• Title/Summary/Keyword: Breast-Tool

Search Result 149, Processing Time 0.027 seconds

Breast Cancer Screening Barriers from the Womans Perspective: a Meta-synthesis

  • Azami-Aghdash, Saber;Ghojazadeh, Morteza;Sheyklo, Sepideh Gareh;Daemi, Amin;Kolahdouzan, Kasra;Mohseni, Mohammad;Moosavi, Ahmad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3463-3471
    • /
    • 2015
  • Background: The principal aim of health service providers in the field of breast cancer is to detect and treat lesions at an appropriate time. Therefore, identification of barriers to screening can be very helpful. The present study aimed to systematically review the qualitative studies for extracting and reporting the barriers of screening for breast cancer from the womans perspective. Materials and Methods: In this systematic review; Pubmed, Google Scholar, Ovid Scopus, Cochrane Library, Iranmedex, and SID were searched using the keywords: screening barriers, cancer, qualitative studies, breast and their Persian equivalents, and the needed data were extracted and analyzed using an extraction table. To assess the quality of the studies, the Critical Appraisal Skills Programme (CASP) tool was used. Results: From 2,134 related articles that were found, 21 articles were eventually included in the study. The most important barriers from the point of view of 1,084 women were lack of knowledge, access barriers (financial, geographical, cultural), fear (of results and pain), performance of service providers, women's beliefs, procrastination of screening, embarrassment, long wait for getting an appointment, language problems, and previous negative experiences. Articles' assessment score was 68.9. Conclusions: Increasing women's knowledge, reducing the costs of screening services, cultural promotion for screening, presenting less painful methods, changing beliefs of health service providers, provision of privacy for giving service, decreasing the waiting time, and providing high quality services in a respectful manner can be effective ways to increase breast cancer screening.

ZR-75-1 human breast cancer cells th study the mechanism of action of PAHs

  • Nano, Min-Kyung;Yhong, Sheen-Yhun
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2002.10a
    • /
    • pp.171-171
    • /
    • 2002
  • Recent industrial society has human widely exposed to PAHs that are comming from the incomplete combustion of organic material as widerspread environmetal contaminants. Biological activities of PAHs are not known although PAHs are considered as carcinogens. PAHs in the mammalian cells affect CYP1A1 gene expression as well as other phase II drug metabolizing enzymes as UDPGT, NMOR etc. The mechanism of action of PAHs has been studied extensively, however it is not clear how PAHs turn on CYP1A1 in human breast cancer. Our labolatory have been studied the effect of PAHs in the human breast cancer cell lind MCF7. In this study, we examined the ZR-75-1 human breast cancer cells as a new system to evaluate bioactivity of PAHs. ZR-75-1 human breast cancer cell line has been estabilished from the breast cnacer patient, has estrogen receptors and progesteron receptors. We have been able to estbilish long term culture system of this cells then used for the study to observe the effect of PAHs. We demonstrate that PAHs induced the transcription of an aryl hydrocarbon-responsive reporter vector containing the CYP1A1 promoter and 7-ethoxyresolufin O-deethylase(EROD) activity of CYP1A1 enzyme in a concentration-dependant manner. RT-PCR analysises indicated that PAHs significantly up-regulate the constitutive level of CYP1A1 mRNA. Apparently, ZR-75-1 cells have Aryl hydrocarbon recetors, therefore it would be good experimental tool to study the cross-talk between PAHs and steroid actions.

  • PDF

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.

Automated Versus Handheld Breast Ultrasound for Evaluating Axillary Lymph Nodes in Patients With Breast Cancer

  • Sun Mi Kim;Mijung Jang;Bo La Yun;Sung Ui Shin;Jiwon Rim;Eunyoung Kang;Eun-Kyu Kim;Hee-Chul Shin;So Yeon Park;Bohyoung Kim
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.146-156
    • /
    • 2024
  • Objective: Automated breast ultrasound (ABUS) is a relevant imaging technique for early breast cancer diagnosis and is increasingly being used as a supplementary tool for mammography. This study compared the performance of ABUS and handheld ultrasound (HHUS) in detecting and characterizing the axillary lymph nodes (LNs) in patients with breast cancer. Materials and Methods: We retrospectively reviewed the medical records of women with recently diagnosed early breast cancer (≤ T2) who underwent both ABUS and HHUS examinations for axilla (September 2017-May 2018). ABUS and HHUS findings were compared using pathological outcomes as reference standards. Diagnostic performance in predicting any axillary LN metastasis and heavy nodal-burden metastases (i.e., ≥ 3 LNs) was evaluated. The ABUS-HHUS agreement for visibility and US findings was calculated. Results: The study included 377 women (53.1 ± 11.1 years). Among 385 breast cancers in 377 patients, 101 had axillary LN metastases and 30 had heavy nodal burden metastases. ABUS identified benign-looking or suspicious axillary LNs (average, 1.4 ± 0.8) in 246 axillae (63.9%, 246/385). According to the per-breast analysis, the sensitivity, specificity, positive and negative predictive values, and accuracy of ABUS in predicting axillary LN metastases were 43.6% (44/101), 95.1% (270/284), 75.9% (44/58), 82.6% (270/327), and 81.6% (314/385), respectively. The corresponding results for HHUS were 41.6% (42/101), 95.1% (270/284), 75.0% (42/56), 82.1% (270/329), and 81.0% (312/385), respectively, which were not significantly different from those of ABUS (P ≥ 0.53). The performance results for heavy nodal-burden metastases were 70.0% (21/30), 89.6% (318/355), 36.2% (21/58), 97.3% (318/327), and 88.1% (339/385), respectively, for ABUS and 66.7% (20/30), 89.9% (319/355), 35.7% (20/56), 97.0% (319/329), and 88.1% (339/385), respectively, for HHUS, also not showing significant difference (P ≥ 0.57). The ABUS-HHUS agreement was 95.9% (236/246; Cohen's kappa = 0.883). Conclusion: Although ABUS showed limited sensitivity in diagnosing axillary LN metastasis in early breast cancer, it was still useful as the performance was comparable to that of HHUS.

Diagnostic Role of Tc-99m MIBI Scintimammography in Suspected Breast Cancer Patients: Results of Unicenter Trial (유방암이 의심되는 환자에서 Tc-99m MIBI 유방스캔의 진단적 역할: 단일기관의 결과)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.3
    • /
    • pp.234-242
    • /
    • 2000
  • Purpose: Tc-99m MIBI scintimammography has been validated as an useful non-invasive diagnostic tool for the primary breast cancer. But most studies have included small population of patients. We have experienced a large study population and investigated the diagnostic usefulness of Tc-99m MIBI scintimammography in detection of primary breast cancer and axillary lymph node metastasis. Materials and Methods: This study included 305 patients who underwent scintimammogtaphy for palpable breast masses or abnormal radiologic findings. Tc-99m MIBI scintimammography was performed 10 minutes after intravenous injection of 925 MBq of Tc-99m MIBI. If the early image revealed abnormal finding, 3 hour delayed image was also acquired. We calculated early and delayed lesion to non-lesion ratios (L/N). The pathologic diagnosis was obtained from surgical operation or FNAB and compared with the results of Tc-99m MIBI scintimammography. Results: Malignant breast diseases were 155 and benign ones were 150. Tc-99m MIBI scintimammography revealed 132 true positive, 23 false negative, 10 false positive, and 140 true negative cases. The sensitivity, specificity, positive predictive value and negative predictive value for the primary breast cancer detection were 85.2%, 93.4%, 92.9%, and 85.9%, respectively. The sensitivity, specificity, positive predictive and negative predictive values of Tc-99m MIBI scintimammography in detecting metastatic axillary lymph node involvement were 22%, 90.4%, 61.9% and 62.3%, respectively. Early L/N of malignant breast disease was significantly higher than that of benign one ($2.44{\pm}0.97\;vs\;1.94{\pm}0.78$, p=0.01). Delayed L/N had no significant difference between malignant and benign breast diseases ($1.94{\pm}0.52\;vs\;1.91{\pm}0.73$, p=0.43). Conclusion: Our study revealed that Tc-99m MIBI scintimammography was an useful diagnostic tool for the diagnosis of breast cancer. And early L/N ratio might provide complementary role in the detection of breast cancer. But the Tc-99m MIBI scintimammography had limited value in the detection of small breast cancer (less than 1 cm) and axillary lymph node metastasis.

  • PDF

Color Texture Analysis as a Tool for Quantitative Evaluation of Radiation-Induced Skin Injuries

  • Sung Young Lee;Jin Ho Kim;Ji Hyun Chang;Jong Min Park;Chang Heon Choi;Jung-in Kim;So-Yeon Park
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.144-152
    • /
    • 2023
  • Background: Color texture analysis was applied as a tool for quantitative evaluation of radiation-induced skin injuries. Materials and Methods: We prospectively selected 20 breast cancer patients who underwent whole-breast radiotherapy after breast-conserving surgery. Color images of skin surfaces for irradiated breasts were obtained by using a mobile skin analyzer. The first skin measurement was performed before the first fraction of radiotherapy, and the subsequent measurement was conducted approximately 10 days after the completion of the entire series of radiotherapy sessions. For comparison, color images of the skin surface for the unirradiated breasts were measured similarly. For each color image, six co-occurrence matrices (red-green [RG], red-blue [RB], and green-blue [GB] from color channels, red [R], green [G], blue [B] from gray channels) can be generated. Four textural features (contrast, correlation, energy, and homogeneity) were calculated for each co-occurrence matrix. Finally, several statistical analyses were used to investigate the performance of the color textural parameters to objectively evaluate the radiation-induced skin damage. Results and Discussion: For the R channel from the gray channel, the differences in the values between the irradiated and unirradiated skin were larger than those of the G and B channels. In addition, for the RG and RB channels, where R was considered in the color channel, the differences were larger than those in the GB channel. When comparing the relative values between gray and color channels, the 'contrast' values for the RG and RB channels were approximately two times greater than those for the R channel for irradiated skin. In contrast, there were no noticeable differences for unirradiated skin. Conclusion: The utilization of color texture analysis has shown promising results in evaluating the severity of skin damage caused by radiation. All textural parameters of the RG and RB co-occurrence matrices could be potential indicators of the extent of skin damage caused by radiation.

Accuracy of Digital Breast Tomosynthesis for Detecting Breast Cancer in the Diagnostic Setting: A Systematic Review and Meta-Analysis

  • Min Jung Ko;Dong A Park;Sung Hyun Kim;Eun Sook Ko;Kyung Hwan Shin;Woosung Lim;Beom Seok Kwak;Jung Min Chang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1240-1252
    • /
    • 2021
  • Objective: To compare the accuracy for detecting breast cancer in the diagnostic setting between the use of digital breast tomosynthesis (DBT), defined as DBT alone or combined DBT and digital mammography (DM), and the use of DM alone through a systematic review and meta-analysis. Materials and Methods: Ovid-MEDLINE, Ovid-Embase, Cochrane Library and five Korean local databases were searched for articles published until March 25, 2020. We selected studies that reported diagnostic accuracy in women who were recalled after screening or symptomatic. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. A bivariate random effects model was used to estimate pooled sensitivity and specificity. We compared the diagnostic accuracy between DBT and DM alone using meta-regression and subgroup analyses by modality of intervention, country, existence of calcifications, breast density, Breast Imaging Reporting and Data System category threshold, study design, protocol for participant sampling, sample size, reason for diagnostic examination, and number of readers who interpreted the studies. Results: Twenty studies (n = 44513) that compared DBT and DM alone were included. The pooled sensitivity and specificity were 0.90 (95% confidence interval [CI] 0.86-0.93) and 0.90 (95% CI 0.84-0.94), respectively, for DBT, which were higher than 0.76 (95% CI 0.68-0.83) and 0.83 (95% CI 0.73-0.89), respectively, for DM alone (p < 0.001). The area under the summary receiver operating characteristics curve was 0.95 (95% CI 0.93-0.97) for DBT and 0.86 (95% CI 0.82-0.88) for DM alone. The higher sensitivity and specificity of DBT than DM alone were consistently noted in most subgroup and meta-regression analyses. Conclusion: Use of DBT was more accurate than DM alone for the diagnosis of breast cancer. Women with clinical symptoms or abnormal screening findings could be more effectively evaluated for breast cancer using DBT, which has a superior diagnostic performance compared to DM alone.

Linkages of nursing Diagnosis, Nursing Intervention and Nursing Outcome Classification of Breast Cancer Patients using Nursing Database (간호데이터베이스를 이용한 유방암환자의 간호진단, 간호중재, 간호결과 분류연계)

  • Chi, Mi-Kyung;Chi, Sung-Ai
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.9 no.4
    • /
    • pp.651-661
    • /
    • 2003
  • Purpose: This is the descriptive research project of which purpose is to acquire the practice, research, and educational data by establishing the database after confirming, classifying, and relating the nursing diagnosis, nursing intervention, and nursing outcome of Breast cancer patients by using the Yoo Hyung-sook's(2001) related 3N database model as the tool. Method : The Nursing Data occurring on Breast cancer patients nursing process was mapped to nursing diagnosis of NANDA, nursing interventions of NIC, nursing outcomes of NOC the 3N database linkage database which is related with the nursing process that was developed by using Yoo Hyung-sook's(2001). Result : 1. The nursing diagnosis were totally 505, and 26 articles of the nursing diagnosis were applied among 149 nursing diagnosis classification systems. 2. As for the nursing intervention, 250 articles(5l.4%) of nursing intervention were applied among 486 nursing intervention classification systems. 3. Regarding the nursing outcome, 28 articles(1l.2%l of the nursing outcome were applied among 250 nursing outcome classification systems. Conclusion: The result of this research in which the relating among the nursing diagnosis, nursing intervention, and nursing outcome of Breast cancer patients by using 3N nursing database was established is thought to be applied in the research and practice as well as to be utilized in the lecture or practice of the nursing process.

  • PDF

Value of Fine Needle Aspiration Cytology of Mucinous Carcinoma of the Breast (유방의 점액성 암종의 진단시 세침흡인 검사의 의의)

  • Kim, Yoon-Jung;Gong, Gyung-Yub;Huh, Joo-Ryung;Park, Jeong-Mi;Ahn, Sei-Hyun;Kim, On-Ja
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.157-162
    • /
    • 1996
  • Fine needle aspiration(FNA) is an effective tool in diagnosing mammary carcinoma. We experienced 7 cases of histologically confirmed mammary mucinous carcinoma among 3,052 aspirated cases of breast from 1992 to 1996 in Asan Medical Center. The average age of the patient was 48(33-64) years. The mean size of the lesions was $1.6(0.7{\sim}3)cm$, and they were palpated as well-defined, firm to hard masses. The cytologic features that may be useful in making a FNA diagnosis of mucinous carcinoma of the breast were analysed. Mucinous background and tumor cell clusters with occasional single cells were observed in all cases. Among them, two cases showed abundant scattered single cells, whereas only few single cells were seen in the other two cases. Tumor cells exhibited mild pleomorphism in four cases and moderate pleomorphism in three cases. Nucleoli tended to be not prominent and are observed in three cases, rarely noted in other three cases and not seen in one. There was microcalcification in four cases(57%). In conclusion, mucinous background and clustered tumor cells showing mild to moderate pleomorphism with characteristic clinical findings allow us to diagnose mucinous carcinoma of the breast.

  • PDF

The effect of PAHs on the regualtion of CYP1 gene in ZR-75-1 and MCF7 human breast cancer cells

  • Min, K.N.;Sheen, Yhun Y.;Kim, J.Y.;Cho, M.J.
    • Proceedings of the Korea Society of Environmental Toocicology Conference
    • /
    • 2003.05a
    • /
    • pp.193-193
    • /
    • 2003
  • Recent industrial society has human widely exposed to PAHs that are coming from the incomplete combustion of organic material as widespread environmental contaminants. Biological activities of PAHs are not known although PAHs are considered as carcinogens. The mechanism of action of PAHs has been studied extensively, however it is not clear how PAHs turn on CYPlAl in human breast cancer, Our laboratory have been studied the effect of PAHs in the human breast cancer cells, MCF-7. In this study, we examined the ZR-75-1, human breast cancer cells, as a new system to evaluate bioactivity of PAHs and to compare the PAHs action with that of MCF-7 cells. ZR-75-1 human breast cancer cell line is responsible to estrogen and progesterone. We have been able to establish long term culture system of this cells then used for the study to the effect of 13 different PAHs and environmental samples. We demonstrate that PAHs induced the CYP1A1 promoter and 7-ethoxyresorufin O-deethylase (EROD) activity in a concentration-dependent manner. RT-PCR analysis indicated that PAHs significantly up-regulate the level of CYP1A1 mRNA. Some of PAHs showed stronger stimulatory effect on CYP1 gene expression than TCDD Apparently, ZR-75-1 cells have Aryl hydrocarbon receptors (AhR), therefore it would be a good experimental tool to study the cross-talk between PAHs and steroid actions.

  • PDF