• 제목/요약/키워드: Bruno technique

검색결과 12건 처리시간 0.02초

치근피개술의 임상적 효과 비교 (A Comparison of Clinical Effect for Root Coverage)

  • 한종수;홍기석;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제38권3호
    • /
    • pp.483-492
    • /
    • 2008
  • Purpose: The purpose of this study was to compare clinical effect of the Langer & Langer technique, the modified Langer & Langer technique and Bruno technique. Material and Methods: 30 patients who have gingiva recession(Miller class I or class II) were carried root coverage. Langer & Langer technique(14 patients/32 tooth), modified Langer & Langer technique(5 patients/10 tooth) and Bruno technique(11 patients/18 tooth) was carried. At baseline and average 3 months after operation, it was estimated clinical index(Pocket depth, gingiva recession, clinical attachment level, keratinized gingiva, scar tissue, root coverage rate) by Williams style probe. Result: Root coverage rate is indicated Langer & Langer technique(8S%), Modified Langer & Langer technique(86%) and Bruno technique(90%). Conclusion: All three of the procedures were effective in gingival recession and improved clinical parameters.

Small scale experimental testing to verify the effectiveness of the base isolation and tuned mass dampers combined control strategy

  • Petti, Luigi;Giannattasio, Giovanni;De Iuliis, Massimiliano;Palazzo, Bruno
    • Smart Structures and Systems
    • /
    • 제6권1호
    • /
    • pp.57-72
    • /
    • 2010
  • This paper presents the most significant results obtained within a broad-ranging experimental program aiming to evaluate both the effectiveness and the robustness of a Base Isolation (BIS) and a Tuned Mass Damper (TMD) combined control strategy (BI & TMD). Following a brief description of the experimental model set-up and the adopted kinematic scaling technique, this paper describes the identification procedures carried out to characterize the system''s model. The dynamic response of a small-scale model to recorded earthquake excitations, which has been scaled by using the Buckingham pi-theorem, are later presented and discussed. Finally, the effectiveness and robustness of the combined control strategy is evaluated by comparing the model's dynamic response. In particular, reduction in relative displacements and absolute accelerations due to the application of different mass damping systems is investigated.

Simplified method to design laterally loaded piles with optimum shape and length

  • Fenu, Luigi;Briseghella, Bruno;Marano, Giuseppe Carlo
    • Structural Engineering and Mechanics
    • /
    • 제71권2호
    • /
    • pp.119-129
    • /
    • 2019
  • Optimum shape and length of laterally loaded piles can be obtained with different optimization techniques. In particular, the Fully Stress Design method (FSD) is an optimality condition that allows to obtain the optimum shape of the pile, while the optimum length can be obtained through a transversality condition at the pile lower end. Using this technique, the structure is analysed by finite elements and shaped through the FSD method by contemporarily checking that the transversality condition is satisfied. In this paper it is noted that laterally loaded piles with optimum shape and length have some peculiar characteristics, depending on the type of cross-section, that allow to design them with simple calculations without using finite element analysis. Some examples illustrating the proposed simplified design method of laterally loaded piles with optimum shape and length are introduced.

READY MADE디자이너를 위한 창조적인 훈련 연구 (READY MADE Creative Gymnastic for Designers)

  • 마르코 부르노
    • 디자인학연구
    • /
    • 제19권2호
    • /
    • pp.365-374
    • /
    • 2006
  • '레디 메이드' (Ready made)란 예술로 선택 제안된 일상의 사물들을 의미한다. 이 용어는 예술적 오브제가 지닌 특수성을 파괴하고자 하였던 뒤샹의 창작과정에서 만들어졌는데 예술세계를 넘어 창의성을 기초로 하는 모든 디자인 영역에 영향을 끼쳤다. 본 연구의 목적은 교육적 관점에서 '레디 메이의'(Ready made)방법 고찰에 있다. 뒤샹의 경험과 그가 디자인 세계에 끼친 영향을 시작으로. 본 연구는 교육적인 관점으로서 레디메이드 방법론적인 테크닉을 연구하였다. 이 연구 방법은 서로 다른 여러 대학의 40명의 학생들에게 프로젝트를 임명하여 나온 경험적인 관찰의 결과를 토대로 하였다. 수집된 결과는 구성적, 개념적, 집합적, 정교적, 각각의 구체적 특성이 있는 방법에 따라 4가지로 분류하였다. 관찰의 결과에 따라 나뉜 4가지 카테고리는 같은 방법으로 훈련되어진 기술의 다양함이 실체적으로 표현되었다. 이것은 젊은 디자이너들을 위해 특별하게 제안된 기본적인 연습으로서 레이디 메이드 기법이 지닌 가치를 유연성 있게 보여주고자 하였다. 아이디어에 중점을 둔 일상의 오브젝트의 새로운 정체성과 재활용의 관심, 재인식, 탐구에 의해 디자인된 프로젝트의 관련을 통해 학생들의 중요한 기술이 발전되었다.

  • PDF

Maxillary first molar with 7 root canals diagnosed using cone-beam computed tomography

  • Rodrigues, Evaldo;Braitt, Antonio Henrique;Galvao, Bruno Ferraz;da Silva, Emmanuel Joao Nogueira Leal
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.60-64
    • /
    • 2017
  • Root canal anatomy is complex, and the recognition of anatomic variations could be a challenge for clinicians. This case report describes the importance of cone beam computed tomographyic (CBCT) imaging during endodontic treatment. A 23 year old woman was referred by her general dental practitioner with the chief complaint of spontaneous pain in her right posterior maxilla. From the clinical and radiographic findings, a diagnosis of symptomatic irreversible pulpitis was made and endodontic treatment was suggested to the patient. The patient underwent CBCT examination, and CBCT scan slices revealed seven canals: three mesiobuccal (MB1, MB2, and MB3), two distobuccal (DB1 and DB2), and two palatal (P1 and P2). Canals were successfully treated with reciprocating files and filled using single-cone filling technique. Precise knowledge of root canal morphology and its variation is important during root canal treatment. CBCT examination is an excellent tool for identifying and managing these complex root canal systems.

Augmented reality and dynamic infrared thermography for perforator mapping in the anterolateral thigh

  • Cifuentes, Ignacio Javier;Dagnino, Bruno Leonardo;Salisbury, Maria Carolina;Perez, Maria Eliana;Ortega, Claudia;Maldonado, Daniela
    • Archives of Plastic Surgery
    • /
    • 제45권3호
    • /
    • pp.284-288
    • /
    • 2018
  • Dynamic infrared thermography (DIRT) has been used for the preoperative mapping of cutaneous perforators. This technique has shown a positive correlation with intraoperative findings. Our aim was to evaluate the accuracy of perforator mapping with DIRT and augmented reality using a portable projector. For this purpose, three volunteers had both of their anterolateral thighs assessed for the presence and location of cutaneous perforators using DIRT. The obtained image of these "hotspots" was projected back onto the thigh and the presence of Doppler signals within a 10-cm diameter from the midpoint between the lateral patella and the anterior superior iliac spine was assessed using a handheld Doppler device. Hotspots were identified in all six anterolateral thighs and were successfully projected onto the skin. The median number of perforators identified within the area of interest was 5 (range, 3-8) and the median time needed to identify them was 3.5 minutes (range, 3.3-4.0 minutes). Every hotspot was correlated to a Doppler sound signal. In conclusion, augmented reality can be a reliable method for transferring the location of perforators identified by DIRT onto the thigh, facilitating its assessment and yielding a reliable map of potential perforators for flap raising.

Production of transgenic cattle by somatic cell nuclear transfer (SCNT) with the human granulocyte colony-stimulation factor (hG-CSF)

  • Carvalho, Bruno P.;Cunha, Andrielle T.M.;Silva, Bianca D.M.;Sousa, Regivaldo V.;Leme, Ligiane O.;Dode, Margot A.N.;Melo, Eduardo O.
    • Journal of Animal Science and Technology
    • /
    • 제61권2호
    • /
    • pp.61-68
    • /
    • 2019
  • The hG-CSF (human Granulocyte Colony-Stimulating Factor) is a growth and stimulation factor capable of inducing the proliferation of bone marrow cells, several types of leukocytes, among other hematopoietic tissue cells. hG-CSF is used in used to treat anomalies that reder a small number of circulating white blood cells, which may compromise the immune defenses of the affected person. For these reasons, the production of hG-CSF in a bioreactor system using the mammary gland of genetic modified animals is a possibility of adding value to the bovine genetic material and reducing the costs of hG-CSF production in pharmaceutical industry. In this study, we aimed the production of transgenic hG-CSF bovine through the lipofection of bovine primary fibroblasts with an hG-CSF expression cassette and cloning these fibroblasts by the somatic cell nuclear transfer (SCNT) technique. The bovine fibroblasts transfected with the hG-CSF cassette presented a stable insertion of this construct into their genome and were efficiently synchronized to G0/G1 cell cycle stage. The transgenic fibroblasts were cloned by SCNT and produced 103 transferred embryos and 2 pregnancies, one of which reached 7 months of gestation.

Effectiveness of endodontic retreatment using WaveOne Primary files in reciprocating and rotary motions

  • Patricia Marton Costa;Renata Maira de Souza Leal;Guilherme Hiroshi Yamanari;Bruno Cavalini Cavenago;Marco Antonio Hungaro Duarte
    • Restorative Dentistry and Endodontics
    • /
    • 제48권2호
    • /
    • pp.15.1-15.7
    • /
    • 2023
  • Objectives: This study evaluated the efficiency of WaveOne Primary files (Dentsply Sirona) for removing root canal fillings with 2 types of movement: reciprocating (RCP) and continuous counterclockwise rotation (CCR). Materials and Methods: Twenty mandibular incisors were prepared with a RCP instrument (25.08) and filled using the Tagger hybrid obturation technique. The teeth were retreated with a WaveOne Primary file and randomly allocated to 2 experimental retreatment groups (n = 10) according to movement type: RCP and CCR. The root canals were emptied of filling material in the first 3 steps of insertion, until reaching the working length. The timing of retreatment and procedure errors were recorded for all samples. The specimens were scanned before and after the retreatment procedure with micro-computed tomography to calculate the percentage and volume (mm3) of the residual filling material. The results were statistically evaluated using paired and independent t-tests, with a significance level set at 5%. Results: No significant difference was found in the timing of filling removal between the groups, with a mean of 322 seconds (RCP) and 327 seconds (CCR) (p < 0.05). There were 6 instrument fractures: 1 in a RCP motion file and 5 in continuous rotation files. The volumes of residual filling material were similar (9.94% for RCP and 15.94% for CCR; p > 0.05). Conclusions: The WaveOne Primary files used in retreatment performed similarly in both RCP and CCR movements. Neither movement type completely removed the obturation material, but the RCP movement provided greater safety.

Optimizing Fat Grafting Using a Hydraulic System Technique for Fat Processing: A Time and Cost Analysis

  • Verdura, Vincenzo;Guastafierro, Antonio;Di Pace, Bruno;Faenza, Mario;Nicoletti, Giovanni Francesco;Rubino, Corrado
    • Archives of Plastic Surgery
    • /
    • 제49권2호
    • /
    • pp.266-274
    • /
    • 2022
  • Background Many authors have researched ways to optimize fat grafting by looking for a technique that offers safe and long-term fat survival rate. To date, there is no standardized protocol. We designed a "hydraulic system technique" optimizing the relationship among the quantity of injected fat, operative time, and material cost to establish fat volume cutoffs for a single procedure. Methods Thirty-six patients underwent fat grafting surgery and were organized into three groups according to material used: standard, "1-track," and "2-tracks" systems. The amount of harvested and grafted fat as well as material used for each procedure was collected. Operating times were recorded and statistical analysis was performed to establish the relationship with the amount of treated fat. Results In 15 cases the standard system was used (mean treated fat 72 [30-100] mL, mean cost 4.23 ± 0.27 euros), in 11 cases the "1-track" system (mean treated fat 183.3 [120-280] mL, mean cost 7.63 ± 0.6 euros), and in 10 cases the "2-tracks" one (mean treated fat 311[220-550] mL, mean cost 12.47 ± 1 euros). The mean time difference between the standard system and the "1-track" system is statistically significant starting from three fat syringes (90 mL) in 17.66 versus 6.87 minutes. The difference between the "1-track" system and "2-tracks" system becomes statistically significant from 240 mL of fat in 15 minutes ("1-track") versus 9.3 minutes for the "2-tracks" system. Conclusion Data analysis would indicate the use of the standard system, "1-track," and "2-tracks" to treat an amount of fat < 90 mL of fat, 90 ÷ 240 mL of fat, and ≥ 240 mL of fat, respectively.