• 제목/요약/키워드: Breast magnetic resonance imaging

검색결과 122건 처리시간 0.024초

Recurrent Encapsulated Papillary Carcinoma in the Ipsilateral Internal Mammary Lymph Node: a Case Report

  • Jung, Chi Hyung;Kim, You Me;Kim, Hee Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제26권1호
    • /
    • pp.43-47
    • /
    • 2022
  • Encapsulated papillary carcinoma (EPC) is an uncommon breast malignancy that is known to be indolent and associated with an excellent prognosis. However, there is a rare possibility of locoregional relapse or metastasis. Here, we present a case of recurrent EPC in the ipsilateral internal mammary lymph node (IMLN) that was detected in the postoperative magnetic resonance imaging with abbreviated protocol (AB-MRI). AB-MRI could facilitate the early detection of recurrent disease in the IMLN and may provide prognostic gain for such patients.

Breast Magnetic Resonance Imaging Indications in Current Practice

  • Taif, Sawsan Abdulkareem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.569-575
    • /
    • 2014
  • Although mammography is the primary imaging modality for the breast, it has its limitations especially with dense breast parenchyma. Breast magnetic resonance imaging (MRI) has evolved into an important adjunctive tool as it is currently the most sensitive technique for breast cancer detection. Despite this high sensitivity, overlap in the appearances of some benign and malignant breast lesions results in additional unnecessary intervention with negative results. These false positives, in addition to high cost and limited availability, necessitate establishing proper indications for breast MRI. The literature was here reviewed for recent clinical trials, meta-analyses and review papers which have studied this important subject. PubMed; the US national library of medicine, was utilized to review the literature in the last twenty years. Using the obtained information, current uses of breast MRI are discussed in this paper to determine the indications which are relevant to clinical practice.

Diffusion-Weighted Magnetic Resonance Imaging of the Breast: Standardization of Image Acquisition and Interpretation

  • Su Hyun Lee;Hee Jung Shin;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.9-22
    • /
    • 2021
  • Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a rapid, unenhanced imaging technique that measures the motion of water molecules within tissues and provides information regarding the cell density and tissue microstructure. DW MRI has demonstrated the potential to improve the specificity of breast MRI, facilitate the evaluation of tumor response to neoadjuvant chemotherapy and can be employed in unenhanced MRI screening. However, standardization of the acquisition and interpretation of DW MRI is challenging. Recently, the European Society of Breast Radiology issued a consensus statement, which described the acquisition parameters and interpretation of DW MRI. The current article describes the basic principles, standardized acquisition protocols and interpretation guidelines, and the clinical applications of DW MRI in breast imaging.

Periductal Stromal Sarcoma of the Breast: a Case Report

  • Kim, Yoon Ha;Lee, Jee Young;Kim, You Me
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권4호
    • /
    • pp.269-272
    • /
    • 2017
  • Periductal stromal sarcoma (PSS) is a type of rare malignant fibroepithelial tumor. PSS is a recently introduced diagnostic entity and there are few reports about radiological features of this tumor. Pre-operative diagnosis is difficult because it reveals similar symptoms with other benign and malignant tumors with absence of specific radiologic findings. We present a woman age 30 that underwent mammotome biopsy for a BI-RADS 4 lesion on her left breast and received histopathology diagnosis of a phyllodes tumor. Additionally, she underwent a wide excision depending on her histopathology diagnosis. Her final diagnosis was PSS. Six months later, no recurrence was detected. However, frequent follow-up is needed because PSS can develop into phyllodes tumor or entity of breast cancer.

유방에 발생한 일차성 비호지킨림프종의 자기공명 분광법 및 확산강조 영상: 2예 (MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports)

  • 남상유;유은영;최혜영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제18권2호
    • /
    • pp.176-181
    • /
    • 2014
  • 유방의 일차성 비호지킨림프종은 드문 종양으로 유방촬영술과 초음파에서 다양한 영상소견을 보인다. 하지만 자기공명영상소견은 여러개의 증례로만 보고되어 있고, 자기공명분광법과 확산강조영상에 대한 보고는 거의 없다. 저자들은 유방의 일차성 비호지킨림프종을 진단받은 두명의 여자환자의 증례를 기본 자기공명영상에 더하여 자기공명 분광법 및 확산강조 영상소견과 함께 보고하고자 한다. 종양은 유방촬영술과 초음파에서 경계가 좋은 종괴로 나타났으며, 조영증강자기공명영상에서 강한 조영증강을 보였다. 또한 다른 악성종양에서 나타나는 것과 같이 확산강조영상에서는 확산제한을 보이고, 자기공명분광법에서는 콜린값이 증가하는 소견을 보였다.

Magnetic Resonance Imaging-Based Volumetric Analysis and Its Relationship to Actual Breast Weight

  • Yoo, Anna;Minn, Kyung Won;Jin, Ung Sik
    • Archives of Plastic Surgery
    • /
    • 제40권3호
    • /
    • pp.203-208
    • /
    • 2013
  • Background Preoperative volume assessment is useful in breast reconstruction. Magnetic resonance imaging (MRI) and mammography are commonly available to reconstructive surgeons in the care of a patient with breast cancer. This study aimed to verify the accuracy of breast volume measured by MRI, and to identify any factor affecting the relationship between measured breast volume and actual breast weight to derive a new model for accurate breast volume estimation. Methods From January 2012 to January 2013, a retrospective review was performed on a total of 101 breasts from 99 patients who had undergone total mastectomy. The mastectomy specimen weight was obtained for each breast. Mammographic and MRI data were used to estimate the volume and density. A standard statistical analysis was performed. Results The mean mastectomy specimen weight was 340.8 g (range, 95 to 795 g). The mean MRI-estimated volume was $322.2mL^3$. When divided into three groups by the "difference percentage value", the underestimated group showed a significantly higher fibroglandular volume, higher percent density, and included significantly more Breast Imaging, Reporting and Data System mammographic density grade 4 breasts than the other groups. We derived a new model considering both fibroglandular tissue volume and fat tissue volume for accurate breast volume estimation. Conclusions MRI-based breast volume assessment showed a significant correlation with actual breast weight; however, in the case of dense breasts, the reconstructive surgeon should note that the mastectomy specimen weight tends to overestimate the volume. We suggested a new model for accurate breast volume assessment considering fibroglandular and fat tissue volume.

Use of Magnetic Resonance Imaging for Evaluating Residual Breast Tissue After Robotic-Assisted Nipple-Sparing Mastectomy in Women With Early Breast Cancer

  • Wen-Pei Wu;Hung-Wen Lai;Chiung-Ying Liao;Joseph Lin;Hsin-I Huang;Shou-Tung Chen;Chen-Te Chou;Dar-Ren Chen
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.640-646
    • /
    • 2023
  • Objective: Prospective studies on postoperative residual breast tissue (RBT) after robotic-assisted nipple-sparing mastectomy (R-NSM) for breast cancer are limited. RBT presents an unknown risk of local recurrence or the development of new cancer after curative or risk-reducing mastectomies. This study investigated the technical feasibility of using magnetic resonance imaging (MRI) to evaluate RBT after R-NSM in women with breast cancer. Materials and Methods: In this prospective pilot study, 105 patients, who underwent R-NSM for breast cancer at Changhua Christian Hospital between March 2017 and May 2022, were subjected to postoperative breast MRI to evaluate the presence and location of RBT. The postoperative MRI scans of 43 patients (age, 47.8 ± 8.5 years), with existing preoperative MRI scans, were evaluated for the presence and location of RBT. In total, 54 R-NSM procedures were performed. In parallel, we reviewed the literature on RBT after nipple-sparing mastectomy, considering its prevalence. Results: RBT was detected in 7 (13.0%) of the 54 mastectomies (6 of the 48 therapeutic mastectomies and 1 of the 6 prophylactic mastectomies). The most common location for RBT was behind the nipple-areolar complex (5 of 7 [71.4%]). Another RBT was found in the upper inner quadrant (2 of 7 [28.6%]). Among the six patients who underwent RBT after therapeutic mastectomies, one patient developed a local recurrence of the skin flap. The other five patients with RBT after therapeutic mastectomies remained disease-free. Conclusion: R-NSM, a surgical innovation, does not seem to increase the prevalence of RBT, and breast MRI showed feasibility as a noninvasive imaging tool for evaluating the presence and location of RBT.

Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging

  • Bo Ra Kwon;Jung Min Chang;Soo-Yeon Kim;Su Hyun Lee;Sung Ui Shin;Ann Yi;Nariya Cho;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제21권11호
    • /
    • pp.1210-1219
    • /
    • 2020
  • Objective: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of handheld ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). Materials and Methods: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. Results: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). Conclusion: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions.

Impact of Radiotherapy on Background Parenchymal Enhancement in Breast Magnetic Resonance Imaging

  • Kim, Yun Ju;Kim, Sung Hun;Choi, Byung Gil;Kang, Bong Joo;Kim, Hyeon Sook;Cha, Eun Suk;Song, Byung Joo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권7호
    • /
    • pp.2939-2943
    • /
    • 2014
  • Background: While many studies have shown that hormones can influence background parenchymal enhancement (BPE) in breast magnetic resonance imaging (MRI), only few have directly address the effect of radiotherapy. The purpose of this study was to evaluate the impact of radiotherapy on BPE in breast MRI. Materials and Methods: A retrospective search identified 62 women with unilateral breast cancer who had a breast MRI both before and after radiotherapy following breast-conserving surgery. In our study, we assumed that systemic therapy affected both breasts equivalently. We rated the level of BPE of both breasts using a four-point categorical scale. A change in the level of BPE prior to and after treatment was compared in the diseased and contralateral breasts. Results: All patients received a 4256 to 6480 cGy dose of whole breast radiotherapy over 3-7 weeks. The mean timing of the follow-up study was 6.6 months after completion of radiotherapy. Although the BPE showed a decrease in both breasts after treatment, there was a significant reduction of BPE in the irradiated breast compared with the contralateral breast (1.18 versus 0.98 average reduction in BPE level, p=0.042). Conclusions: Radiotherapy is associated with decrease in BPE with MRI.

Diagnostic Accuracy of Magnetic Resonance Imaging Features and Tumor-to-Nipple Distance for the Nipple-Areolar Complex Involvement of Breast Cancer: A Systematic Review and Meta-Analysis

  • Jung Hee Byon;Seungyong Hwang;Hyemi Choi;Eun Jung Choi
    • Korean Journal of Radiology
    • /
    • 제24권8호
    • /
    • pp.739-751
    • /
    • 2023
  • Objective: This systematic review and meta-analysis evaluated the accuracy of preoperative breast magnetic resonance imaging (MRI) features and tumor-to-nipple distance (TND) for diagnosing occult nipple-areolar complex (NAC) involvement in breast cancer. Materials and Methods: The MEDLINE, Embase, and Cochrane databases were searched for articles published until March 20, 2022, excluding studies of patients with clinically evident NAC involvement or those treated with neoadjuvant chemotherapy. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Two reviewers independently evaluated studies that reported the diagnostic performance of MRI imaging features such as continuity to the NAC, unilateral NAC enhancement, non-mass enhancement (NME) type, mass size (> 20 mm), and TND. Summary estimates of the sensitivity and specificity curves and the summary receiver operating characteristic (SROC) curve of the MRI features for NAC involvement were calculated using random-effects models. We also calculated the TND cutoffs required to achieve predetermined specificity values. Results: Fifteen studies (n = 4002 breast lesions) were analyzed. The pooled sensitivity and specificity (with 95% confidence intervals) for NAC involvement diagnosis were 71% (58-81) and 94% (91-96), respectively, for continuity to the NAC; 58% (45-70) and 97% (95-99), respectively, for unilateral NAC enhancement; 55% (46-64) and 83% (75-88), respectively, for NME type; and 88% (68-96) and 58% (40-75), respectively, for mass size (> 20 mm). TND had an area under the SROC curve of 0.799 for NAC involvement. A TND of 11.5 mm achieved a predetermined specificity of 85% with a sensitivity of 64%, and a TND of 12.3 mm yielded a predetermined specificity of 83% with a sensitivity of 65%. Conclusion: Continuity to the NAC and unilateral NAC enhancement may help predict occult NAC involvement in breast cancer. To achieve the desired diagnostic performance with TND, a suitable cutoff value should be considered.