• Title/Summary/Keyword: Breathing protocol

Search Result 22, Processing Time 0.028 seconds

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF

Inspiratory Muscle Strengthening Training Method to Improve Respiratory Function : Comparison of the Effects of Diaphragmatic Breathing with Upper Arm Exercise and Power-Breathe Breathing (호흡 기능 향상을 위한 들숨근 강화 훈련 방법 : 위팔운동을 동반한 가로막 호흡과 파워브리드 호흡의 효과 비교)

  • Lee, Keon-Cheol;Choo, Yeon-Ki
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.3
    • /
    • pp.203-211
    • /
    • 2021
  • Purpose : It was to compare changes in respiratory function (pulmonary function, inspiratory function) after four weeks of inspiratory muscle strengthening training (diaphragmatic breathing with upper arm exercise, Power-Breathe breathing) for 36 healthy people. Methods : Subjects were randomly assigned to diaphragmatic breathing with upper arm exercise (Group I) and Power-breathe breathing (Group II) was conducted by the protocol for four weeks five times per week. As the main measurement method for comparison between groups For pulmonary function, Forced Vital Capacity (FVC) and Forced Expiratory Volume at One second (FEV1) were used, and for inspiratory function, Maximum Inspiratory Capacity (MIC), Maximum Inspiratory Pressure (MIP), and Maximum Inspiratory Flow Rate (MIFR) were used. Results : In changes in pulmonary function between groups, FVC and FEV1 showed no significant difference, and in inspiratory function changes, MIC showed no significant difference, but in MIP and MIFR, Group B significantly improved over Group A. Conclusion : The progressive resistance training using the Power-breath device applied to the inspiratory muscle did not show a significant difference in the increase in the amount of air in the lungs and chest cage compared to the diaphragmatic breathing training accompanied by the upper arm exercise. However, by increasing the air inflow rate and pressure, it showed a more excellent effect on improving respiratory function.

The Effect of Breathing Training Program and Swiss-ball Exercise on Respiratory Circulation Function and Tidal Volume (호흡운동 프로그램과 스위스 볼 운동이 호흡순환기능과 일회 환기량에 미치는 영향)

  • Kim, Byung-Kon;Lee, Myoung-Hee
    • PNF and Movement
    • /
    • v.12 no.3
    • /
    • pp.181-188
    • /
    • 2014
  • Purpose: The purpose of this current study is to compare the effectiveness of respiratory circulation function and tidal volume according to two different types of practice methods, in terms of breathing training program and abdominis muscle strengthening using a swiss ball. Methods: The subjects were consist 18 college students, were randomly and evenly assigned to either breathing training program group (BTG) or swiss-ball exercise group (SEG). Exercise program was applied for 60 minutes, 3 times a week, for 6 weeks. Before, after 3 weeks and after 6 weeks of exercises, the subjects were tested using the bruce protocol. The significance of differences between the BTG and the SEG was evaluated by analysis of two-way repeated measures ANOVA. Results: There was an increase in respiratory circulation function after both of exercise. Especially, there was significant difference between the before and after 6 weeks in the BTG. Also, change of respiratory circulation function in BTG was significantly greater than SEG. Tidal volume was no significant differences between the before and after 6 weeks in both groups. In addition, there was significant difference between BTG and SEG. Conclusion: These results suggest that direct breathing training program were more useful to improve of respiratory circulation function.

Zigbee Based Wireless Respiration Monitor System (지그비 통신 기반의 근거리 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.142-147
    • /
    • 2008
  • Abdominal circumference changes due to breathing by the respiratory muscle activity such as diaphragm, which would partially represent the lung volume variation. The present study introduced conductive rubber molded in a cord shape incorporated with a patient's pants. The conductive rubber cord operated as a displacement transducer to measure the lung or abdominal volume changes. Signal extraction circuitry was developed to obtain the volume and its derivative(or the flow) signals followed by wireless transmission based on the Zigbee communication protocol in a size of $65mm{\times}105mm$ easily put in pocket. Breathing frequency was accurately evaluated and breath pattern analysis seemed feasible, since respiratory behaviours such as maximal inspiration and cough were well identified. Remote wireless receiver module also enabled to monitor both volume and flow signals during resting breathing on a PC terminal.

Comparison of the Effect of Inhalation and Exhalation Breathing Exercises on Pulmonary Function of Patients With Cervical Cord Injury (경수손상환자들의 폐기능 향상을 위한 흡기 및 호기 호흡운동 방법의 효과 비교)

  • Jean, Yong-Jin;Oh, Duck-Won;Kim, Kyung-Mo;Lee, Young-Jung
    • Physical Therapy Korea
    • /
    • v.17 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This study aimed to compare 2 protocols recommended to patients with chronic cervical cord injury: each protocol included breathing exercises (inhalation-oriented or exhalation-oriented) and facilitation maneuver for the accessory respiratory muscles. Seventeen patients with chronic cervical cord injury volunteered to participate in this study, and we randomized these patients into 2 groups: the inhalation-oriented breathing exercise group (IOBEG) and exhalation-oriented breathing exercise group (EOBEG), consisting of 8 and 9 patients, respectively. Patients in the IOBEG performed inspiratory exercises using intermittent positive pressure breathing devices, while those in the EOBEG performed expiratory exercises using incentive spirometry. All exercises were performed by the subjects twice a day for 4 weeks, with each session lasting an average of 20 min. The outcomes were assessed on the basis of the pre- and post-treatment values of vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), and FEV1/FVC. In the IOBEG, no significant differences were observed between the pre- and post-treatment values of any of the measured variables (p>.05); however, in the EOBEG, significant improvement was noted in the VC, FVC, FEV1 measured (p<.05) after the treatment. In addition, the rates of change in the values of VC, FVC, and FEV1 differed significantly between the 2 groups (p<.05). These findings suggest that the EOBEs can enhance respiratory function and are clinically feasible in patients with chronic cervical cord injury. Further studies will be undertaken to evaluate the clinical application of these findings.

Effect of Different Air Hole Diameters of the Inspiratory Muscle Trainer on the Rating of Perceived Exertion and Inspiratory Muscle Activity during Breathing Exercise

  • Shin, Areum;Kim, Kisong
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.7 no.2
    • /
    • pp.133-139
    • /
    • 2019
  • Purpose : This study aims to investigate the rating of perceived exertion (RPE) and muscle activity of the inspiratory primary and accessory muscle during breathing exercise with different air hole diameters of the inspiratory muscle trainer (IMT). Methods : The Borg's scale and surface electromyography (EMG) was used to collect data of the RPE and muscle activity of the inspiratory primary the external intercostal (EI) and diaphragm (DIA) and accessory muscles anterior scalene (AS), sternocleidomastoid (SCM), pectoralis major (PM), and upper trapezius (UT) muscles during breathing exercise with different air hole diameters (6 mm, 4 mm, and 2 mm) of the IMT in healthy young male subjects. Results : The RPE and muscle activities of the AS, SCM, and UT are increased significantly in accordance to the decreasing diameter of air hole of air tip in IMT. However, there are no differences in the muscle activities of the PM, EI, and DIA based on differences of diameters of air hole of air tip in IMT. Conclusion : The smaller the diametr of IMT air-hole, RPE and muscle activities of AS, SCM and UT were increased. Therefore, further study would be necessary to investigate the proper intensity and relaxation posture for the exercise protocol to strengthen the inspiratory primary muscles.

Use of real-time ultrasound imaging for biofeedback of diaphragm motion during normal breathing in healthy subjects

  • Cho, Ji-Eun;Hwang, Dal-Yeon;Hahn, Joohee;Lee, Wan-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.7 no.3
    • /
    • pp.95-101
    • /
    • 2018
  • Objective: To determine if the provision of visual biofeedback using real-time rehabilitative ultrasound imaging (RUSI) enhances the acquisition and retention of diaphragm muscle recruitment during exercise. Design: Two group pretest posttest design. Methods: Thirty healthy subjects were randomly assigned to the verbal feedback group (VG, n=15) or the visual and verbal feedback group (VVG, n=15). The VG performed breathing exercises 10 times with verbal feedback, and the VVG also performed breathing exercises 10 times with verbal feedback and visual feedback with the use of RUSI to measure changes in diaphragm thickness (DT). For DT, the mid-axillary lines between ribs 8 and 9 on both sides were measured in standing, and then the chest wall was perpendicularly illuminated using a linear transducer with the patients in supine to observe the region between rib 8 and 9 and to obtain 2-dimensional images. DT was measured as the distance between the two parallel lines that appeared bright in the middle of the pleura and the peritoneum. After one week, three repetitions (follow-up session) were performed to confirm retention effects. Intra- and between- group percent changes in diaphragm muscle thickness were assessed. Results: In the VVG, the intervention value had a medium effect size compared to the baseline value, but the follow-up value decreased to a small effect size. In the between-group comparisons, during the intervention session, the VVG showed no significant effect on percent change of DT but had a medium effect size compared to the VG (p=0.050, Cohen's d=0.764). During the follow-up session, retention effect did not persist (p=0.311, Cohen's d=0.381). Conclusions: RUSI can be used to provide visual biofeedback and improve performance and retention in the ability to activate the diaphragm muscle in healthy subjects. Future research needs to establish a protocol for respiratory intervention to maintain the effect of diaphragmatic breathing training using RUSI with visual feedback.

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF