• Title/Summary/Keyword: Bracing

Search Result 364, Processing Time 0.021 seconds

Equations for Calculating Lateral-Torsional Buckling Capacity of H-Beam with Continuous Lateral Top-Flange Bracing (상부플랜지 연속 횡지지에 따른 초간편 H형강의 횡-비틀림 좌굴강도식 비교에 관한 연구)

  • Park, Jong-Sup;Lee, Son-Ho;Yoon, Ki-Young;Park, Jeong-Ung;Kim, Snag-Seup
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.437-440
    • /
    • 2007
  • Design equations for calculating the lateral-torsional buckling moment resistances of I-section beams with continuous lateral top-flange bracing subjected to several loading conditions are investigated based on elastic finite-element analyses. The equations presented in this study are compared with current moment gradient modifiers presented by other researchers and specifications. The equation suggested in the SSRC Guides(1998) has a good agreement with the results of finite-element analyses. The moment gradient correction factors proposed in the SSRC Guides(1998) should be easily used to calculate the lateral-torsional buckling moment resistance of I-beams with continuous lateral top-flange bracing.

  • PDF

Dynamic Modeling and Model Reduction for a Large Marine Engine

  • Kim, Chae-Sil;Jung, Jong-Ha;Park, Hyung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.520-525
    • /
    • 2003
  • This article provides a dynamic modeling methodology of engines to be accurate with a small number of degrees of freedom for an active vibration control using a top bracing. First. a finite element (FE) model for the engine structure is constructed so that the size of model is as small as possible where the dynamic characteristics of engine are ensured. Second. a technique is studied to obtain the exact mass and stiffness matrices of the FE model. The size of matrices from the FE model is still too large to apply. Finally, a model reduction is. therefore. conducted to make an appropriate dynamic model for designing and simulating a top bracing. In this article, a dynamic model of a large 9 cylinder engine is constructed and reviewed by comparing its natural frequencies and steady state reponses with those of experimental data provided by manufacturer.

Response Characteristics of a Nonlinear MDOF Structure with Friction Dampers (마찰형 감쇠기가 설치된 다자유도 비선형 건물의 응답특성)

  • Lee, Sung-Kyung;Park, Ji-Hun;Moon, Byoung-Wook;Min, Kyung-Won;Lee, Sang-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.561-567
    • /
    • 2007
  • This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.

  • PDF

Transverse vibration reduction at navigation bridge deck of the shuttle tanker using structural intensity analysis (진동 인텐시티 해석을 통한 원유운반선의 거주구 횡방향 진동 저감 연구)

  • Kim, Ki-Sun;Kim, Heui-Won;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.251-255
    • /
    • 2012
  • Structural intensity has been mainly utilized to identify vibration energy flow in a vessel. In this paper, the structural intensity of a shuttle tanker subjected to H-moment of the main engine was calculated using a finite element model. From the analysis, it was found that the top-bracing elements, which support the main engine onto the hull structure to prevent the excessive transverse vibration of the main engine, play the role of the dominant path and sink for vibration energy flow from the main engine. Therefore, the structural intensity was controlled by the modification of stiffness and damping characteristics of the top-bracing elements. As a result, it is observed that the transverse vibration level at the center of navigation bridge deck decreased after the control of structural intensity.

  • PDF

Effects by Bracing Reinforcement on Bifurcation of Cable Domes (케이블 돔 구조물의 분기좌굴에 대한 브레이싱 보강 효과)

  • 김민정;백인성;김형석;김승덕
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.167-174
    • /
    • 2001
  • A shape resistant shell structure is an extremely efficient mechanical creation because it transmits forces mainly by in-plane forces, but at a certain load level it changes from a stable condition to an unstable condition or vise versa. The instability phenomenon of Geiger-type cable dome structure is generated due to the in-plane twisting near critical load level. Therefore the effect of bracing reinforcement is investigated for the Geiger-type model reinforced by bracing. The effect of initial imperfection is also studied since the structural instability behavior characteristic of shell-like structure is significantly sensitive according to the initial condition.

  • PDF

Cyclic and static behaviors of CFT modular bridge pier with enhanced bracings

  • Kim, Dongwook;Jeon, Chiho;Shim, Changsu
    • Steel and Composite Structures
    • /
    • v.20 no.6
    • /
    • pp.1221-1236
    • /
    • 2016
  • Modular structures consist of standardized modules and their connections. A modular bridge pier is proposed to accelerate bridge construction. Multiple concrete-filled steel tubes (CFTs) using commercial steel tubes were chosen as the main members. Buckling restrained bracings and enhanced connection details were designed to prevent premature low-cycle fatigue failure upon cyclic loading. The pier had a height of 7.95 m, widths of 2.5 m and 2.0 m along the strong and weak axis, respectively. Cyclic tests were performed on the modular pier to investigate structural performance. Test results showed that four CFT columns reached yielding without a premature failure of the bracing connections. The ultimate capacity of the modular pier was reasonably estimated based on the plastic-hinge-analysis concept. The modular CFT pier with enhanced bracing showed improved displacement ductility without premature failure at the welding joints.

Retrofitting Effects of Seismic Resistance capacity of Reinforced Concrete Fraed Structure (철근콘크리트 구조물의 강재를 이용한 내진성능 보강효과)

  • Chung, Lan;Park, Hyun-Soo;Park, Tae-Won;Back, In-Kwan
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.281-288
    • /
    • 1999
  • This paper studied the efficiency of retrofitting of reinforced concrete structure which was not designed to endure an earthquake. The earthquake in Kobe Japan showed that there was a great possibility of having an earthquake even in big city and the damages were concentrated on mid or low story buildings which were not considered to be protected from an earthquake, . This experiment used reinforced concrete structure which restrained side-by-side displacement to test durability against an earthquake. This study deals with the structural performance of reinforced concrete frame structures strengthened with steel materials.

  • PDF

A review on BRB and SC-BRB members in building structures

  • Haider, Syed Muhammad Bilal;Lee, Dongkeun
    • Structural Engineering and Mechanics
    • /
    • v.80 no.5
    • /
    • pp.609-623
    • /
    • 2021
  • Buckling restrained bracing (BRB) was firstly introduced in Japan construction industry in year 1989. With time, BRB performance has been advanced to self-centering BRB (SC-BRB) which has exceptional energy dissipation, addressing the improvement in the structure performance in post-seismic affect. Although the BRB performance specifications are defined in design codes of several countries, specific design provisions are not generally provided since BRBs are usually considered a manufactured device. Furthermore, most of review papers focused on BRB rather than SC-BRB. Thus, this paper explores the background of both BRB and SC-BRB. The importance of self-centering components in BRB and literature related to it have been studied. This review study also highlights the significance of corrosion-resistance materials in the configuring BRB and SC-BRB since most of such members are made of carbon steel that is susceptible to corrosion.

Analysis of Seismic Performance Characteristics for School Buildings on the Bracing Configuration of Steel Frame System Reinforcement (철골 시스템보강의 가새 형태에 따른 학교건축물의 내진성능특성 분석)

  • Kim, Ho-Soo;Kim, So-Yeon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.59-69
    • /
    • 2023
  • Recently, the occurrence frequency of earthquake has increased in Korea, and the interests for seismic reinforcement of existing school buildings have been raised. To this end, the seismic performance evaluations for school buildings that did not accomplish the seismic design are required. In particular, this study checks the eigenvalue analysis, pushover curves, maximum base shears, performance points and story drift ratios, and then analyzes the seismic performance characteristics according to bracing configuration of steel frame system reinforcement. Also, this study presents the practical field application methods through the comparison of analysis results for the seismic performance characteristics.

Structural Performance Evaluation of a Multi-span Greenhouse with Venlo-type Roof According to Bracing Installation (가새 설치에 따른 벤로형 지붕 연동온실의 구조성능 평가)

  • Shin, Hyun Ho;Choi, Man Kwon;Cho, Myeong Whan;Kim, Jin Hyun;Seo, Tae Cheol;Lee, Choung Kuen;Kim, Seung Yu
    • Journal of Bio-Environment Control
    • /
    • v.31 no.4
    • /
    • pp.438-443
    • /
    • 2022
  • In this study, the lateral loading test was performed to analyze structural performance of multi-span plastic greenhouse through full-scale experiment and numerical analysis. In order to analyze the lateral stiffness and stress, we installed 9 displacement sensors and 19 strain gauge sensors on the specimen, respectively, and load of l mm per minute was applied until the specimen failure. In the comparison between the full-scale experiment and the structural analysis results of a multi-span greenhouse with venlo-type roof according to bracing installation, there was a large difference in the lateral stiffness of the structure. By installing a brace system, the lateral stiffness measured near the side elevation of the specimen increased by up 44%. As the bracing joint used in the field did not secure sufficient rigidity, the external force could not be transmitted to the entire structure properly. Therefore, it is necessary to establish a bracing construction method and design standards in order for a greenhouse to which bracing applied to have sufficient performance.