• 제목/요약/키워드: Briquette factory

검색결과 3건 처리시간 0.016초

Influence of Environmental Exposures on Patients with Chronic Obstructive Pulmonary Disease in Korea

  • Hong, Yoonki;Lim, Myoung Nam;Kim, Woo Jin;Rhee, Chin Kook;Yoo, Kwang Ha;Lee, Ji-Hyun;Yoon, Ho Il;Kim, Tae-Hyung;Lee, Jin Hwa;Lim, Seong Yong;Lee, Sang Do;Oh, Yeon-Mok
    • Tuberculosis and Respiratory Diseases
    • /
    • 제76권5호
    • /
    • pp.226-232
    • /
    • 2014
  • Background: Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation and results from environmental factors and genetic factors. Although cigarette smoking is a major risk factor, other environmental exposures can influence COPD. The purpose of this study is to investigate the clinical characteristics of COPD according to the history of environmental exposure. Methods: The study population comprised of 347 subjects with COPD who were recruited from the pulmonary clinics of 14 hospitals within the Korean Obstructive Lung Disease Study Group. We classified environmental exposures according to history of living near factory, and direct exposure history to firewood or briquette. According to living environmental exposures, we compared the frequency of respiratory symptoms, pulmonary function, quality of life, exercise capacity, and computed tomography phenotypes. Results: Thirty-one subjects (8.9%) had history of living near factory, 271 (78.3%) had exposure history to briquette, and 184 (53.3%) had exposure history to firewood. Patients with history of living near a factory had a significantly longer duration of sputum, while patients with exposure to firewood tended to have lower forced expiratory volume in one second, and patients with exposure to briquette tended to have lower six minute walk distance. Conclusion: COPD subjects with the history of living near factory had more frequent respiratory symptoms such as sputum. Our data suggest that environmental exposure may influence clinical phenotype of COPD.

안심연료단지 주변지역 주민의 호흡기계질환에 대한 설문조사 및 건강검진 결과 분석 (A Study on the Results of Questionnaire Survey and Health Examination for Respiratory Disease among Residents in Briquette Fuel Complex in Ansim, Daegu)

  • 이관;임현술;김민기;민영선;이영현;김성우;최혜숙;안연순;사공준;유승도;김근배;윤미라
    • 한국산업보건학회지
    • /
    • 제25권3호
    • /
    • pp.355-365
    • /
    • 2015
  • Objectives: This study was conducted to better understand the relationship between health effects and exposure to dusts from a briquette fuel complex in Ansim, Daegu, Korea. Methods: The subjects of this study consisted of 2,980 persons over 40 years old who had lived 20 years or more around a briquette fuel complex in Daegu. We conducted a questionnaire survey, and chest radiography was performed. In addition, chest computed tomography(CT) (335 cases) and pulmonary function test(PFT) (658 cases) were done. Pneumoconiosis was diagnosed if one of three radiologists determined(or suspected) pneumoconiosis. We also conducted in-depth interviews for pneumoconiosis cases. We defined the exposed group as subjects residing within a 500 meter radius from the walls of the briquette fuel complex, and the others were defined as the control group. Results: Subjects in the exposed and control groups are respectively 715(24%) and 2,265 cases(76%). Major respiratory symptoms in the exposed group such as sputum, dyspnea, chest tightness and wheezing were significantly higher than in the control group. By chest radiography, 173 cases of pneumoconiosis or suspicious pneumoconiosis were detected. By PFT, 62 cases(29.5%) of chronic obstructive pulmonary disease(COPD) among 210 asymptomatic subjects were detected. Finally, by chest CT we concluded 28 cases to be pneumoconiosis, and eight cases among them proved to be pneumoconiosis by environmental exposure. Conclusions: Through this study, we concluded that health outcomes such as respiratory symptoms, pneumoconiosis, and COPD were caused by continuous exposure to dusts from the briquette fuel complex. Policies to reduce environmental exposure are needed, and cases of environmental disease should be intensively followed up by the government.

겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구 (Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter)

  • Ko, Jaesun
    • 한국재난정보학회 논문집
    • /
    • 제10권4호
    • /
    • pp.583-597
    • /
    • 2014
  • 난방기기에 의한 화재는 다양한 난방기기의 종류처럼 그 원인도 다양하고. 매년 계속되는 전통재래시장에서의 난방기기에 의한 화재사고가 빈번히 발생하여 인명 및 재산상의 손실을 초래하고 있다. 일반주택이나 아파트 등 대부분의 주거시설은 난방용 보일러가 보급되어 난방기기로 인한 화재가 그리 많지 않으나 식당, 시장의 점포와 사무실, 체육관, 공장, 작업장 등에서는 여전히 석유난로, 전기난로 등 난방기기를 사용 하고 있어 화재의 위험성에 노출되어 있다. 또한 난방용 기기의 발생건수를 살펴보면 가정용보일러, 목탄난로, 석유난로, 가스난로/스토브, 전기스토브/히터 순으로 발생한 것으로 분석되었으며, 인명피해 별 건수는 가스난로/스토브, 석유난로 /곤로, 전기히터/스토브, 연탄/석탄난로 순으로 분석되었다. 또한 가스 및 석유관련 난방용기기가 발생빈도(frequency)는 낮지만 화재강도(intensity)가 높은 것으로 분석 되었다. 따라서 본 연구의 목적은 다중이용시설인 전통재래시장에서 아직도 많이 사용되고 있고, 실제 화재발생사례가 많은 석유난로와 전기스토브에 의한 발화 위험성 즉 최소발화온도, 탄화 정도와 그에 따른 열유속을 정상상태와 비정상상태 하에서의 가연물의 접촉 및 전도로 인한 화재 발생 가능성을 재연하여 검토해 봄으로서 보다 과학적인 화재조사 및 감식 접근방법을 강구하고자 하였다. 재연실험 결과 실험체 2종(석유난로/전기스토브) 모두 양호한 축열 조건이 만들어지지 않는 한 발화위험성은 극히 적은 것으로 나타났지만 탄화의 상태는 각 부위별로 진행되는 것으로 분석되었다. 결국 화재로의 전이는 축열에 의한 발화이므로 최소한 화재장소의 축열 온도조건이 $500^{\circ}C$ 이상일 때 발화되는 것으로 분석되었다. 특히 전기스토브의 발열체인 석영관인 경우 가장 짧은 시간 내(10sec)에 $600^{\circ}C$ 이상의 온도로 급 가열 되어 이때의 열유속은 6.26kW/m2으로 나타나 이는 보온된 PVC케이블이 손상과 함께 인체에는 2도 화상을 입히는 결과를 나타내는 것으로 분석 되었다. 아울러 온도 조건 이외에 거리변화에 따른 열량의 감소분을 나타내는 형태계수(Geometric View Factor)와 화재하중(Fire Load)에 따른 온도 변화도 고려되어야 할 중요한 변수임 알았다. 따라서 이에 관한 세심한 화재조사 및 감식의 매뉴얼이 있어야 할 것으로 사료되며 이러한 실험에 의한 과학적이고 합리적인 노력들이 향후 화재조사 및 감식에 대한 매뉴얼 작성과 이론적 토대를 세우는데 기여하기를 기대한다.