• Title/Summary/Keyword: Branch-type Tree

Search Result 39, Processing Time 0.024 seconds

A Study on Prediction of Treeting Breakdown in XLPE Cable According to Method of Acoustic Emission Detection (음향방출 계측법에 따른 가교폴리에틸렌 케이블의 트리잉 파괴 예지에 관한 연구)

  • 김재환;박재준
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.4
    • /
    • pp.26-33
    • /
    • 1993
  • The acoustic emission automatic detection system is developed to observe tree deterioration phenomena. Applying an alternating voltage of 15(kVnns) toXLPE tree specimens, many pulses of small amplitude are detected when the bush type tree developes branch type and a few pulses of high amplitude prcxluced as branch type propagated to bush type tree. Therefore, it is known that pulses having small amplitude operates as a destructive factor. It is observed that the skewness of the amplitude and the number of average pulses as distribution tendency of three dimension are characteristic quantity of AE pulses. As the trajectory of skewness is farther from the origin on the S-plane, it is more likely to breakdown.

  • PDF

Dependence of needle tip Curvature of the Inception Stress and Propagation of electrical tree (침전극의 곡율반경에 따른 트리개시전계 및 트리진전 특성)

  • 박영국;김완수;이홍규;이용희;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.59-62
    • /
    • 1999
  • Inception and propagation of electrical tree and properties of Partial discharge(PD) pulses accompanying with tree as a function of needle tip radius in low density polyethylene were discussed. To study on these characteristics in different tip radius, we used specimens with needle-plane electrode system made of LDPE, observed inception and propagation of electrical tree by optical microscope with computer and investigated the characteristics of the phase resolved PD pulses accompanying with propagation of electrical tree. The PD quantities detected and analysed were PD magnitude, mean phase angle, average discharge, and the statistical characteristics of the PD pulses. As the tip radius ${\gamma}$ increases, tree inception stress E$\sub$i/ converges to constance value. This result suggests that tree inception stress E$\sub$i/ increases due to stress relaxation when the tip radius is small. Branch-type electrical tree was formed When E$\sub$i/ is 640-750[kV/mm]. bush-type electrical tree when E$\sub$i/ is 370∼400[kV/mm], branch-like electrical tree when E$\sub$i/ is 370-400[kV/mm].

  • PDF

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Tree-inspired Chair Modeling (나무 성장 시뮬레이션을 이용한 의자 모델링 기법)

  • Zhang, Qimeng;Byun, Hae Won
    • Journal of the Korea Computer Graphics Society
    • /
    • v.23 no.5
    • /
    • pp.29-38
    • /
    • 2017
  • We propose a method for tree-inspired chair modeling that can generate a tree-branch pattern in the skeleton of an arbitrary chair shape. Unlike existing methods that merge multiple-input models, the proposed method requires only one mesh as input, namely the contour mesh of the user's desired part, to model the chair with a branch pattern generated by tree-growth simulation. We propose a new method for the efficient extraction of the contour-mesh region in the tree-branch pattern. First, we extract the contour mesh based on the face area of the input mesh. We then use the front and back mesh information to generate a skeleton mesh that reconstructs the connection information. In addition, to obtain the tree-branch pattern matching the shape of the input model, we propose a three-way tree-growth simulation method that considers the tangent vector of the shape surface. The proposed method reveals a new type of furniture modeling by using an existing furniture model and simple parameter values to model tree branches shaped appropriately for the input model skeleton. Our experiments demonstrate the performance and effectiveness of the proposed method.

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.

Genetic Relationships of Lactuca spp. Revealed by RAPD, Inter-SSR, AFLP, and PCR-RFLP Analyses

  • Yang, Tae-Jin;Jang, Suk-Woo;Kim, Won-Bae
    • Journal of Crop Science and Biotechnology
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • RAPD, Inter-SSR, and AFLP markers were used to assess the genetic diversity of lettuce cultivars and the phylogenetic relationships in Lactuca spp. A total of 216 polymorphic bands from seven RAPD primers, four Inter-SSR primers, and five AFLP primer combinations were used to elucidate the genetic similarity among lettuce cultivars. Forty-four lettuce accessions were subdivided into discrete branches according to plant type: crisphead, butterhead, and stem type, with some exceptions. The leafy- and cos-type accessions were intermingled in other groups with no discrete branch indicating that these are more diverse than others. Three accessions, including the Korean cultivar 'Cheongchima', the Korean local landrace 'Jinjam', and the German cultivar 'Lolla Rossa' were classified as the most diverse accessions. Twenty bands were unique in specific cultivars. Among these, three were specific in a plant type; one in Korean leafy type, one in crisphead type, and one in cos type lettuce. In the phylogenetic analysis among Lactuca species, L. saligna, L. serriola, and L. georgica clustered in a sister branch of the L. sativa complex. Two L. virosa accessions show the highest intra-specific relationships. L. perennis outlied from all the other Lactuca species at a genetic similarity of 0.53 and clustered with two Cichorium species, C. intybus and C. endivia, with genetic similarity of 0.67. The phylogenetic tree was supported by data from polymorphism of chloroplast genome which was revealed by PCR-RFLP.

  • PDF

Electrical Pulses of Internal Partial Discharges Accompanying with Electrical Tree in LDPE (LDPE에서 발생된 전기트리에 수반된 내부 부분방전 펄스 해석)

  • Kang, S.H.;Park, Y.G.;Kwon, S.S.;Shin, T.S.;Lim, K.J.
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.216-221
    • /
    • 1999
  • The correlation between propagation of electrical tree and internal partial discharges is discussed. We use specimens with needle-plane electrode system made of LDPE(Low Density Polyethylene), observed inception and propagation of electrical tree by optical microscope and investigated the characteristics of the partial discharge (PD) pulses accompanying with propagation of electrical tree. In the specimens with needle-shaped void, the tree propagates branch type. The length of the tree has good linear relation with average discharge power of PD pulses. In the specimens without needle-shaped void, the tree grows bush type tree. The correlation between the area of the tree and the average discharge power of PD pulses has linear relation.

  • PDF

A Study on the Correlation Between the PD Pattern and the Type of Electrical Trees Propagation in the XLPE Insulation for the Underground Power Transmission

  • Lee, Jeon-Seon;Kim, Jeong-Tae;Koo, Ja-Yoon
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.12-17
    • /
    • 2001
  • In this work, the correlation between the PD Patterns and the electrical tree propagation has been investigated by use of the specimen removed from the insulation of the real 154 kV XLPE underground power cables. As a result, it could be deduced that the PD pattern regarding electrical trees depends on their type which could be classified into three different distinct groups such as branch-bush mixed. Considering the results of our investigation, if the partial discharge magnitude is only considered for the diagnosis of the cable system, it is possible to draw a wrong decision. Therefore, it is possible to propose that the time characteristics of PD pattern should be taken into account for the diagnosis of the cable system in addition to the conventional $\Phi$-q-n characteristics.