• Title/Summary/Keyword: Breathing phase

Search Result 53, Processing Time 0.024 seconds

Analysis of Prehospital Care Report for Improving Emergency Service at Prehospital Phase (병원 전 단계 응급의료서비스 개선을 위한 구급활동일지)

  • Choi, Gil-Soon;Kim, Youn-Kyoung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.3
    • /
    • pp.163-174
    • /
    • 2007
  • Purpose : This study analyzes prehospital care report of emergency service at prehospital stage, examines characteristics of activities of 119 paramedics and its users and aims to provide help for improving emergency system in future. Methods : Data collected were 119 prehospital care report and hospital records with 7,160 patients to emergency room by 119 ambulance from Jan. 1 to Dec. 31, 2006 and percentage and frequency of the data were obtained. Results : 1) Use of emergency room by 119 ambulance was increased in summer and autumn such as August(9.1%), September(11.2%) and October(13.5%) and it was more frequently used on Monday(17.3%), Saturday(17.2%) and Friday(16.1%) by telephone(98.6%). 2) Using emergency room was most in over sixties(51.8%), men(64.2%), community residents (78.3%), by report of family(50.3%) and at '09:01~12:00'(16.5%). 3) Symptoms of emergency room users included headache, chest pain, stomachache, lumbago and others as 40.6% and places where patients were found were at home(60.1%) due to chronic internal diseases at 49.2%. 4) Most of non-emergency patients(80.2%) arriving at hospital had normal pupil condition (88.4%) and clear consciousness(71.2%) and most of them left hospital after having first-aid treatment. 5) Physiological symptom tests evaluated by paramedics at prehospital stage included blood pressure(56.6%), pulse(22.9%), breathing(13.0%) and temperature(9.2%), and there was no SPo2 case. 6) Classification of severity by paramedics showed difference as emergency patients(18.0%) by paramedics and those(24.9%) by hospital. 7) First-aid treatments by paramedics at prehospital stage were promoting comfort(28.9%), hemostasis(7.7%), fixing cervical vertebrae(4.0%) and ensuring vein route(3.1%). 8) Selectors of medical agency were patients or guardians(86.2%) and emergency medical technicians(73.6%). Conclusion : To sum up the above research, it was found that percentage of using 119 ambulance by non-emergency patients was higher and paramedics performed basic first-aid treatment rather than professional first-aid treatment due to several conditions such as legal problems, range of allowance, etc. Therefore, it is considered that method to reduce frequency of ambulance by non-emergency patients and approaches to alleviate limitations of allowance of paramdeics to make them perform effective first-aid treatment at prehospital stage should be sought in the dimension of individual, organization and government.

  • PDF

Comparison on postural control between abdominal draw-in maneuver and abdominal expansion maneuver in persons with stroke

  • Choi, Ho-Suk;Shim, Yu-Jin;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.3
    • /
    • pp.113-119
    • /
    • 2016
  • Objective: The effect of abdominal expansion maneuver (AEM) and abdominal draw-in maneuver (ADIM) on postural control in an unsupported position in stroke patients. Design: Randomized controlled trial. Methods: A total of 36 persons with hemiplegic stroke participated in this study. The subjects were randomly divided into an AEM experimental group (n=12), an experimental ADIM group (n=12), and a control group (n=12). We collected the general characteristics of all subjects and the pre-test results before the intervention and after 4 weeks of the intervention. The trunk stabilization training of the ADIM and AEM group were performed 15 minutes a day, 3 times a week for 4 weeks, and general physical therapy was performed 2 times a day, 30 minutes per session, 5 times a week for all three groups. The control group received joint mobilizations, muscle strengthening, endurance strengthening, and gait exercises along with treatment of the central nervous system, such as neuro-developmental treatment, mat, and gait training. The AEM is an inspiratory phase of tidal breathing expanding the lateral lower ribcage in a lateral direction with minimal superior movements of the chest. Then the lower abdomen expands and the navel moves in an anterior-caudal direction. The ADIM is a repeated contraction and relaxation of the anal sphincter during inspiration. The navel pulls the lower abdomen to the direction of the spine without the movement of the trunk and pelvis. Results: Before and after the interventions, medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area 95% was a statistically significant change in all three groups (p<0.05). The post-hoc test showed a significant improvement in medial-lateral axis movement distance, anterior-posterior axis movement distance, sway mean velocity, and sway area in the AEM group compared with the control group, and in the ADIM group compared with the control group (p<0.05). Conclusions: In conclusion, both AEM training and ADIM training are necessary interventions to maintain the independent sitting position according to the characteristics of the patient.

Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator (방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구)

  • Seo, Jeong-Min;Kim, Chan-Hyeong;Park, Byoung-Suk;Park, Cheol-Soo;Jang, Hyon-Chol;Kim, Joung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6932-6939
    • /
    • 2015
  • The respiration is one of important factor in the radiation therapy. The existing commercial method of cone-beam computed tomography on LINAC does not consider respiratory motion of patient hence the images are both distorted and inaccurate. In this study, the cone-beam computed tomography images have been reconstructed from back projection radiography of specific phase on breathing cycle which concerned about respiratory movement in radiation therapy. This study investigated how different between cone-beam CT images with and without gating respiratory movement, and this paper provides that guide and implementation of gated cone-beam CT on radiation therapeutic equipment.

Emergency Medical Participants' recognition of The Emergency Medical Technicians' Job Awareness (응급실 내 의사와 간호사가 인식하는 병원 내 응급구조사의 업무인식도)

  • Bae, Ki-Sook;Han, Song-Yi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2908-2914
    • /
    • 2013
  • This study investigated hospital EMT' scope of work perceived by emergency medical service providers by surveying 122 emergency medical service providers working at university hospitals in Daejeon and Chung-nam in order to provide basic materials for improving EMT' roles and legal regulations related to their works and enhancing the quality of emergency medical services. According to the results of this study was $3.23{\pm}0.67$ for the 40 items surveyed, which was somewhat higher than average. By area, job awareness was highest for trauma care, which was followed by hospital phase and breathing assistance, and lowest for medication. In order for emergency medical service providers to recognize hospital EMT' works, first of all, EMT need to carry out their jobs and roles faithfully. Therefore, educational institutions should provide substantial education programs. What is more, legally clear definitions should be made on the job of EMT, and campaigns and monitoring should be made continuously for EMT.

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

Development and Application of Radiological Risk Assessment Program RADCONS (방사능위해성평가 프로그램 RADCONS의 개발 및 적용)

  • Jeong, Hyojoon;Park, Misun;Hwang, Wontae;Kim, Eunhan;Han, Moonhee
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.89-97
    • /
    • 2013
  • RADCONS Ver. 1.0 (RADiological CONSequence Assessment Program) was developed for radiological risk assessment in this study. A Gaussian plume model was used to analyze the fate and transport of radionuclides released into the air in case of accidents. Both single meterological data and time series meterological data can be used in RADCONS. To assess the radiological risk of the early phase after an accident, ED (Effective Dose) estimated by both deterministic and probabilistic approaches are presented. These EDs by deterministic and probabilistic will be helpful to efficient decision making for decision makers. External doses from deposited materials by time are presented for quantifying the effects of mid and late phases of an accident. A radiological risk assessment was conducted using RADCONS for an accident scenario of 1 Ci of Cs-137. The maximum of ED for radii of 1,000 meters from the accident point was 8.51E-4 mSv. After Monte-Carlo simulation, considering the uncertainty of the breathing rate and dispersion parameters, the average ED was 8.49E-4, and the 95 percentile was 1.10E-3. A data base of the dose coefficients and a sampling module of the meteorological data will be modified to improve the user's convenience in the next version.

Analysis of Intrafractional Mass Variabilities Using Deformable Image Registration Program (영상변조 프로그램을 이용한 호흡 위상 간 종양의 움직임 특성 분석)

  • Cho, Jeong-Hee;Kim, Joo-Hoo;Seo, Sun-Youl;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.173-181
    • /
    • 2012
  • The aim of this study is to compare the geometric characteristics of the lung tumor, such as tumor centroid, HU change relative to breath phase, depending on tumor location and adhesion using 4DCT and deformable image registration program (MIMVista). The Y axis change was most significant and the mean Y axis centroid fluctuation was $7.32{\pm}6.88mm$ in lower lung tumor. The mean HU variation in lower lung mass has changed more than other locations, and its mean HU variation was $7.7{\pm}4.97%$ and non-adhered mass was more changed. Correlation for the mass volume between 3DCT and MIP was very high and its coefficient was 0.998. The effect of tumor location, adhesion and diaphragm excursion to geometric uncertainties was analyzed by linear regression model, it was influenced to mass deformation and geometrical variation so much except diaphragm excursion. but intra-fractional and inter-patient's uncertainties were great, so it couldn't find any exact deformation trend.

Design of FMCW Radar Signal Processor for Human and Objects Classification Based on Respiration Measurement (호흡 기반 사람과 사물 구분 가능한 FMCW 레이다 신호처리 프로세서의 설계)

  • Lee, Yungu;Yun, Hyeongseok;Kim, Suyeon;Heo, Seongwook;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.4
    • /
    • pp.305-312
    • /
    • 2021
  • Even though various types of sensors are being used for security applications, radar sensors are being suggested as an alternative due to the privacy issues. Among those radar sensors, PD radar has high-complexity receiver, but, FMCW radar requires fewer resources. However, FMCW has disadvantage from the use of 2D-FFT which increases the complexity, and it is difficult to distinguish people from objects those are stationary. In this paper, we present the design and the implementation results of the radar signal processor (RSP) that can distinguish between people and object by respiration measurement using phase estimation without 2D-FFT. The proposed RSP is designed with Verilog-HDL and is implemented on FPGA device. It was confirmed that the proposed RSP includes 6,425 LUT, 4,243 register, and 12,288 memory bits with 92.1% accuracy for target's breathing status.

Evaluation of the Accuracy and usability of Trigger mode in Respiratory Gated Radiation Therapy (호흡동조방사선치료를 위한 Trigger mode 투시영상 획득 시 호흡 속도에 따른 정확성 평가 - Phantom Study)

  • Park, je wan;Kim, min su;Um, ki cheon;Choi, seong hoon;Song, heung kwon;Yoon, in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.25-33
    • /
    • 2021
  • Purpose : The purpose of this study is to evaluate the accuracy and usefulness of the Trigger mode for the Respiratory Gated Radiation Therapy (RGRT) Materials and methods : A QUASAR respiratory phantom that inserted a 3 mm fiducial marker (a gold marker) was used to estimate the accuracy of the Trigger mode. And the 20 bpm was used as reference respiration rate in this study. The marker that placed at the center of the phantom was contoured, and the lower threshold of a gating window was fixed at 2.0 mm using an OBI with Truebeam STxTM. The upper threshold was measured every 0.5 mm from 1.0 mm to 3.0 mm. The respiration rates were changed every 10 bpm from 10 bpm to 60 bpm. We repeatedly measured five times to check the error rate of the trigger mode in the same condition. Result : The differences of a distance from a peak phase to upper threshold, 1.0 to 3.0 mm at a 20 bpm as a reference for 3 days in a row were 0.68±0.05 mm, 0.91±0.03 mm, 1.23±0.03 mm, 1.42±0.04 mm, and 1.66±0.06 mm, respectively. Measurement result of changes in respiratory rate compared to baseline respiratory rate in maximum absolute difference. The coefficient of determination (R2) to estimate the correlation between the respiration velocity and variation of absolute difference was on average 0.838, 0.887, 0.770, 0.850, and 0.906. The p-values of all the variables were below 0.05. Conclusion : Using Trigger mode during respiratory gated radiation therapy (RGRT), accuracy and usefulness of trigger mode at reference breathing rate were confirmed. However, inaccuracies depending on the rate of breathing it could be uncertain in case of respiration rate is faster than 20 bpm as a standard respiration rate compared to slower than 20 bpm. Consequently, when conducting a RGRT using the trigger mode, real time monitoring is required with well educated respiration.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.