• Title/Summary/Keyword: Bridge Deck

검색결과 930건 처리시간 0.027초

A Study on Approximate Analysis of Steel Deck Bridges with Guss Asphalt Using Influence Line (영향선을 이용한 강상판 교량의 구스 아스팔트 포장에 대한 근사해석 연구)

  • Seo, Ki-Hong;Ka, Hoon;Kong, Min-Sik;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • 제10권4호
    • /
    • pp.127-135
    • /
    • 2006
  • In this study, steel deck bridges are chosen as analytic model to show the structural behaviors generated by high temperature of pavement and to formulate the simplified approximate analysis of thermal effects. In general, the thermal effect is changed by the material property of pavements and environmental temperature as well as shape, size and boundary conditions of bridge. Specially, this effect is the representative initial stress problem dependent on time. The thermal effect, however, does not depend on time and thermal effect is regarded as initial load in this study. After these thermal loading is modelled as moving loads, influence lines of reactions of shoes are calculated and the successive pavement steps with arbitrary segments are determined to minimize the thermal effect of shoes by influence line.

Seismic Response Control of Cable-Stayed Bridge using Fuzzy Supervisory Control Technique (퍼지관리제어기법을 이용한 사장교의 지진응답제어)

  • Park, Kwan-Soon;Koh, Hyun-Moo;Ok, Seung-Yong;Seo, Chung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • 제8권4호
    • /
    • pp.51-62
    • /
    • 2004
  • Fuzzy supervisory control technique for the seismic response control of cable-stayed bridges subject to earthquakes is studied. The proposed technique is a hybrid control method, which adopts a hierarchical structure consisting of several sub-controllers and a fuzzy supervisor. Sub-controllers are independently designed to reduced the responses to be controlled of a cable-stayed bridge, and a fuzzy supervisor achieves improved seismic control performance by tuning the pre-designed sub-controllers. It is realized by converting static gains of the sub-controllers into time-varying dynamic gains through the fuzzy inference mechanism. To evaluate the feasibility of the proposed technique, the benchmark control problem of cable-stayed bridge proposed by Dyke et al. is adopted. The control variables for the seismic response control of the cable-stayed bridge are determined to be t도 shear forces and bending moments at the base of the towers, the longitudinal displacements at the top of the towers, the relative displacements between the deck and the tower, and the tensions in the stay cables. Comparative results between the fuzzy supervisory controller and LQG controller demonstrate the effectiveness of the proposed control technique.

Response Analysis of RC Bridge Pier with Various Superstructure Mass under Near-Fault Ground Motion (근단층지반운동에 대한 상부구조 질량 변화에 따른 RC 교각의 응답분석)

  • Park, Chang-Kyu;Chung, Young-Soo;Lee, Dae-Hyung
    • Journal of the Korea Concrete Institute
    • /
    • 제22권5호
    • /
    • pp.667-673
    • /
    • 2010
  • The near fault ground motion (NFGM) is characterized by a single long period velocity pulse with large magnitude. NFGMs have been observed in recent strong earthquakes, Northridge (1994), Japan Kobe (1995), Turkey Izmit (1999), China Sichuan (2008), Haiti (2010) etc. These strong earthquakes have caused considerable damage to infrastructures because the epicenter was close to the urban area, called as NFGM. Extensive research for the far field ground motion (FFGM) have been carried out in strong seismic region, but limited research have been done for NFGM in low or moderate seismic regions because of very few records. The purpose of this research is to investigate and analyze the seismic response of reinforced concrete bridge piers subjected to near-fault ground motions. The seismic performance of six RC bridge piers depending on three confinement steel ratios and three superstructure mass was investigated on the shaking table. From these experimental results, it was confirmed that the reduction of seismic performance was observed for test specimens with lower confinement steel ratio or more deck weight. The displacement ductility of RC bridge piers in terms of the stiffness degradation is proposed based on test results the shaking table.

Evaluation of Behavior of Direct Fixation Track and Track Girder Ends on Yeongjong Grand Bridge (영종대교 강직결 궤도 및 종형거더 단부의 거동 분석)

  • Choi, Jung-Youl;Chung, Jee-Seung;Kim, Jun-Hyung;Lee, Kyu-Yong;Lee, Sun-Gil
    • Journal of the Korean Society of Safety
    • /
    • 제31권6호
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study is to investigate the influence of train-induced end rotation of simple supported track girder on the performance of a direct fixation track system (DFTS) in Yeongjong grand bridge. In this study, the influences of deflection of a DFTS and track girder on dynamic rail-track girder interaction forces for the track girder ends currently employed in airport express lines were assessed by performing field tests using actual vehicles running along the service lines. Therefore, the dynamic displacement of rail and track girder and the fastener stress on the center and ends sections of DFTS were measured for two different trains (AREX and KTX) running in Yeongjong grand bridge. A three-dimensional finite element analysis (FEA) model using the time-history function based on the design wheel load was used to predict the train-induced track and track girder displacement, and the FEA and field test results were compared. The analytical results reproduced the experimental results well within about 3-7% difference in the values. Therefore, the FEA model of DFTS on track girder is considered to provide sufficiently reliable FEA results in the investigation of the behavior of DFTS. Using the analytical and experimental results, the influence of train-induced end rotation of simple supported track girder on the interaction behavior of rail and track girder installed on a simple supported track girder ends, i.e., upward displacement of rail-track girder and the fastener stress, was investigated. It was found that the train-induced end rotation effect of track girder was not significantly affected by the upward displacement of rails and the fastener stresses of track girder ends. Further, the interaction behavior of rail and track girder were similar to or less than that of the general railway bridge deck ends, nevertheless the vertical displacement of track was higher than that of conventional DFTS on the general railway bridge. From the results, the dynamic responses of the DFTS on track girder ends were not significantly affected by the safety and stability of DFTS ends.

Cable vibration control with internal and external dampers: Theoretical analysis and field test validation

  • Di, Fangdian;Sun, Limin;Chen, Lin
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.575-589
    • /
    • 2020
  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.

A Study on Container Monitoring Loaded into the Hold in Maritime Logistics (해상운송 환경에서 IP-RFID 기술을 이용한 선박 홀드에 적재된 컨테이너 상태 모니터링에 관한 연구)

  • Kim, Tae-Hoon;Choi, Sung-Pill;Moon, Young-Sik;Lee, Byung-Ha;Jung, Jun-Woo;Park, Byung-Kwon;Kim, Jae-Joong;Choi, Hyung-Rim
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제41권11호
    • /
    • pp.1446-1455
    • /
    • 2016
  • The recent increase of fresh farm products, hazardous cargos, and high-priced goods in marine transportation has caused an increased demand of cargo owners and shipping companies with regard to the monitoring of the location and state of cargo. To meet this increase, numerous technologies are being studied for the monitoring of the cargo state. Cargo containers on a ship are loaded on a ship's deck and in a ship's hold, which is located under the deck. However, Since the developed technologies mostly transfer the container status information that collected by mobile communication, it costs a lot to install communication infrastructure on ship. And the ship's hold is completely sealed with a cover, and communication with the reader positioned at the ship's bridge is difficult. Therefore, most existing studies on container monitoring on ships have focused on the monitoring of containers loaded on a ship's deck. Accordingly, this study suggested system configuration for the monitoring of containers in a ship's hold using IP-RFID technology. The suggested system configuration was tested on an actual ship under navigation, and the test results are given in this study. The test results verified that the monitoring of containers in a ship's hold using IP-RFID technology is effective.

Effects of Lateral Bracing on the Load Distribution and Torsional Behaviors in Continuous Two-Girder Bridges (연속 2-거더교에서 수평브레이싱이 하중 분배 및 비틂 거동에 미치는 영향)

  • Hwang, Min Oh;Yoon, Tae Yang;Park, Yong Myung;Joe, Woom Do Ji;Hwang, Soon Young
    • Journal of Korean Society of Steel Construction
    • /
    • 제19권6호
    • /
    • pp.671-680
    • /
    • 2007
  • In this study, we performed a loading test to evaluate the effect of load distribution on continuous two-span plate-girder bridges with or without bottom lateral bracing using one-fifth-scale bridge specimens. From the test results, when specimens with lateral bracing were loaded eccentrically, the load distribution capacity of the concrete deck and cross beam improved and greater loading was distributed to the other side of the girder subjected to loading. The load distribution rate of the specimens with and without lateral bracing system was evaluated from the analytical model that was verified by the test results. From the result of the quantitative evaluation, when specimen without lateral bracing was loaded eccentrically, mostly 21% of loading according to the concrete deck was distributed to the other side of the girder subjected to loading. However, when specimen with lateral bracing was loaded eccentrically, the load distribution rate increased by 1.7 times as all cross beams, bracing and concrete deck participated in load distribution. The reason is that the torsional rigidity increased as the model with lateral bracing behaved like a pseudo-closed box section.

Experimental Study of Low-Frictional Behavior for Sliding Slab Track (슬라이딩 궤도의 저마찰 거동에 대한 실험적 연구)

  • Kim, Tae-Gu;Jung, Dong-Ki;Lee, Kyoung-Chan
    • Journal of the Korean Society for Railway
    • /
    • 제20권2호
    • /
    • pp.241-247
    • /
    • 2017
  • Railway bridges with continuously welded rail have a limitation of span length due to track-bridge interaction. In order to overcome this, a sliding slab track system has been developed that comprises with a low-frictional sliding layer between the bridge deck and the track slab to isolate the longitudinal behavior between the bridge and the track. In this study, a real scale track system is prepared to experimentally evaluate the longitudinal frictional behavior. Applied loading rates were 0.2, 1.0, 5.0 and 10mm/min; vertical mass on the track are track slab only, 5,000 and 10,000kg added mass, respectively. Test results showed that the resulting frictional coefficients varied from 0.22 to 0.33. In addition, 10,000 cycle loadings were applied to simulate repetitive sliding to represent 30 years of service life. The frictional coefficient increase was measured and found to be 7% of that of the initial loading stage, which means that the sliding layer is adequate to provide low-frictional behavior for the sliding slab track system. Effects of changes of the frictional coefficient of the sliding layer were analyzed by rail-structure interaction analysis.

A Study on the Optimum Cross-section and Tendon Profiles of 60 m span Half-Decked PSC Girder Bridge (Half-Deck을 포함한 60 m 경간 PSC 거더의 단면 및 텐던 프로파일 최적화 연구)

  • Kim, Tae Min;Kim, Do-Hak;Kim, Moon Kyum;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제31권6A호
    • /
    • pp.417-424
    • /
    • 2011
  • This study focused on development of 60 m span PSC girder considering not only structural performance, but also economical efficiency and constructability including from the improvement of cross-section to the tendon profiles in sequence. Bulb-T type cross section was derived from optimization and actual possibilities to design a bridge were assessed through cross section evaluation. Tendons were also arranged efficiently so that the girder could resist the service load effectively. After developed girder was applied to a sample bridge, result of finite element analysis proved all load steps were satisfied with the allowable stress. Furthermore, it seemed that sufficient redundancy will be available to design a bridge safely. Based on these, a full-scale 60 m span girder was fabricated and 4 point bending test was performed. An initial crack occurred over twice of the service load in this experiment, which establishes adequate structural performance. 60 m span Half-Decked PSC girder developed in this study has a lower height for the given span which resulted from cross section improvement and efficient tendon layout. This girder also has not only the structural advantage, but also advantages in economical efficiency and constructability.

Review on Applicability of Local Scour Depth Calculation Formula in River (하천 세굴심 산정을 위한 교각 세굴심 산정식의 적용성 검토)

  • Min, ByungYun;Chang, HyungJoon;Lee, HoJin;Kim, SungDuk
    • Journal of Korean Society of Disaster and Security
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2019
  • The basic analysis of Soil and structural mechanics for the bridge substructure affected by the flow of water is sufficient in the construction of such bridges, but the stability of scour resulting from hydraulic phenomena is insufficient. In addition, it is not enough to estimate the scour depth of the bridge which reflects the watershed characteristics of the domestic river because it uses the formula for calculating the scour depth of the overseas piers in calculating the scour depth of the bridge. In this study, the application of the CSU (1993) formula, which is currently applied to the national river design criteria, was reviewed between the two formulas after calculating the scour after calculating the scour by applying another bridge deck scour calculation formula to take into account the uncertainty in the calculation of scour. In this study, in addition to the CSU (1993) formula, which is currently applied to Korean river design criteria, another scour depth calculation formula is applied to calculate uncertainty in scour depth calculation, was reviewed between the two formulas. The review confirmed that the SSE (%) showed a difference of at least 2.08%, up to 91.23%, and SSEn(%) at least 0.19%, up to 415.91%, when compared to the measured depth of the pier based on the hydraulic model experiment and the depth of the pier calculated with the nine scour depth formulas in use. In other words, it is confirmed that there are many differences between the scouring formulas of piers. The results of this study are expected to be used to estimate scour depth in future river design.