• 제목/요약/키워드: Break-out

검색결과 600건 처리시간 0.028초

직류방식 전기철도에서 강제배류기의 절연협조 (Insulation Coordination of Forced Drainage in Electric Railway)

  • 민병훈;어익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF

인터넷 쇼핑몰의 판매촉진 특성과 성과간의 관련성에 대한 운영형태의 조절효과 (An Empirical Study on the Relationships between Internet Shopping Mall's Sales Promotional Functionality and Performance)

  • 한홍수;정현식
    • 경영과정보연구
    • /
    • 제15권
    • /
    • pp.37-50
    • /
    • 2004
  • Internet commerce has the potential to propel a company to 'break out' of existing strategic constraints and radically alter business processes, strengthen customer and supplier ties, and open up new markets. Therefore, many firms have rushed into internet commerce to conduct business more efficiently, create new business opportunities, and generate business value. The purpose of this study is to examine the relationship between the sales promotional functionality of internet shopping mall and its performance considering the characteristics of internet shopping mall's operational form as moderating variables. The results showed that the price functionality affects positive effects on the performance of shopping mall, and the characteristics of operational form can be considered as a significant moderating variables between the sales promotional functionality of shopping mall and the performance.

  • PDF

중수로 압력관의 수화물이 LBB평가에 미치는 영향 (Effect of Hydride of the PHWR Pressure Tube on the LBB Evaluation)

  • 오동준;김영석
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.610-616
    • /
    • 2004
  • The aim of this study was to investigate the hydride embrittlement when the LBB evaluation was carried out for the integrity of PHWR Pressure Tubes. The transverse tensile and CCT toughness tests were performed at three hydrogen concentrations while the test temperatures were changed (RT to 30$0^{\circ}C$). Both the transverse tensile and the fracture toughness tests showed the hydrogen embitterment clearly at RT but this phenomenon was disappeared while the test temperature arrived at 25$0^{\circ}C$. Using the DHC test results, the CCL and LBB time were calculated and compared. The hydride embrittlement at the LBB evaluation made the LBB time short definedly. If the operating temperature, DHCV and LBB deterministic parameters such as A and m were known, LBB time could be estimated without the calculation of CCL.

구조용강의 용접방법에 따른 부식피로특성 연구 (A Study on Corrosion Fatigue Characteristics Based on Welding Methods of Structural Steel)

  • 박경동;유형주
    • 한국기계가공학회지
    • /
    • 제5권3호
    • /
    • pp.58-64
    • /
    • 2006
  • The security of stability for fractures of all sorts of parts and structure has become a first subject these days. We have need to organize fatigue characteristics of weldment because fatigue break out suddenly without a change of shape. In this study, we execute the fatigue test according to different of the welding method at the same materials. It was investigated about a fatigue limit according to welding methods of SMAW, FCAW and SAW at normal temperature and a frequency of 10Hz. The important results of the experimental study on fatigue characteristics of weldment are as follows: The fatigue limit of welding methods became low in the order of SMAW, FCAW, SAW.

  • PDF

원전 주배관의 응력부식 가상결함 성장에 대한 잔류응력 영향 평가 (Stress Corrosion Crack Growth Evaluation in Primary Loop of Nuclear Power Plant)

  • 양준석;박치용;윤기석;강선예;오종근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.274-277
    • /
    • 2004
  • The most important mode of subcritical crack growth is primary water stress corrosion crack, which was the reported mechanism from the root cause analysis of the crack in the bimetallic welds. Stress corrosion crack growth evaluations was carried out for several flaw shapes of both axial and circumferential flaws, using the steady-state stresses including residual stresses. This evaluation considered the possibility of additional flaws in the primary loops of nuclear power plant, even though no such flaws have been identified by Ultrasonic Test. Consequently, Results show that the predicted flaw sizes will determine acceptability for continued service and maintenance.

  • PDF

최고도이상의 청력손실을 가진 아동의 모음음형대 분석 (An Acoustic Analysis of Vowels for Severe-profound Hearing Impaired Children)

  • 허명진
    • 음성과학
    • /
    • 제14권2호
    • /
    • pp.65-71
    • /
    • 2007
  • The severe-profound hearing impaired children have various disorders in everday communication due to the lack of hearing feedback. Especially, their speech produced unstable voice, omission and distortion of articulation, pitch break, cul-de-sac voice, and so on so that they were difficult to accurately deliver an intended message. This study attempts to analyze the acoustic characteristics of 4 vowel sounds produced by 35 severe-profound hearing impaired children using CSL(Computerized Speech Lab, Model 4300b). The formant data were obtained from the spectrogram and analyzed data by 12 formant filter and auto-correlation among the formants. Results showed that the hearing impaired children's formant values came out very high. They produced the vowels at the mode of hypertension with unstable voice. In order to improve their speech, they would need some adequate auditory feedback.

  • PDF

유압 브레이커(Hydraulic breaker)의 고장분석을 통한 수명분석 연구 (A Study About Reliability Analysis of Hydraulic Breakers through Failure Mode Effect Analysis)

  • 하호진;김광섭
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권3호
    • /
    • pp.177-193
    • /
    • 2009
  • Hydraulic breakers, the attachment devices of the excavators, refer to a machine that converts back and forth motions of pistons into energies to break objects down finely. As the use of hydraulic breakers has been steadily increasing world-wide, consumers have become more interested in not just the quality of hydraulic breakers but their reliability. This study show functions and usages of several main parts on hydraulic breakers. In addition, based on the effect of action of hydraulic breakers, FMEA was performed to figure out the major causes and manifestations of malfunctioning. As above mentioned, we analyzed reliability of hydraulic breakers by models, and the data that had been used for the analyses were obtained from malfunctioning data in the field.

  • PDF

The cavitating flow simulation in cryogenic fluid around 3D objects

  • ;이창진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.264-267
    • /
    • 2010
  • This research focuses on the development of numerical code to deal with compressible two phase flow around three dimensional objects combined with cavitation model suggested by Weishyy et al. with k-e turbulent model. The cryogenic cavitation is carried out by considering the thermodynamic effect on physical properties of cryogenic fluids in physical point of view and implementing the temperature sensitivity in the energy equation of the government equations in numerical point of view, respectively. The formulation has been extensively validated for both liquid nitrogen and liquid hydrogen by simulating the experiments of Hord on hydrofoils. Then, simulations of cavitating turbopump inducers at their design flow rate are presented. Results over a broad range of Nss numbers extending from single-phase flow conditions through the critical head break down point are discussed. In particular, thermal depression effects arising from cavitation in cryogenic fluids are identified and their impact on the suction performance of the inducer quantified.

  • PDF

지하역사에서의 화재연기거동 실험 (Experiments of Smoke Behavior in an Underground Subway Station)

  • 김동현;장용준;박원희
    • 한국철도학회논문집
    • /
    • 제10권1호
    • /
    • pp.67-73
    • /
    • 2007
  • Experiments were carried out to investigate smoke movement in platform of a subway station which currently is in service in Pusan, the second largest city in Korea. The recently constructed underground station of the "bank type" (two platforms on both sides of track) which is the popular layout of platforms in Korea, is chosen in Pusan. The smoke generator and heater are used for simulating the smoke movement at the fire break in the platform located in the 2nd basement of the station. Video recordings were used to monitor smoke lowering. In this study, the movements of smoke in the underground station are investigated under various smoke-control operating modes. Three tests wire conducted according to its operating mode of the ventilation systems in the platform: no operation of any ventilation systems, smoke extraction mode in occurrence of fire (presently running mode) and full capacity of smoke extraction where all vents are activated in the platform. The results can be used for comparing with the numerical prediction results of fire subway stations.

건설업종사자의 직군별 화학물질과민증 위해성 평가에 관한 연구 (The Research about the Risk Assessment by Job Groups in Construction Worker)

  • 성기철;전정윤;박준석
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2005년도 추계학술대회 논문집
    • /
    • pp.295-300
    • /
    • 2005
  • This Study intends to find out the subjective symptom of Construction Business Worker caused by chemical material exposure, also willing to research how much they are exposed to VOCs(Volatile Organic Compounds) and under how much harmful circumstance they are working. As the results, the job group among construction business workers which is most highly dangerous degree to be taken ill of Multiple Chemical Sensitivity is Interior Worker, next following by order of Clerical Worker, Exterior Worker. According to this result, the continuous exposure in high density must be prevented by the measures for Interior Worker also to be bestowed a compulsory break during working hour for regular exposure to the open air,

  • PDF