• Title/Summary/Keyword: Break test

Search Result 554, Processing Time 0.028 seconds

A Study on the Confidence of Dry Eye Diagnosis Methods (건성안 검사 방법의 신뢰도에 대한 연구)

  • Lee, Byeong Jun;Hong, Jae Hyeon;Jung, Dai;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.15-20
    • /
    • 2008
  • Purpose: To study on the confidence of dry eye diagnosis methods which need to prescribe contact lens. Methods: Non-invasive tear film break-up time (NIBUT) and tear film break-up time (TBUT) were measured in forty healthy subjects in their 20s, and then the subjects were classified into normal eye and dry eye. The results of McMonnies questionnaire, tear prism height measurement, Hardtack test, blink rate measurement and Schirmer test were compared with the results of NIBUT and TBUT. Results: The results of NIBUT and TBUT were as follows; 20 subjects had normal eyes, 10 subjects had dry eyes in both NIBUT and TBUT, and 10 subjects showed different results. In McMonnies questionnaire, the score of normal eye group averaged 8.2 and that of dry eye group averaged 18.5, which showed statistically significant difference. Furthermore, 100% of normal eye group classified by the results of NIBUT and TBUT corresponded with the result of McMonnies questionnaire and 90% of dry eye group showed the correspondence. Tear prism height of normal eye group averaged 0.32 mm and that of dry eye group averaged 0.23 mm, which were significantly different. Hardtack test, blink rate measurement and Schirmer test without local anesthesia showed no statistically significant difference between normal eye group and dry eye group. Conclusions: On dry eye diagnosis methods, the results of McMonnies questionnaire and tear prism height measurement had close correlation with the results of NIBUT and TBUT.

  • PDF

Analyses of Overtopping Velocity using Analytical Solution(Ritter's Solution) of Dam-Break Flow (댐 붕괴흐름의 해석해(Ritter의 해)를 이용한 월파유속 분석)

  • Ryu, Yong-Uk;Lee, Jong-In;Kim, Young-Taek
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.7
    • /
    • pp.669-679
    • /
    • 2008
  • The present study examines similarity of behavior between an overtopping wave generated by a plunging wave and a dam-break flow through hydraulic model tests. The dam-break flow has been employed to estimate the overtopping effect on the basis of the dam-break flow's behavior similar to the overtopping. In this study, the overtopping velocity was measured by a modified image technique using bubble and bubble texture images called bubble image velocitmetry. From the measurements, the vertical profiles of horizontal overtopping velocity at cross-sections along the deck were presented and discussed. Maximum velocity and depth-averaged velocity at each cross-section were compared with an analytical solution solving the dam-break flow, Ritter's solution. The initial water depth of importance for the solution was determined from the tested wave condition and the overtopping measurements. The comparison shows that the solution with the initial water depth estimated using the front velocity of the overtopping wave is in good agreements with the measurements.

SBLOCA AND LOFW EXPERIMENTS IN A SCALED-DOWN IET FACILITY OF REX-10 REACTOR

  • Lee, Yeon-Gun;Park, Il-Woong;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.347-360
    • /
    • 2013
  • This paper presents an experimental investigation of the small-break loss-of-coolant accident (SBLOCA) and the loss-of-feedwater accident (LOFW) in a scaled integral test facility of REX-10. REX-10 is a small integral-type PWR in which the coolant flow is driven by natural circulation, and the RCS is pressurized by the steam-gas pressurizer. The postulated accidents of REX-10 include the system depressurization initiated by the break of a nitrogen injection line connected to the steam-gas pressurizer and the complete loss of normal feedwater flow by the malfunction of control systems. The integral effect tests on SBLOCA and LOFW are conducted at the REX-10 Test Facility (RTF), a full-height full-pressure facility with reduced power by 1/50. The SBLOCA experiment is initiated by opening a flow passage out of the pressurizer vessel, and the LOFW experiment begins with the termination of the feedwater supply into the helical-coil steam generator. The experimental results reveal that the RTF can assure sufficient cooldown capability with the simulated PRHRS flow during these DBAs. In particular, the RTF exhibits faster pressurization during the LOFW test when employing the steam-gas pressurizer than the steam pressurizer. This experimental study can provide unique data to validate the thermal-hydraulic analysis code for REX-10.

A Study on Development of EMC Filter for Power Lime in Break-box (인입선 Break-box 내의 EMC 대책용 필터 개발에 관한 연구)

  • 배대환;김동일;배재영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.2
    • /
    • pp.245-250
    • /
    • 2001
  • Since the most of malfunctions in the industrial equipment controlled by processors is occurred by the Electrical Fast Transient(EFT), the International Electrotechnical Commission(IEC) prepared the dummy signal to test the immunity level of the equipments. In this paper, we designed a new EMC fitter for power line in break-box, which consist of the feed-through capacitor and ferrite materials with high permeability, which was wound or inserted, in the second layer of the power cable in order to increase common mode inductance. We have obtained a excellent insertion loss characteristics over wide frequency band from 10 MHz up to 1.5 GHz. It is expected that the new EMC filter could be effectively used for industrial, MIL, and medical equipments to reduce a malfunctions and be suitable for IEC 61000-4-4.

  • PDF

A Study on the Application of Phased Array Ultrasonic Testing to Main Steam Line in Nuclear Power Plants (원전 주증기배관 웰더렛 용접부 위상배열초음파검사 적용연구)

  • Lee, Seung-Pyo;Kim, Jin-Hoi
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.3
    • /
    • pp.40-47
    • /
    • 2011
  • KSNPs(Korea Standard Nuclear Power Plant) have been applied the break exclusion criteria to the high energy lines passing through containment penetration area to ensure that piping failures would not cause the loss of containment isolation function, and to reduce the resulting dynamic effects. Systems with the criteria are the Main Steam system, Feed Water system, Steam Generator Blowdown system, and Chemical & Volume Control system. In accordance with FSAR(Final Safety Analysis Report), a 100% volumetric examination by augmented in-service inspection of all pipe welds appled the break exclusion criteria is required for the break exclusion application piping. However, it is difficult to fully satisfy the requirements of inspection because 12", 8" and 6" weldolet weldments of Main Steam pipe line have complex structural shapes. To resolve the difficulty on the application of conventional UT(Ultrasonic Testing) technique, realistic mock-ups and UT calibration blocks were made. Simulations of conventional UT were performed utilizing CIVA, a commercial NDE(Nondestructive Examination) simulation software. Phased array UT experiments were performed through mock-up including artificial notch type flaws. A phased array UT technique is finally developed to improve the reliability of ultrasonic test at main steam line pipe to 12", 8" and 6" branch connection weld.

Reological Studies on Cocoon Filament II. Changes of strength and elongation at breaking related to the stretching speed and swelling degree (견사의 탄성적성질에 관한 연구 II. 인장속도 및 팽윤에 따른 파괴강신도의 변화)

  • 남중희
    • Journal of Sericultural and Entomological Science
    • /
    • v.14 no.2
    • /
    • pp.105-112
    • /
    • 1972
  • The effects of the stretching speed and the swelling degree of cocoon filaments on load-elongation curve were tested by tensilon with special attachments. The values of breaking strength, elongation at break and initial tensile strength obtained from load elongation curves are summarized as follows; 1. The breaking strength of the swollen cocoon filament appeared to increase at the high stretching speed, while elongation at break decreased. 2. Load-elongation curve became crinkled at the low speed of stretching. It suggests that both slip and break of the macrofibrils may occur in swelling of cocoon bave. 3. Breaking strength appeared to considerably decrease and elongation at break not to increase in swelling test at 9$0^{\circ}C$ for 60 min. 4. The initial tensile strength was influenced by the stretching speed and swelling degree of cocoon filaments.

  • PDF

AN EXPERIMENTAL STUDY WITH SNUF AND VALIDATION OF THE MARS CODE FOR A DVI LINE BREAK LOCA IN THE APR1400

  • Lee, Keo-Hyoung;Bae, Byoung-Uhn;Kim, Yong-Soo;Yun, Byong-Jo;Chun, Ji-Han;Park, Goon-Cherl
    • Nuclear Engineering and Technology
    • /
    • v.41 no.5
    • /
    • pp.691-708
    • /
    • 2009
  • In order to analyze thermal hydraulic phenomena during a DVI (Direct Vessel Injection) line break LOCA (Loss-of-Coolant Accident) in the APR1400 (Advanced Power Reactor 1400 MWe), we performed experimental studies with the SNUF (Seoul National University Facility), a reduced-height and reduce-pressure integral test loop with a scaled down APR1400. We performed experiments dealing with eight test cases under varied tests. As a result of the experiment, the primary system pressure, the coolant temperature, and the occurrence time of the downcomer seal clearing were affected significantly by the thermal power in the core and the SI flow rate. The break area played a dominant role in the vent of the steam. For our analytical investigation, we used the MARS code for simulation of the experiments to validate the calculation capability of the code. The results of the analysis showed good and sufficient agreement with the results of the experiment. However, the analysis revealed a weak capability in predicting the bypass flow of the SI water toward the broken DVI line, and it was insufficient to simulate the streamline contraction in the broken side. We, hence, need to improve the MARS code.

Tensile Characteristics of ETFE Film According to the Specimen Type (시험편 형상에 따른 ETFE 필름재의 인장 특성)

  • Kim, Seung-Deog;Chu, Seok-Beom;Jang, Myung-Ho;Lee, Jeong-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.159-165
    • /
    • 2017
  • In this paper, uniaxial tensile tests of ETFE films with three kinds of thicknesses(100, 200, $250{\mu}m$) and two kinds of directions(machine direction & transverse direction) are performed and the tensile strength, the tensile strain at break and the Young's modulus of ETFE films are compared for two kinds of specimen types(2 & 5). It could be figured out that there are no significant difference between tensile strengths of two specimen types but the tensile strain at break and the Young's modulus of ETFE films are affected by the specimen types. And it is concluded that the uniaxial tensile test of specimen type 2 are more reliable than that of specimen type 5.

Short-circuit making and breaking test for 362kV, 63kA circuit breaker (362kV, 63kA 초고압차단기 투입차단시험)

  • Park Seung Jae;Suh Yoon Taek;Yoon Hack Dong;Kim Maeng Hyun;Koh Heui Seog
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.554-556
    • /
    • 2004
  • Testing capacity of KERI synthetic short-circuit testing facilities has been upgraded to fulfill the requirements up to 550kV 63kA, 1-break circuit breaker ratings. Specially the current capacity was increased 50kA to 63kA and the full type test of 362kV 63kA circuit breaker(1-break) was firstly completed in domestic. UP to now, domestic manufacturers have depended on the foreign testing laboratory for performance verification of newly designed products. This paper introduces the summary of the increased short-circuit testing facilities, the testing techniques and its results for the making and breaking performance of 362kV, 63kA circuit breaker which was Performed according to IEEE C37.06(1999) used in North America.

  • PDF

Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems (CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도)

  • Kang, Hoo-Won;Kim, Hee-Jin;Kim, Jang-Ju;Ko, Myung-Won
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).