• Title/Summary/Keyword: Breath test

Search Result 169, Processing Time 0.044 seconds

Effect of Bad Breath on Olfactory Identification Ability and on Olfactory Detection Threshold for CH3SH (구취가 후각인지도 및 methyl mercaptan에 대한후각감지역치에 미치는 영향)

  • Do, Young-Hwan;Choi, Jae-Kap;Ahn, Hyoung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.4
    • /
    • pp.309-318
    • /
    • 2001
  • The purposes of the study were (1) to evaluate the olfactory identification ability in those who have bad breath, (2) to determine the olfactory detection threshold for methyl mercaptan in normal subjects and those who have bad breath, and (3) to evaluate the effect of oral hygiene care on the olfactory detection threshold for methyl mercaptan. Sixteen male subjects with bad breath (male odor group), 9 male subjects without bad breath (male non-odor group), and 10 female subjects without bad breath (female non-odor group) were included for the study. Olfactory identification ability was assessed by administrating the Cross-Cultural Smell Identification Test (CC-SIT), and the olfactory detection threshold for methyl mercaptan was measured by two-alternative forced-choice single-staircase detection threshold procedure in a double-blinded condition. The geometric mean of the last four staircase reversal points of a total of seven reversals is used as the threshold. For the male odor group, after 1 month of intensive oral hygiene care for reducing oral volatile sulfur compounds (VSC) concentration, the olfactory detection threshold for methyl mercaptan was measured again and compared to the initial value. The ANOVA was used to test the group difference of olfactory threshold and olfactory identification ability and the paired t-test was used to test the difference of olfactory threshold between before and after reduction of oral VSC in male odor group. The results were as follows : 1. There was no significant difference in olfactory identification ability among those who have bad breath and normal male or female subjects. 2. The olfactory detection threshold for methyl mercaptan was about 8.4 ppb in normal male and female. 3. There was a tendency that male subjects with bad breath showed a higher olfactory detection threshold for methyl mercaptan when compared to those of no bad breath. 4. The olfactory detection threshold for methyl mercaptan returned to a normal level after 1 month of intensive oral hygiene care for reducing oral VSC.

  • PDF

Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

  • Hyung Jin Choun;Jung-in Kim;Jong Min Park;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.136-141
    • /
    • 2022
  • Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The breath control training system comprises a sensor device and software. The sensor device uses a loadcell sensor and an adjustable strap around the chest to acquire respiratory signals. The device connects via Bluetooth to a computer where the software is installed. The software visualizes the respiratory signal in near real-time with a graph. The developed system can signal patients through visual (software), auditory (buzzer), and tactile (vibrator) stimulation when breath-holding starts. A motion phantom was used to test the basic functions of the developed breath control training system. The relative standard deviation of the maxima of the emulated free breathing data was calculated. Moreover, a relative standard deviation of a breath-holding region was calculated for the simulated breath-holding data. Results: The average force of the maxima was 487.71 N, and the relative standard deviation was 4.8%, while the average force of the breath hold region was 398.5 N, and the relative standard deviation was 1.8%. The data acquired through the sensor was consistent with the motion created by the motion phantom. Conclusions: We have developed a breath control training system comprising a sensor device and software that allow patients to learn breath-hold techniques in their convenient environment.

A Pilot Study on the Psychological and Physical Responses of Breath - Counting Meditations (수식관 명상의 심리적 신체적 반응 연구 - 단일군)

  • Lee, Jae-Hyok
    • Journal of Oriental Neuropsychiatry
    • /
    • v.25 no.1
    • /
    • pp.47-54
    • /
    • 2014
  • Objectives: The purpose of this research was to analyze the responses of breath-counting meditations with the psychological test and the physical index. Methods: Breath-counting meditation was applied to 10 normal adults. Then, clinical research State-Trait Anxiety Inventory (STAI), State-Trait Anger eXpression Inventory (STAXI), Psychosocial Well-being Index Short Form (PWI-SF), Brief Encounter Psychosocial Instrument-Korean version (BEPSI-K), Heart Rate Variability (HRV), and Vital Signs (V/S) were carried out to analyze the responses of breath-counting meditations. Results: 1) Systolic Blood Pressure (SBP) decreased on the fifteenth day of breath-counting meditation, and Body Temperature (BT) increased on the fifteenth day. In addition, respiration decreased throughout the period of breath-counting meditation. 2) Standard deviations of N-N interval and Total Power (TP) of HRV all significantly increased on the fifteenth day of breath-counting meditation. 3) Scores of STAI1, STAXI1, STAXI2, and PWI-SF decreased after the breath-counting meditation. Conclusions: The results suggested that breath-counting meditations have positive responses to anger, anxiety and stress.

Delayed Analysis of Hydrogen-Methane Breath Samples

  • Willemsen, Marjolein;Van De Maele, Kristel;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.25 no.1
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose: Hydrogen-methane breath tests are used to diagnose carbohydrate malabsorption and small intestinal bacterial overgrowth. The COVID-19 pandemic has driven the modification of procedures as breath tests are potentially aerosol-generating procedures. We assessed the effect of delayed analysis of breath samples, facilitating the at-home performance of breath testing. Methods: Children provided two breath samples at every step of the lactose breath test. The samples were brought back to the clinic, and one set of samples was analyzed immediately. The second set was stored at room temperature and analyzed 1-4 days later. Results: Out of the 73 "double" lactose breath tests performed at home, 33 (45.8%) were positive. The second samples were analyzed 20 to 117 hours after the first samples (41.7±24.3 hours). There was no significant difference in the hydrogen concentration between the first and second sets (Z=0.49, p=0.62). This was not the case for methane, which had a significantly higher concentration in the second breath samples (Z=7.6). Conclusion: Expired hydrogen levels remain stable in plastic syringes if preserved at room temperature for several days. On the other hand, the delayed analysis of methane appeared to be less reliable. Further research is needed to examine the impact of delayed analysis on methane and hydrogen concentrations.

The Study of Breath Competence Depending on Utterance Condition by Healthy Speakers: a Preliminary Study (발화조건에 따른 정상 성인의 호흡 능력 차이 비교: 예비연구)

  • Lee, In-Ae;Lee, Hye-Eun;Hwang, Young-Jin
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • This study sought to compare breath competence in three different utterance conditions when reading a passage aloud, making a spontaneous speech, and singing. We tested 15 normal females (ages averaging $24{\pm}4.4$) and measured breath competence through an objective, aero-mechanical instrument called PAS (Phonatory aerodynamic system, model 6600, KAY Electronics, Inc). Breathing sets of inspiration and expiration were measured by breath group number, breath group duration, and the ratio of inspiration to expiration. The results from this study led us to the following conclusion: The breath group number and the breath group duration showed no significant difference. However, the only variance that we could find was in the ratio of inspiration and expiration. In significantly different speech patterns, singing resulted in the most varied ratio of inspiration and expiration, followed by reading a text aloud, and spontaneous speech. The average frequency rates and maximum intensity levels varied with regards to varying utterance conditions. This thus shows that breath competence and phonation competence have a closely interrelated relationship.

The study of mechanical human respiratory simulator via characteristic test of motor and proportional valve (모터와 비례제어 밸브의 특성실험을 통한 기계적 호흡 모사장치연구)

  • Lee, M.K.;Lee, T.S.;Chi, S.H.;Oh, S.K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.492-495
    • /
    • 2008
  • As the obesity patients increase recently, breath disease such an OSA(obstructive sleep apnea) is also increasing. When the breath disease occurs, the risk comes to be high. Dependence degree the PAP(positive airway pressure) is also coming to be high. The mechanical simulator is composed cylinder, valve, ball screw and the motor that they correspond to the lung and airway, the diaphragm of the human. In order to confirm the characteristic of the motor and the valve, it accomplished an test. The simulator traces breath pattern against the normal breath and the OSA.

  • PDF

Changes in Visual Acuity and Values of Objective Refraction with Breath Alcohol Concentration (호흡 알코올 농도에 따른 시력과 타각적 굴절검사 값의 변화)

  • Jung, Su A;Nam, Soo-Kyung;Kim, Hyun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.187-193
    • /
    • 2015
  • Purpose: This study was aimed to investigate effects of increased breath alcohol concentration (BrAC) which is the standard measurement of alcohol consumption in sobriety test under current laws on visual acuity and values of objective refraction. Methods: For twenty three males in 20s (average age $21.17{\pm}2.19$ years, body mass index (BMI) $22.09{\pm}2.16$) were selected. Distance and near visual test was performed at BrAC of 0%, 0.05% and 0.08%, and objective refraction with open-field auto-refractometer was also performed at different BrAC. Results: As breath alcohol concentration is increased, distance visual acuity was decreased, which was statistically significant, but near visual acuity was not changed. Also, values of objective refraction tended to be increased towards minus as breath alcohol concentration is increased. Conclusions: As breath alcohol concentration is increased, corrected visual acuity is decreased and refractive power is towards minus, it is necessary that visual acuity test and refraction measurement should be conducted under sober condition.

Analysis of Acetone Absorption Spectra Using Off-axis Integrated Cavity Output Spectroscopy for a Real-time Breath Test

  • Lim Lee;Yonghee Kim;Byung Jae Chun;Taek-Soo Kim;Seung-Kyu Park;Kwang-Hoon Ko;Ki-Hee Song;Hyunmin Park
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.761-765
    • /
    • 2023
  • We analyzed the absorption spectra of acetone in the 3.37 ㎛ mid-infrared range using the off-axis integrated cavity output spectroscopy technique to develop a real-time, in-line breath analysis device. The linear relationship between acetone concentration and absorption increase was confirmed as 0.32%/ppm, indicating that the developed device allows for a quantitative analysis of acetone concentration in exhaled breath. To further confirm the feasibility of using our device for breath analysis, we measured the acetone concentration of human breath samples at the sub-ppm level.

Effects of Breath and Exhaust on the Performance of a Reciprocating Engine for Small Aircraft (소형항공기용 왕복엔진의 성능에 관한 흡/배기 영향)

  • 김근배;김근택;최선우
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.37-40
    • /
    • 2002
  • The engine performance test was carried out to investigate the effects of breath and exhaust on the performance of a reciprocating engine for small aircraft. In this test, three valves to control flow areas of a inlet and two outlets were used, the engine manifold pressure and the static thrust of propeller were measured in nine breath/exhaust conditions. Generally, small variations on the performance were showed as the test conditions were changed. The manifold pressure was increased as flow area of the inlet or the outlet was decreased in normal condition, however it was decreased as both flow areas were decreased. The static thrust of propeller was showed similar as the manifold pressure.

  • PDF

The Effects of Stabilization Exercise with Abdominal Breath on Balance and Oswestry Disability Index for Low Back Pain Patients (복식호흡을 병행한 척추 안정화운동이 요통환자의 균형능력과 오스웨스트리 장애지수에 미치는 영향)

  • Son, Ho-Hee
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.1
    • /
    • pp.107-113
    • /
    • 2015
  • PURPOSE: This study was to investigate the effect of stabilization exercise with abdominal breath on Balance and Oswestry Disability Index for Low Back Pain Patients. METHODS: The subjects were 18 low back pain patients in their twenties. The subjects were randomly assigned into experimental group and control group. Control group and experimental group both participated in 30 minutes of stabilization exercise for 8 weeks(5 times/week), and experimental group participated in stabilization exercise with abdominal breath. The subjects were tested balance and pain using BioRescue and Oswestry Diability Index respectively, before and after intervention. RESULTS: The experimental group showed a statistical significance in movement areas of the body's center(p<.05), but there was no significant differences between groups (p>.05). The experimental group showed a statistical significance in movement distances of the body's center with eyes open(p<.05), and there was significant differences between groups(p<.05). Both groups showed a statistical significance in ODI between pre and post test(p<.05) but there was no significant differences between groups(p>.05). CONCLUSION: As a result, the group participating in stabilization exercise with abdominal breath had a more effective improvement than the control group. Therefore, the stabilization exercise with abdominal breath may be used improving balance and pain in low back pain patients.