• Title/Summary/Keyword: Brain PET

Search Result 194, Processing Time 0.023 seconds

Quantification of Brain Images Using Korean Standard Templates and Structural and Cytoarchitectonic Probabilistic Maps (한국인 뇌 표준판과 해부학적 및 세포구축학적 확률뇌지도를 이용한 뇌영상 정량화)

  • Lee, Jae-Sung;Lee, Dong-Soo;Kim, Yu-Kyeong;Kim, Jin-Su;Lee, Jong-Min;Koo, Bang-Bon;Kim, Jae-Jin;Kwon, Jun-Soo;Yoo, Tae-Woo;Chang, Ki-Hyun;Kim, Sun-I.;Kang, Hye-Jin;Kang, Eun-Joo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.241-252
    • /
    • 2004
  • Purpose: Population based structural and functional maps of the brain provide effective tools for the analysis and interpretation of complex and individually variable brain data. Brain MRI and PET standard templates and statistical probabilistic maps based on image data of Korean normal volunteers have been developed and probabilistic maps based on cytoarchitectonic data have been introduced. A quantification method using these data was developed for the objective assessment of regional intensity in the brain images. Materials and Methods: Age, gender and ethnic specific anatomical and functional brain templates based on MR and PET images of Korean normal volunteers were developed. Korean structural probabilistic maps for 89 brain regions and cytoarchitectonic probabilistic maps for 13 Brodmann areas were transformed onto the standard templates. Brain FDG PET and SPGR MR images of normal volunteers were spatially normalized onto the template of each modality and gender. Regional uptake of radiotracers in PET and gray matter concentration in MR images were then quantified by averaging (or summing) regional intensities weighted using the probabilistic maps of brain regions. Regionally specific effects of aging on glucose metabolism in cingulate cortex were also examined. Results: Quantification program could generate quantification results for single spatially normalized images per 20 seconds. Glucose metabolism change in cingulate gyrus was regionally specific: ratios of glucose metabolism in the rostral anterior cingulate vs. posterior cingulate and the caudal anterior cingulate vs. posterior cingulate were significantly decreased as the age increased. 'Rostral anterior'/'posterior' was decreased by 3.1% per decade of age ($P<10^{-11}$, r=0.81) and 'caudal anterior'/'posterior' was decreased by 1.7% ($P<10^{-8}$, r=0.72). Conclusion: Ethnic specific standard templates and probabilistic maps and quantification program developed in this study will be useful for the analysis of brain image of Korean people since the difference in shape of the hemispheres and the sulcal pattern of brain relative to age, gender, races, and diseases cannot be fully overcome by the nonlinear spatial normalization techniques.

Synthesis and In vivo Evaluation of 5-Methoxy-2-(phenylethynyl)quinoline (MPEQ) and [11C]MPEQ Targeting Metabotropic Glutamate Receptor 5 (mGluR5)

  • Kim, Ji Young;Son, Myung-Hee;Choi, Kihang;Baek, Du-Jong;Ko, Min Kyung;Lim, Eun Jeong;Pae, Ae Nim;Keum, Gyochang;Lee, Jae Kyun;Cho, Yong Seo;Choo, Hyunah;Lee, Youn Woo;Moon, Byung Seok;Lee, Byung Cheol;Lee, Ho-Young;Min, Sun-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.8
    • /
    • pp.2304-2310
    • /
    • 2014
  • The synthesis and in vivo evaluation of 5-methoxy-2-(phenylethynyl)quinoline (MPEQ) 3 as a potential mGluR5 selective radioligand is described. We have identified MPEQ 3 exhibiting the analgesic effect in the neuropathic pain animal model. The effect of mGluR5 on neuronal activity in rat brain was evaluated through FDG/PET imaging in the presence of MPEQ 3. In addition, the PET study of [$^{11}C$]MPEQ 3 proved that accumulation of [$^{11}C$]MPEQ 3 in rat brain was correlated to the localization of the mGluR5.

USEFULNESS OF $^{18}F$-FDG PET/CT IN THE EVALUATION OF CERVICAL LYMPH NODE METASTASIS IN PATIENTS WITH ORAL CANCER (구강암 환자에서 $^{18}F$ FDG-PET/CT의 경부 림프절 전이 평가 유용성)

  • Yu, Min-Gi;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.

Co-registration of Human Brain MR and PET Images using the AC-PC Line

  • Paik, Chul-Hwa;Yu, Hyun-Sun;Kim, Won-Ky
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.155-156
    • /
    • 1996
  • The intercommissural(AC-PC) line is automatically detected for HR and PET images. With the detected AC-PC lines from MR and PET images, fully non-iterative automatic co- registration is accomplished. It provides a new automated method for image co-registration.

  • PDF

A Study on the PET/CT Fusion Imaging (PET/CT 결합영상진단 검사에 관한 연구)

  • Kim, Jong Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.193-198
    • /
    • 2004
  • PET/CT combines the functional information from a positron emission tomography (PET) exam with the anatomical information from a computed tomography (CT) exam into one single exam. A CT scan uses a combination of x-rays and computers to give the radiologist a non-invasive way to see inside your body. One advantage of CT is its ability to rapidly acquire two-dimensional pictures of your anatomy. Using a computer these 2-D images can be presented in 3-D for in-depth clinical evaluation. A PET scan detects changes in the cellular function - how your cells are utilizing nutrients like sugar and oxygen. Since these functional changes take place before physical changes occur, PET can provide information that enables your physician to make an early diagnosis. The PET exam pinpoints metabolic activity in cells and the CT exam provides an anatomical reference. When these two scans are fused together, your physician can view metabolic changes in the proper anatomical context of your body. PET/CT offers significant advantages including more accurate localization of functional abnormalities, and the distinction of pathological from normal physiological uptake, and improvements in monitoring treatment. A PET/CT scan allows physicians to measure the body's abnormal molecular cell activity to detect cancer (such as breast cancer, lung cancer, colorectal cancer, lymphoma, melanoma and other skin cancers), brain disorders (such as Alzheimer's disease, Parkinson's disease, and epilepsy), and heart disease (such as coronary artery disease).

  • PDF

Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF

Methodological Review on Functional Neuroimaging Using Positron Emission Tomography (뇌기능 양전자방출단층촬영영상 분석 기법의 방법론적 고찰)

  • Park, Hae-Jeong
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.2
    • /
    • pp.71-77
    • /
    • 2007
  • Advance of neuroimaging technique has greatly influenced recent brain research field. Among various neuroimaging modalities, positron emission tomography has played a key role in molecular neuroimaging though functional MRI has taken over its role in the cognitive neuroscience. As the analysis technique for PET data is more sophisticated, the complexity of the method is more increasing. Despite the wide usage of the neuroimaging techniques, the assumption and limitation of procedures have not often been dealt with for the clinician and researchers, which might be critical for reliability and interpretation of the results. In the current paper, steps of voxel-based statistical analysis of PET including preprocessing, intensity normalization, spatial normalization, and partial volume correction will be revisited in terms of the principles and limitations. Additionally, new image analysis techniques such as surface-based PET analysis, correlational analysis and multimodal imaging by combining PET and DTI, PET and TMS or EEG will also be discussed.

Synthesis and Small Animal Brain PET Study of a Serotonin Receptor Radiotracer, 18F-Mefway (세로토닌 5-HT1A수용체 방사성 추적자 18F-Mefway의 합성과 소동물 뇌 PET 연구)

  • Ahn, Sung-Min;Hong, Tae-Kee;Ryu, Young-Hoon;Choi, Jae-Yong;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.262-270
    • /
    • 2009
  • $^{18}F$-mefway has been developed as radioligand for serotonin receptor 5-$HT_{1A}$. The object of this study was to obtain the mefway precursor with the higher yield than previous method and to identify whether $^{18}F$-mefway can bind to 5-$HT_{1A}$ or not. from microPET imaging of small animal brain. Precursor was prepared by a modification of the reported procedure then [$^{18}F$] labeling was performed by adding $^{18}F$ ion at $130^{\circ}C$ in the hot cell for 30min. After purification of reaction mixture using alumina Sep-pak and HPLC, microPET images of small animal brain were determined. The chemical yield of precursor was increased from 9% to 34% using oxalyl chloride and LAH/diethylether. We synthesized a precursor which was successfully labeled with no-carrier-added $^{18}F$-by new synthetic route. This research suggest that $^{18}F$-mefway will be used a radiopharmaceutical for evaluation of central nerve system disorder as imaging a gent for 5-$HT_{1A}$ receptor.

Clinical Application of $^{18}F-FDG$ PET in Parkinson's Disease (파킨슨병에서 $^{18}F-FDG$ PET의 임상이용)

  • Lee, Won-Hyoung;Chung, Yong-An
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.177-180
    • /
    • 2008
  • Parkinson's disease is the second most common neurodegenerative disorder. It is slowly progressive disease that affects a small area of cells in the mid brain known as the substantia nigra. Gradual degeneration of these cells causes a reduction in a vital chemical known as dopamine. In the diagnosis of Parkinson's disease, it has difficulty in biopsy and limits in radiologic modalities. $^{18}F-FDG$ PET shows various findings from normal to diffuse decrement of FDG uptake. $^{18}F-FDG$ PET is expected to be a evaluation tool in the treatment of Parkinson's disease.