• Title/Summary/Keyword: Broker Platform

Search Result 33, Processing Time 0.021 seconds

Gateway platform for interoperability between OPC UA Publisher and DDS Subscribers (OPC UA Publisher와 DDS Subscriber의 상호운용성을 위한 게이트웨이 플랫폼)

  • Sim, Woong-Bin;Song, Byung-Kwen;Shin, Jun-Ho
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.291-301
    • /
    • 2021
  • OPC UA at the control and field level does not provide enough performance to replace the field bus. The OPC Foundation aims for a real-time and connection-less mechanism, and has added the OPC UA publish-subscribe model, a new specification that supports broker functions such as MQTT and AMQP, as the OPC UA Part 14 standard. This paper is about a gateway for interoperability between OPC UA publisher with the addition of OPC UA Part14 standard and DDS subscribers. Raspberry Pi 4 is used for the gateway proposed in this paper, and OpenDDS, an open source, is used for DDS. OPC UA publish-subscribe module used A-Open62541 publish-subscribe module, which additionally implements functions not provided by the corresponding source based on Open62541 publish-subscribe open source.

Integrity Guarantee System in IoT Virtual Environment Platform: Through Hyperedfger Indy and MQTT (IoT 가상환경 플랫폼에서의 무결성 보장 시스템:Hyperledger Indy와 MQTT를 통하여)

  • Yoosung Hong;Geun-Hyung Kim
    • Smart Media Journal
    • /
    • v.13 no.4
    • /
    • pp.76-85
    • /
    • 2024
  • In this paper, we propose a system that improves the data integrity of IoT(Internet of Things) devices in the virtual environment by combining Hyperledger Indy and MQTT(Message Queuing Telemetry Transport). The system complements the limitations of the centralized system by realizing a DPKI(Decentralized Public Key Infrastructure) structure that utilizes a distributed network in publish-subscribe(pub/sub) pattern communication. Digital signature technology was applied to ensure the data integrity of IoT devices and communication scenarios between the four core components of the client, IoT device, broker, and blockchain, as well as a topic structure using a decentralized identifier to ensure safety in the virtual environment. We present a systematic method for transparent data exchange. To prove the performance of the proposed system, this paper conducted experiments on four scenarios and evaluated communication performance in a virtual environment. The experimental results confirmed that the proposed system provides a reliable IoT data communication structure in a virtual environment.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF