖는 기포의 수가 감소하였다. 기포의 크기분포는 그 초기분포 및 공기의 주입위치에 크게 영향을 받는 것으로 나타났다. 기포의 충돌과 응집을 구분하기 위하여 충돌효율을 도입하였다.

  • PDF

Prediction of Cavitation Intensity in Pumps Based on Propagation Analysis of Bubble Collapse Pressure Using Multi-Point Vibration Acceleration Method

  • Fukaya, Masashi;Ono, Shigeyoshi;Udo, Ryujiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권2호
    • /
    • pp.165-171
    • /
    • 2009
  • We developed a 'multi-point vibration acceleration method' for accurately predicting the cavitation intensity in pumps. Pressure wave generated by cavitation bubble collapse propagates and causes pump vibration. We measured vibration accelerations at several points on a casing, suction and discharge pipes of centrifugal and mixed-flow pumps. The measured vibration accelerations scattered because the pressure wave damped differently between the bubble collapse location and each sensor. In a conventional method, experimental constants are proposed without evaluating pressure propagation paths, then, the scattered vibration accelerations cause the inaccurate cavitation intensity. In our method, we formulated damping rate, transmittance of the pressure wave, and energy conversion from the pressure wave to the vibration along assumed pressure propagation paths. In the formulation, we theoretically defined a 'pressure propagation coefficient,' which is a correlation coefficient between the vibration acceleration and the bubble collapse pressure. With the pressure propagation coefficient, we can predict the cavitation intensity without experimental constants as proposed in a conventional method. The prediction accuracy of cavitation intensity is improved based on a statistical analysis of the multi-point vibration accelerations. The predicted cavitation intensity was verified with the plastic deformation rate of an aluminum sheet in the cavitation erosion area of the impeller blade. The cavitation intensities were proportional to the measured plastic deformation rates for three kinds of pumps. This suggests that our method is effective for estimating the cavitation intensity in pumps. We can make a cavitation intensity map by conducting this method and varying the flow rate and the net positive suction head (NPSH). The map is useful for avoiding the operating conditions having high risk of cavitation erosion.