• 제목/요약/키워드: Brain ventricular system

검색결과 19건 처리시간 0.026초

Hydrocephalus: Ventricular Volume Quantification Using Three-Dimensional Brain CT Data and Semiautomatic Three-Dimensional Threshold-Based Segmentation Approach

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • 제22권3호
    • /
    • pp.435-441
    • /
    • 2021
  • Objective: To evaluate the usefulness of the ventricular volume percentage quantified using three-dimensional (3D) brain computed tomography (CT) data for interpreting serial changes in hydrocephalus. Materials and Methods: Intracranial and ventricular volumes were quantified using the semiautomatic 3D threshold-based segmentation approach for 113 brain CT examinations (age at brain CT examination ≤ 18 years) in 38 patients with hydrocephalus. Changes in ventricular volume percentage were calculated using 75 serial brain CT pairs (time interval 173.6 ± 234.9 days) and compared with the conventional assessment of changes in hydrocephalus (increased, unchanged, or decreased). A cut-off value for the diagnosis of no change in hydrocephalus was calculated using receiver operating characteristic curve analysis. The reproducibility of the volumetric measurements was assessed using the intraclass correlation coefficient on a subset of 20 brain CT examinations. Results: Mean intracranial volume, ventricular volume, and ventricular volume percentage were 1284.6 ± 297.1 cm3, 249.0 ± 150.8 cm3, and 19.9 ± 12.8%, respectively. The volumetric measurements were highly reproducible (intraclass correlation coefficient = 1.0). Serial changes (0.8 ± 0.6%) in ventricular volume percentage in the unchanged group (n = 28) were significantly smaller than those in the increased and decreased groups (6.8 ± 4.3% and 5.6 ± 4.2%, respectively; p = 0.001 and p < 0.001, respectively; n = 11 and n = 36, respectively). The ventricular volume percentage was an excellent parameter for evaluating the degree of hydrocephalus (area under the receiver operating characteristic curve = 0.975; 95% confidence interval, 0.948-1.000; p < 0.001). With a cut-off value of 2.4%, the diagnosis of unchanged hydrocephalus could be made with 83.0% sensitivity and 100.0% specificity. Conclusion: The ventricular volume percentage quantified using 3D brain CT data is useful for interpreting serial changes in hydrocephalus.

Delayed Cerebral Abscess as a Shunt Complication and Endoscopic Removal of the Ventricular Catheter and Abscess

  • Shin, Dong-Seong;Hwang, Sun-Chul;Kim, Bum-Tae;Shin, Won-Han
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권6호
    • /
    • pp.300-303
    • /
    • 2008
  • Shunt infections are a common complication of ventriculoperitoneal (VP) shunts, but the formation of a brain abscess related to a shunt system is very rare. A 44-year-old woman had a VP shunt inserted for hydrocephalus secondary to a subarachnoid hemorrhage. She suffered an episode of meningitis and sepsis 8 months after the shunt operation. After recovering from the meningitis, she complained of a loss of cognitive function. An enhancing mass was found in the frontal lobe, around the frontal horn of the lateral ventricle, and the ventricular catheter was embedded inside the mass. The ventricular catheter and cerebral abscess were removed using neuroendoscopy. We present an interesting case of a shunt-related brain abscess which illustrates the usefulness of neuroendoscopy.

인공신경망을 이용한 좌심실보조장치의 제어 시뮬레이션 (Control Simulation of Left Ventricular Assist Device using Artificial Neural Network)

  • 김상현;정성택;김훈모
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권1호
    • /
    • pp.39-46
    • /
    • 1998
  • 본 연구에서 복잡한 비선형적 특성을 갖는 공압식 좌심실보조장치의 모델링과 제어에 인공신경망을 제안하였다. 일반적으로 좌심실보조장치는 비선형이 보상되어야 하는데 인공신경망은 학습능력에 의해 비선형 동적 시스템의 제어에 적용될 수 있다. 인공신경망 모델링을 통해 좌심실 보조장치의 동적 모델을 모델링하고 이를 기반으로 하여 인공신경망 제어기가 설계되었다. 제안된 알고리즘을 이용한 좌심실보조장치의 모델링과 제어성능 및 유효성은 컴퓨터 시뮬레이션에 의해 증명되었다.

  • PDF

시상부 뇌농양의 뇌실내로의 파열 - 증례보고 - (Intraventricular Rupture of a Thalamic Abscess - A Case Report -)

  • 정득채;장석정;안태형
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권9호
    • /
    • pp.1140-1143
    • /
    • 2001
  • The mortality of patients with brain abscess has decreased significaltly. This has been attributed to improved diagnostic imaging, the evolution of neurosurgical techniques and understanding of intracranial pressure pathophysiology, greater critical care understanding, and newer antibiotics. However, the mortality associated with intraventricular rupture of brain abscess remained consistently high at or above 80% once identified. A case of intraventicular rupture of thalamic abscess with good quality of survival is presented based on aggressive 4-component therapeutic plan used. The four components are 1) extraventricular drainage for 6 weeks, 2) lavage of the ventricular system using closed irrigation system, 3) intravenous antibiotics, 4) intraventricular gentamicin and vancomycin, twice and once daily, respectively.

  • PDF

Migration of Sparganosis from the Brain to the Cervical Spinal Cord

  • Jang, Se-Youn;Kim, Choong-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.170-172
    • /
    • 2012
  • Central nervous system (CNS) sparganosis is a rare parasitic infestation caused by ingestion of the raw or inadequately cooked snakes or frogs. Sparganum is well known for its ability of migrating though the tissue, therefore, it can cause various neurological symptoms if it involves neurological systems. A 51-year-old male patient visited our department of neurosurgery complaining of the motor weakness and radiating pain on both upper extremities over 4 months. He had a history of ingesting raw snakes untill his late twenties. The magnetic resonance (MR) images of. cervical spine revealed an intramedullary ill-defined enhancing lesion with the aggregated cysts in the upper cervical spinal cord. Under presumptive diagnosis of sparganosis, we took brain MR image. The brain MR images revealed the signal change in right fronto-temporallobe suggesting the trajectory of parasitic migration via ventricular systems. He underwent a midline myelotomy and granuloma removal followed by the posterior laminoplasty. Pathologic findings showed inflammatory changes and necrosis with keratinized tissue suggesting the CNS sparganosis. We report an uncommon case of CNS sparganosis migrated from the brain to the spinal cord with literature review.

Algorithm of Copulsation Estimation for Counterpulsation using Pressure of VAD Outlet Cannula

  • Kang Jung-Soo;Lee Jung-Joo;Jung Min-Woo;Park Yong-Doo;Sun Kyung
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권2호
    • /
    • pp.78-82
    • /
    • 2006
  • The ventricular assist device(VAD) helps to reduce the overload against the patient's native heart(NH). The pulsatile VAD pumps out the ventricular blood to the aorta with pulsatile flow. If the VAD pulsates simultaneously with the NH, the ventricle of the NH could confronts abnormally elevated aortic pressure, and this could deteriorate the ventricle rather than assist to recover it. Thus counterpulsation algorithms to avoid copulsation have been adopted by many VADs, but these methods utilize electrocardiography or arterial pressure signals, which may have difficulties to acquire consistently for a long period. In this study, the copulsation estimation algorithm for the counterpulsation is developed using the VAD outlet pressure signal. The VAD outlet pressure signal is good to maintain for a long time and the sensor part could be integrated to the VAD as a built-in module. From the VAD outlet pressure signal and its pump rate information calculated with Fast Fourier Transform, pulse peaks by the VAD and the NH were extracted and the next copulsation time at which the VAD and the NH would pulsate simultaneously was estimated. This estimation algorithm was implemented by using PC MATLAB software and tested for various pump rate conditions with mock circulation system. For each condition, the copulsation time was estimated successfully. Consequently, the results showed the possibility to use the outlet cannula pressure signal in the copulsation estimation.

Retrospective Analysis of Cerebrospinal Fluid Profiles in 228 Patients with Leptomeningeal Carcinomatosis : Differences According to the Sampling Site, Symptoms, and Systemic Factors

  • Shim, Youngbo;Gwak, Ho-Shin;Kim, Sohee;Joo, Jungnam;Shin, Sang-Hoon;Yoo, Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권6호
    • /
    • pp.570-576
    • /
    • 2016
  • Objective : Elevated cell counts and protein levels in cerebrospinal fluid (CSF) result from disease activity in patients with leptomeningeal carcinomatosis (LMC). Previous studies evaluated the use of CSF profiles to monitor a treatment response or predict prognosis. CSF profiles vary, however, according to the sampling site and the patient's systemic condition. We compared lumbar and ventricular CSF profiles collected before intraventricular chemotherapy for LMC and evaluated the association of these profiles with patients' systemic factors and LMC disease activity. Methods : CSF profiles were retrospectively collected from 228 patients who underwent Ommaya reservoir insertion for intraventricular chemotherapy after a diagnosis of LMC. Lumbar samples taken via lumbar puncture were used for the diagnosis, and ventricular samples were obtained later at the time of Ommaya reservoir insertion. LMC disease activity was defined as the presence of LMC-related symptoms such as increased intracranial pressure, hydrocephalus, cranial neuropathy, and cauda equina syndrome. Results : Cell counts (median : 8 vs. 1 cells/mL) and protein levels (median : 68 vs. 17 mg/dL) significantly higher in lumbar CSF than in ventricular CSF (p<0.001). Among the evaluated systemic factors, concomitant brain metastasis and previous radiation were significantly correlated with higher protein levels in the lumbar CSF (p=0.01 and <0.001, respectively). Among the LMC disease activity, patients presenting with hydrocephalus or cauda equina syndrome showed higher lumbar CSF protein level compared with that in patients without those symptoms (p=0.049 and p<0.001, respectively). The lumbar CSF cell count was significantly lower in patients with cranial neuropathy (p=0.046). The ventricular CSF cell counts and protein levels showed no correlation with LMC symptoms. Carcinoembryonic antigen (CEA), which was measured from ventricular CSF after the diagnosis in 109 patients, showed a significant association with the presence of hydrocephalus (p=0.01). Conclusion : The protein level in lumbar CSF indicated the localized disease activity of hydrocephalus and cauda equina syndrome. In the ventricular CSF, only the CEA level reflected the presence of hydrocephalus. We suggest using more specific biomarkers for the evaluation of ventricular CSF to monitor disease activity and treatment response.

A Study of Electromagnetic Actuator for Electro-pneumatic Driven Ventricular Assist Device

  • Jung Min Woo;Hwang Chang Mo;Jeong Gi Seok;Kang Jung Soo;Ahn Chi Bum;Kim Kyung Hyun;Lee Jung Joo;Park Yong Doo;Sun Kyung
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권6호
    • /
    • pp.393-398
    • /
    • 2005
  • An electromechanical type is the most useful mechanism in the various pumping mechanisms. It, however, requires a movement converting system including a ball screw, a helical cam, or a solenoid-beam spring, which makes the device complex and may lessen reliability. Thus, the authors have hypothesized that an electromagnetic actuator mechanism can eliminate the movement converting system and that thereby enhance the mechanical reliability and operative simplicity of an electro­pneumatic pump. The purpose of this study was to show a novel application of electromagnetic actuator mechanism in pulsatile pump and to provide preliminary data for further evaluations. The electromagnetic actuator consists of stators with a single winding excitation coil and movers with a high energy density neodymium-iron-boron permanent magnet. A 0.5mm diameter wire was used for the excitation coil, and 1000 turns were wound onto the stators core with parallel. A prototype of extracorporeal electro-pneumatic pump was constructed, and the pump performance tests were performed using a mock system to evaluate the efficiency of the electromagnetic actuator mechanism. When forward and backward electric currents were supplied to the excitation coil, the mover effectively moved back and forth. The nominal stroke length of the actuator was 10mm. The actuator dimension was 120mm in diameter and 65mm in height with a mass of 1.4kg. The prototype pump unit was 150mm in diameter, 150mm in thickness and 4.5kg in weight. The maximum force output was 70N at input current of 4.5A and the maximum pump rate was 150 beats per minute. The maximum output was 2.0 L/minute at a rate of 80bpm when the afterload was 100mmHg. The electromagnetic actuator mechanism was successfully applied to construct the prototype of extracorporeal electro­pneumatic pump. The authors provide the above results as a preliminary data for further studies.

Biases in the Assessment of Left Ventricular Function by Compressed Sensing Cardiovascular Cine MRI

  • Yoon, Jong-Hyun;Kim, Pan-ki;Yang, Young-Joong;Park, Jinho;Choi, Byoung Wook;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.114-124
    • /
    • 2019
  • Purpose: We investigate biases in the assessments of left ventricular function (LVF), by compressed sensing (CS)-cine magnetic resonance imaging (MRI). Materials and Methods: Cardiovascular cine images with short axis view, were obtained for 8 volunteers without CS. LVFs were assessed with subsampled data, with compression factors (CF) of 2, 3, 4, and 8. A semi-automatic segmentation program was used, for the assessment. The assessments by 3 CS methods (ITSC, FOCUSS, and view sharing (VS)), were compared to those without CS. Bland-Altman analysis and paired t-test were used, for comparison. In addition, real-time CS-cine imaging was also performed, with CF of 2, 3, 4, and 8 for the same volunteers. Assessments of LVF were similarly made, for CS data. A fixed compensation technique is suggested, to reduce the bias. Results: The assessment of LVF by CS-cine, includes bias and random noise. Bias appeared much larger than random noise. Median of end-diastolic volume (EDV) with CS-cine (ITSC or FOCUSS) appeared -1.4% to -7.1% smaller, compared to that of standard cine, depending on CF from (2 to 8). End-systolic volume (ESV) appeared +1.6% to +14.3% larger, stroke volume (SV), -2.4% to -16.4% smaller, and ejection fraction (EF), -1.1% to -9.2% smaller, with P < 0.05. Bias was reduced from -5.6% to -1.8% for EF, by compensation applied to real-time CS-cine (CF = 8). Conclusion: Loss of temporal resolution by adopting missing data from nearby cardiac frames, causes an underestimation for EDV, and an overestimation for ESV, resulting in underestimations for SV and EF. The bias is not random. Thus it should be removed or reduced for better diagnosis. A fixed compensation is suggested, to reduce bias in the assessment of LVF.