• Title/Summary/Keyword: Broad spectrum

Search Result 855, Processing Time 0.044 seconds

Eliashberg Calculation of the Momentum-Resolved Self-Energy for the Cuprate Superconductors Induced by the Spin Fluctuations (구리 산화물 계열 초전도체에서의 스핀 요동에 의한 자체 에너지의 엘리아시버그 계산)

  • Hong, Seung-Hwan;Choi, Han-Yong
    • Progress in Superconductivity
    • /
    • v.13 no.3
    • /
    • pp.146-150
    • /
    • 2012
  • We solve the momentum resolved d-wave Eliashberg equation employing the magnetic excitation spectrum from the inelastic neutron scattering on the LSCO superconductors reported by Vignolle et al. The magnetic excitation spectrum exhibits 2 peaks: a sharp incommensurate peak at 18 meV at momentum (${\pi}$, ${\pi}{\pm}{\delta}$) and (${\pi}{\pm}{\delta}$, ${\pi}$) and another broad peak near 40~70 meV at momentum (${\pi}$, ${\pi}$). Above 70 meV, the magnetic excitation spectrum has a long tail that is shaped into a circle centered at (${\pi}$, ${\pi}$) with ${\delta}$. The sign of the real part of the self-energy is determined by the momentum position of the peaks of the magnetic excitation spectrum and bare dispersion. We will discuss the effects of the each component of the magnetic excitation spectrum on the self-energy, the pairing self-energy.

Fast Measurement using Wave-Cutoff Method

  • Seo, Sang-Hun;Na, Byeong-Geun;Yu, Gwang-Ho;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.30-30
    • /
    • 2011
  • The wave-cutoff tool is a new diagnostic method to measure electron density and electron temperature. Most of the plasma diagnostic tools have the disadvantage that their application to processing plasma where toxic and reactive gases are used gives rise to many problems such as contamination, perturbation, precision of measurement, and so on. We can minimize these problems by using the wave-cutoff method. Here, we will present the results obtained through the development of the wave-cutoff diagnostic method. The frequency spectrum characteristics of the wave-cutoff probe will be obtained experimentally and analyzed through the microwave field simulation by using the CST-MW studio simulator. The plasma parameters are measured with the wave-cutoff method in various discharge conditions and its results will be compared with the results of Langmuir probe. Another disadvantage is that other diagnostic methods spend a long time (~ a few seconds) to measure plasma parameters. In this presentation, a fast measurement method will be also introduced. The wave-cutoff probe system consists of two antennas and a network analyzer. The network analyzer provides the transmission spectrum and the reflection spectrum by frequency sweeping. The plasma parameters such as electron density and electron temperature are obtained through these spectra. The frequency sweeping time, the time resolution of the wave-cutoff method, is about 1 second. A short pulse with a broad band spectrum of a few GHz is used with an oscilloscope to acquire the spectra data in a short time. The data acquisition time can be reduced with this method. Here, the plasma parameter measurement methods, Langmuir probe, pulsed wave-cutoff method and frequency sweeping wave-cutoff method, are compared. The measurement results are well matched. The real time resolution is less than 1 ?sec. The pulsed wave-cutoff technique is found to be very useful in the transient plasmas such as pulsed plasma and tokamak edge plasma.

  • PDF

Evaluation of New LED Curing Light on Resin Composite Polymerization (발광 다이오드 광중합기의 복합레진 중합 평가)

  • Kang, Jieun;Jun, Saeromi;Kim, Jongbin;Kim, Jongsoo;Yoo, Seunghoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.2
    • /
    • pp.152-156
    • /
    • 2014
  • The purpose of this study is to compare efficiency of broad spectrum LEDs ($VALO^{(R)}$, Ultradent, USA) with conventional LED curing lights ($Elipar^{TM}$ Freelight 2, 3M ESPE, USA) using a microhardness test. The light curing units used were $VALO^{(R)}$ in three different modes and $Elipar^{TM}$ Freelight 2. The exposure time was used according to the manufacturer's instructions. After cured resin specimens were stored in physiological saline at $37^{\circ}C$ for 24 hours, microhardness was measured using Vickers microhardness tester. The microhardness of upper and lower sides of the specimens were analyzed separately by the ANOVA method (Analysis of Variance) with a significance level set at 5%. At upper side of resin specimens, an increased microhardness was observed in the broad spectrum LED curing light unit with a high power mode for 4 seconds and plasma emulation mode for 20 seconds (p < 0.05). However, at the lower side of resin specimens, there were no significant differences in microhardness between broad spectrum LED curing light unit and conventional LED curing light unit.

A Study on the Growth of ZnGa$_2$O$_4$ Thin Film Phosphors (ZnGa$_2$O$_4$ 박막형광체 성장에 관한 연구)

  • 정영호;김영진
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.2
    • /
    • pp.145-150
    • /
    • 1998
  • ZnGa2O4 thin film phosphors were deposited on Si(100) (111) wafers by rf magnetron sputtering. The ef-fects of substrates and deposition parameters on the growing mechanisms were studied. As a results of the effect of substrate temperature tranistions of growth orientation and different growing behaviors were ob-served. Also polycrystalline ZnGa2O4 thin film could not be achieved without oxygen gas. PL spectrum of ZnGa2O4 thin films were analyzed and showed broad band luminescence spectrum.

  • PDF

STRENGTH OF THE RAMAN SCATTERED HE II EMISSION LINES IN SYMBIOTIC STARS AND PLANETARY NEBULAE

  • LEE HEE-WON
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.55-60
    • /
    • 2003
  • In Lee, Kang & Byun (2001) the discovery of Raman scattered 6545 A feature was reported in symbiotic stars and the planetary nebula M2-9. The broad emission feature around 6545 A is formed as a result of Raman scattering of He II n = 6 $\to$ n = 2 photons by atomic hydrogen. In this paper, we introduce a method to compute the equivalent width of He II $\lambda$ 1025 line and present an optical spectrum of the symbiotic star RR Telescopii as an example for a detailed illustration. In this spectrum, we pay attention to the broad H$\alpha$ wings and the Raman scattered He II 6545 feature. The broad Ha wings are also proposed to be formed through Raman scattering of continuum around Ly$\beta$ by Lee (2000), and therefore we propose that the equivalent width of the He II $\lambda$ 1025 emission line is obtained by a simple comparison of the strengths of the 6545 feature and the broad H$\alpha$ wings. We prepare a template H$\alpha$ wing profile from continuum radiation around Ly$\beta$ with the neutral scattering region that is supposed to be responsible for the formation of Raman scattered He II 6545 feature. Isolation of the 6545 feature that is blended with [N II] $\lambda$ 6548 is made by using the fact that [N II] $\lambda$ 6584 is always 3 times stronger than [N II] $\lambda$ 6548. We also fit the 6545 feature by a Gaussian which has a width 6.4 times that of the He II $\lambda$ 6527 line. A direct comparison of these two features for RR Tel yields the equivalent width $EW_{Hel025} = 2.3{\AA}$ of He II $\lambda$ 1025 line. Even though this far UV emission line is not directly observable due to heavy interstellar extinction, nearby He II lines such as He II $\lambda$ 1085 line may be observed using far UV space instruments, which will verify this calculation and hence the origins of various features occurring in spectra around H$\alpha$.

Perceptual Space for Timbre using Auditory Spectrum (청각계 스펙트럼을 이용한 음색 지각공간)

  • Lee, Chai-Bong;Cha, Kyung-Hwan;Sone, Toshio
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.113-117
    • /
    • 1996
  • We study the similarities in timbre by varying both the form of the spectrum and the fundamental frequencies. A three dimensional configuration was drawn as a result of multidimensional scaling analysis. This configuration suggests that the difference in fundamental frequencies is one of the factors that change the timbre of complex tones. Also we considered the possibility of expressing the broad perception of timbre using auditory spectrum. The experimental result is well agreed with the calculation using the frequency weight matrix excluding the small value of auditory spectrum.

  • PDF

역삼투막 재료

  • 김창근
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.09a
    • /
    • pp.31-55
    • /
    • 1998
  • 1. Performance of RO membrane depends on chain structure (packing density) 2. Crosslinking of main chain is essential for the high performance RO membranes 3. Various bisphenols and polyaminostyrene can be promising materials for the fabrication of RO membranes. 4. By using of blend technique of reactant, we can expect broad spectrum of RO membrane and synergetic effects in membrane performance.

  • PDF

Isolation and Molecular Identification of Bacteriocin-producing Enterococci with Broad Antibacterial Activity from Traditional Dairy Products in Kerman Province of Iran

  • M, Khodaei;Sh, Soltani Nezhad
    • Food Science of Animal Resources
    • /
    • v.38 no.1
    • /
    • pp.172-179
    • /
    • 2018
  • One of the critical limitations to use of bacteriocins produced by lactic acid bacteria as a substitute for chemical antibiotics is the narrow spectrum of their antibacterial activity. The aim of present study was isolation and molecular identification of bacteriocin-producing enterococci with broad antibacterial spectrum. Bacteriocin-producing bacteria were isolated from native dairies in Kerman. Bacteriocins were purified by ammonium sulfate method and the effects of them were investigated on different strains of bacteria. Also, the effects of pH and heat on produced bacteriocins were investigated. High level bacteriocin-producing isolates were identified based on molecular tests. A total of 15 strains of bacteriocin-producing Enterococcus were isolated initially. Enterococcus faecium C-2 and Y-1 strains produced bacteriocins with the highest antibacterial effect. The bacteriocins were stable in pH ranges from 2 to 12 and their antibacterial activity was maintained after autoclave treatment. The maximum bactericidal effect was observed against Listeria monocytogenes and Pseudomonas aeruginosa. In conclusion, use of these bacteriocins as a substitute for chemical antibiotics is recommended.