• Title/Summary/Keyword: Bridge length

Search Result 682, Processing Time 0.021 seconds

Aesthetics of Samjae and Inequilateral Triangle Found in Ancient Triad of Buddha Carved on Rock - Centering on Formative Characteristics of Triad of Buddha Carved on Rock in Seosan - (고대(古代) 마애삼존불(磨崖三尊佛)에서 찾는 삼재(三才)와 부등변삼각(不等邊三角)의 미학(美學) - 서산마애삼존불의 형식미를 중심으로 -)

  • Rho, Jae-Hyun;Lee, Kyu-Wan;Jang, Il-Young;Goh, Yeo-Bin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.3
    • /
    • pp.72-84
    • /
    • 2010
  • This study was attempted in order to offer basic data for implementing and applying Samjonseokjo(三尊石造), which is one of traditional stone construction method, by confirming how the constructive principle is expressed such as proportional beauty, which is contained in the modeling of Triad of Buddha Carved on Rock that was formed in the period of the Three States, centering on Triad of Buddha Carved on Rock in Susan. The summarized findings are as follows. 1. As a result of analyzing size and proportion of totally 17 of Triad of Buddha Carved on Rock, the average total height in Bonjonbul(本尊佛) was 2.96m. Right Hyeopsi(右挾侍) was 2.19m. Left Hyeopsi(左挾侍) was 2.16m. The height ratio according to this was 100:75:75, thereby having shown the relationship of left-right symmetrical balance. The area ratio in left-right Hyeopsi was 13.4:13.7, thereby the two area having been evenly matched. 2. The Triad of Buddha Carved on Rock in Seosan is carved on Inam(印岩) rock after crossing over Sambulgyo bridge of the Yonghyeon valley. Left direction was measured with $S47^{\circ}E$ in an angle of direction. This is judged to target an image change and an aesthetic sense in a Buddhist statue according to direction of sunlight while blocking worshipers' dazzling. 3. As for iconic characteristics of Buddha Carved on Rock in Seosan, there is even Hyeopsi in Bangasang(半跏像) and Bongjiboju(捧持寶珠) type Bosangipsang. In the face of Samjon composition in left-right asymmetry, the unification is indicated while the same line and shape are repeated. Thus, the stably visual balance is being shown. 4. In case of Triad of Buddha Carved on Rock in Seosan, total height in Bonjonbul, left Hyeopsi, and right Hyeopsi was 2.80m, 1.66m, and 1.70m, respectively. Height ratio in left-right Hyeopsibul was 0.60:0.62, thereby having been almost equal. On the other hand, the area ratio was 28.8:25.2, thereby having shown bigger difference. The area ratio on a plane was grasped to come closer to Samjae aesthetic proportion. 5. The axial angle of centering on Gwangbae was 84:46:50, thereby having been close to right angle. On the other hand, the axial angle ratio of centering on Yeonhwajwa(蓮華坐: lotus position) was measured to be 135:25:20, thereby having shown the form of inequilateral triangle close to obtuse angle. Accordingly, the upper part and the lower part of Triad of Buddha Carved on Rock in Susan are taking the stably proportional sense in the middle of maintaining the corresponding relationship through angular proportion of inequilateral triangle in right angle and obtuse angle. 6. The distance ratio in the upper half was 0.51:0.36:0.38. On the other hand, the distance ratio in the lower half was 0.53 : 0.33 : 0.27. Thus, the up-down and left-right symmetrical balance is being formed while showing the image closer to inequilateral triangle. 7. As a result of examining relationship of Samjae-mi(三才美) targeting Triad of Buddha Carved on Rock in Susan, the angular ratio was shown to be more notable that forms the area ratio or triangular form rather than length ratio. The inequilateral triangle, which is formed centering on Gwangbae(光背) in the upper part and Yeonhwajwa(lotus position) in the lower part, is becoming very importantly internal motive of doubling the constructive beauty among Samjae, no less than the mutually height and area ratio in Samjonbul.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.