Objective: The coefficients of friction (COFs) of aesthetic ceramic and stainless steel brackets used in conjunction with stainless steel archwires were investigated using a modified linear tribometer and special computer software, and the effects of the bracket slot size (0.018 inches [in] or 0.022 in) and materials (ceramic or metal) on the COF were determined. Methods: Four types of ceramic (one with a stainless steel slot) and one conventional stainless steel bracket were tested with two types of archwire sizes: a $0.017{\times}0.025$-in wire in the 0.018-in slots and a $0.019{\times}0.025$-in wire in the 0.022-in slot brackets. For pairwise comparisons between the 0.018-in and 0.022-in slot sizes in the same bracket, an independent sample t-test was used. One-way and two-way analysis of variance (ANOVA) and Tukey's post-hoc test at the 95% confidence level (${\alpha}$ = 0.05) were also used for statistical analyses. Results: There were significant differences between the 0.022-in and 0.018-in slot sizes for the same brand of bracket. ANOVA also showed that both slot size and bracket slot material had significant effects on COF values (p < 0.001). The ceramic bracket with a 0.022-in stainless steel slot showed the lowest mean COF (${\mu}$ = 0.18), followed by the conventional stainless steel bracket with a 0.022-in slot (${\mu}$ = 0.21). The monocrystalline alumina ceramic bracket with a 0.018-in slot had the highest COF (${\mu}$ = 0.85). Conclusions: Brackets with stainless steel slots exhibit lower COFs than ceramic slot brackets. All brackets show lower COFs as the slot size increases.
Park, Jae-Sung;Song, In-Tae;Bae, Jae-Hee;Gil, Soo-Min;Kang, Kyung-Hwa
대한치과교정학회지
/
제50권6호
/
pp.401-406
/
2020
Objective: To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets. Methods: The following four MIM bracket series with 0.022-inch (in) slots were selected for investigation: Di MIM mini Twin (Ortho Organizers), Mini Diamond Roth (Ormco), Gemini MBT (3M Unitek), and Formula R Roth (Tomy). The following four CNC bracket series with 0.022-in slots were selected for investigation: Econoline MBT (Adenta), Legend mini MBT (GC Orthodontics), Crown mini MBT (Adenta), and Evolve MBT (DB Orthodontics). The slot dimensions were measured using an optical microscope (XTCam-D310M; Mitutoyo) with a resolution of 1 ㎛. The results were statistically analyzed using one-way analysis of variance and the Tukey post-hoc test with a significance level of 0.05. Results: The results indicated that all the investigated slot sizes were oversized with respect to the manufacturers' specifications (0.022 in). Among the eight bracket series, the Di MIM bracket (MIM) was the most oversized by 10.4%, whereas the Evolve bracket (CNC) was the least oversized by 2.6%. The slots in seven of the bracket series had divergent walls instead of parallel ones. The Evolve bracket alone had parallel slot walls. Conclusions: Regardless of the manufacturing method, all the slot sizes of the brackets investigated in this study were significantly oversized; most of the slot walls were nonparallel, except for those of the Evolve bracket. This study could not establish that the CNC method was more accurate than the MIM method in manufacturing bracket slots.
Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
대한치과교정학회지
/
제47권3호
/
pp.158-166
/
2017
Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.
The purpose of this study was to measure and compare tensile and shear strength for 4 types of new direct-bonding brackets and same brackets after recycling and to evaluate the change of bracket slot width after recycling. Four types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile and shear strength was measured by Universal Testing Machine. The brackets were recycled by chemical process and the tensile and shear test was repeated. To evaluate the change of the bracket slot width, slot width was measured by the Topcon Universal Measuring Microscope before and after recycling. Following results were obtained: 1. There was no satistically significant difference between the tensile and shear strength of recycled brackets and those of new brackets. 2. In both new and recycled brackets, the tensile and shear strength of perforated base bracket was lower than those of photoetched, foilmesh and contou-lok mesh base brackets. (P<0.01) 3. There was no statistically significant difference in bonding strengths of control group bonded only once and two times. 4. There was no statistically significant difference in the change of the bracket slow width after recycling process. 5. Of the failure, the combination type (58%) in the tensile strength and the tooth adhesive interface (65%) in the shear strength was the most common type.
This study was undertaken to determine the adequate bracket slot torque degrees in Korean The subjects were consisted of plaster casts of 30 male and 30 female They had acceptable profile, normal occlusion, no loss of tooth and no experience of dental treatment Labiolingual or buccolingual inclinations of individual tooth were estimated as +, - degrees on the fixed model by use of dental surveyor, contact angle gauge and measuring grid The following conclusions were obtained 1 Adequate degrees of bracket slot torque in Korean were obtained 2 The degrees of labiolingual or buccolingual inclination of every tooth were very variable according to the individuals 3 Almost constant torque degrees were observed on the maxillary buccal segments 4 Progressive increase in minus torque degrees were observed from the mandibular canines to the 2nd molars.
Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.
The purpose of this study was to measure and compare tensile strength for 3 types of new direct-bond brackets and the same brackets after recycling and to evaluate recycled brackets to determine the extent of physical alteration after recycling. Three types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile strength was measured by Universal Testing Machine. The brackets were recycled by thermal process and the tensile test was repeated. To determine the extent of physical alteration after recycling, the slot width and the hardness of metal brackets were measured and to analyze the microstructure of the brackets, photographs of the bracket microstructure were taken. Following results were obtained: 1. The tensile strength of recycled brackets was lower than that of new brackets, but there was no statistically significant difference. (p>0.05) 2. In the new and recycled brackets, the tensile strength of mini-mesh base bracket was statistically higher than that of conturlok base bracket, $(p\leq0.05)$ but there was no statistically significant difference between production of other companies. (p>0.05) 3. The slot width of metal bracket was enlarged from 0.459mm to 0.469mm as a result of the recycling process. (p>0.005) 4. As temperature was increased in thermal treatment, the grains of bracket metal gradually became coarser and the hardness was decreased.
본연구는 유한요소 분석법의 사용으로 세가지 형태의 브라켓에 tipping과 torquing force를 부여하여 응력분포를 알아보고 또한 스테인레스 스틸과 세라믹의 재질을 임의 설정하여 응력 분포를 알아보아 생 역학적으로 우수한 브라켓을 디자인 하는 데 기초가 되기위해 수행되었다. 선정된 세가지 브라켓은 A:Transcend(Unitek) B:Signature(RMO) C:PAW(Plane Arch Wire appliance) 이었다. 철선은 0.0175x0.025 스테인레스 스틸과 C형은 새롭게 고안된 마름모꼴 철선이 이용되었다. tipping force는 4.27N을 브라켓의 wire slot의 gingival wall의 mesial surface와 대각선으로 대칭되는 면에 각각의 node에 분력의 형태로 작용시켰다. torquing force는 couple force의 형태로 32.858N을 19.7도 회전하였고 bracket C형은 동량의 힘을 11.3도 회전하여 X와 Y의 방향으로 분력의 형태로 나누어 해석하였고 von Mises stress(최대상당응력)가 각 브라켓에서 기록되었다. 이에 다음과 같은 결론을 얻었다. 첫째, 유한요소 해석을 통해 브라켓과 wire slot을 실제로 제작하지 않고도 각각의 재료에 따른 응력분포를 예측할 수 있었다. 둘째, 응력의 집중부위는 Tipping시 브라켓 A, B, C모두 유사하게 나타났는데 브라켓 wire slot의 gingival wall과 mesial surface가 만나는 부위와 wire slot의 incisal wall과 distal surface가 만나는 부위였다. Torquing시 wire slot의 길이 방향을 따라 넓게 분포되었고 gingival wall과 협면으로 이행되는 모서리 그리고 incisal wall내면에 집중되었다. 셋째, 브라켓에 작용하는 응력은 Tipping에 의한 것보다는 Torquing에 의한 영향이 더 큼을 알수 있었으며 Torquing force를 기준으로 브라켓을 설계하는 것이 바람직한 것으로 판단되었다. 넷째, 브라켓의 형상과 함께 재료의 변화가 응력감소에 영향을 미치는 것으로 사료되므로 브라켓 제작시 한가지 재료보다 응력이 많이 받는 부위는 다른 재료를 사용하여 응력의 분포를 줄일수도 있음을 알수있었다. 다섯째, 사용하기에 용이하고 운용이 효율적일 것으로 판단되는 브라켓C형(PAW브라켓)은 응력집중현상이 다른 두 브라켓보다 크게 나타났으므로 이의 제작시 기계적 성질이 우수한 재료를 사용해야 할 것으로 사료되었다.
성인 교정 환자가 증가됨에 따라 교정장치의 심미성이 요구되고 있다. 교정 장치의 심미적 증진을 위해 개발된 브라켓들로는 세라믹, 콤포지트 레진 브라켓, 타이타늄 브라켓등이 소개되고 있다. 콤포지트 레진 브라켓은 우수한 색상 및 투과성이 장점이나 높은 마찰력과 낮은 취성의 단점을 갖고 있다. 이러한 단점을 보완하기 위하여 최근 개발된 세라믹 또는 레진 브라켓(metal reinforced bracket)은 마찰력을 감소시키고 강도를 증가시키기 위하여 브라켓의 슬롯에 메탈을 삽입하고 있다. 그러나 지금까지 이러한 metal reinforced resin bracket(이후 MRRB)의 물성에 관한 연구가 미진하였다. 특히 이러한 브라켓과 교정용 철선의 마찰력에 관한 연구가 미흡하기에 본 연구를 시행하였다. 본 연구는 4종의 교정용 철사(.016 S-S, .0l6X.022 S-S, .016 $TMA^{\circledR}$, .0l7X.025 $TMA^{\circledR}$)와 5종의 브라켓을 사용하였다. 사용된 브라켓들로는 메탈 1종(Ormco.Co., U.S.A)자 세라믹 1종($Crystalline^{\circledR}$), 콤포지트 레진 1종(Clear Medium $Siamase^{\circledR}$), 메탈 슬롯이 삽입된 콤포지트 레진2종($Plastic^{\circledR},\;Spirit^{\circledR}$)의 마찰력을 서로 비교하여 다음과 같은 결과를 얻었다. 1. ceramic bracket과 resin bracket은 metal reinforced resin bracket과 metal bracket보다 마찰력이 유의성 있게 크게 나타났다. 2. metal reinforced resin bracket의 slot내 metal의 삽입형태에 따른 마찰력의 크기는 유의차가 없었다. 3. metal reinforced resin bracket과 metal bracket사이의 마찰력의 크기는 유의차가 없었다. 4.. 교정용 철선과 각 브라켓 비교에서 TMA, Stainless steel 순으로 마찰력이 적게 나타났다.
고정성 장치를 이용한 교정 치료는 심미적 개선이 주목적 중 하나이나, 금속재 브라켓은 치료기간 동안 비심미적으로 보이는 단점이 있다. 이러한 이유로 치아색과 유사한 심미적 브라켓이 선호되었으나 호선과의 마찰저항이 금속재 브라켓보다 큰 것으로 알려져 있다. 본 연구는 최근 개발된 심미적 브라켓의 일종인 인산칼슘재 브라켓의 마찰저항을 측정하고 기존 금속재 브라켓과 금속슬롯 삽입형 도재 브라켓과의 마찰저항의 차이를 구명(究明)해 보고자 하였다. 실험군으로서 인산칼슘 재질의 Hyaline II (Tomy, Tokyo, Japan) 브라켓을, 대조군으로서 metal slot이 삽입된 도자기 재질인 Clarity (3M Unitek, Monrovia, CA, USA) 브라켓과 스테인레스 스틸 금속재 브라켓인 Kosaka (Tomy, Tokyo, Japan) 브라켓을 사용하고, $0.019\;{\times}\;0.025$ 인치 스테인레스 스틸 강선 (3M Unitek, Monrovia, CA, USA)을 이용하며 결찰재는 합성고무링 (Ormco, Glendora, CA, USA)을 사용하였다. 치아의 생리학적 환경을 재현하기 위해 모의 생물학적 모형을 고안하였으며 이에 강선을 삽입하여 load cell (Push & pull gauge, RX-2 AIKOH, Osaka, Japan)로 분당 5 mm로 견인하며 만능시험기(Instron4467, Instron, Norwood, MA, USA)로 마찰저항을 측정하였다. 실험결과, 실험군인 인산칼슘 재질 브라켓의 마찰저항은 대조군인 금속슬롯 삽입형 도재 브라켓 보다 작고 (p < 0.01) 금속재 브라켓의 마찰저항보다 크게 나타나 (p < 0.05), 인산칼슘재 브라켓은 심미적 측면에서 금속재 브라켓을, 효율적 측면에서 금속슬롯 삽입형 도재 브라켓을 대체하여 사용 가능함을 시사하였다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.