• 제목/요약/키워드: Brachytherapy

검색결과 240건 처리시간 0.024초

Impact of Treatment Time on Chemoradiotherapy in Locally Advanced Cervical Carcinoma

  • Pathy, Sushmita;Kumar, Lalit;Pandey, Ravindra Mohan;Upadhyay, Ashish;Roy, Soumyajit;Dadhwal, Vatsla;Madan, Renu;Chander, Subhash
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권12호
    • /
    • pp.5075-5079
    • /
    • 2015
  • Background: Adverse effects of treatment prolongation beyond 8 weeks with radiotherapy for cervical cancer have been established. Clinical data also show that cisplatin increases the biologically effective dose of radiotherapy. However, there are no data on the effect of overall treatment time in patients with locally advanced cervical cancer treated with concomitant chemo-radiotherapy (CCRT) in an Indian population. The present study concerned the feasibility of concurrent chemotherapy and interspacing brachytherapy during the course of external radiotherapy to reduce the overall treatment time and compare the normal tissue toxicity and loco-regional control with a conventional schedule. Materials and Methods: Between January 2009 and March 2012 fifty patients registered in the Gynaecologic Oncology Clinic of Institute Rotary Cancer Hospital with locally advanced cervical cancer (FIGO stage IIB-IIIB) were enrolled. The patients were randomly allocated to treatment arms based on a computer generated random number. Arm I (n=25) treatment consisted of irradiation of the whole pelvis to a dose of 50 Gy in 27 fractions, and weekly cisplatin $40mg/m^2$. High dose rate intra-cavitary brachytherapy (HDR-ICBT) was performed after one week of completion of external beam radiotherapy (EBRT). The prescribed dose for each session was 7Gy to point A for three insertions at one week intervals. Arm II (n=25) treatment consisted of irradiation of the whole pelvis to a dose of 50 Gy in 27 fractions. Mention HDR-ICBT ICRT was performed after 40Gy and 7Gy was delivered to point A for three insertions (days 23, 30, 37) at one week intervals. Cisplatin $20mg/m^2/day$ was administered from D1-5 and D24-28. Overall treatment time was taken from first day of EBRT to last day of HDR brachytherapy. The overall loco-regional response rate (ORR) was determined at 3 and 6 months. Results: A total of 46 patients completed the planned treatment. The overall treatment times in arm I and arm II were $65{\pm}12$ and $48{\pm}4$ days, respectively (p=0.001). At three and six months of follow-up the ORR for arm I was 96% while that for arm II was 88%. No statistically significant difference was apparent between the two arms. The overall rate of grade ${\geq}3$ toxicity was numerically higher in arm I (n=7) than in arm II (n=4) though statistical significance was not reached. None of the predefined prognostic factors like age, performance status, baseline haemoglobin level, tumour size, lymph node involvement, stage or histopathological subtype showed any impact on outcome. Conclusions: In the setting of concurrent chemoradiotherapy a shorter treatment schedule of 48 days may be feasible by interspacing brachytherapy during external irradiation. The response rates and toxicities were comparable.

Comparisons between the KKU-Model and Conventional Rectal Tubes as Markers for Checking Rectal Doses during Intracavitary Brachytherapy of Cervical Cancer

  • Padoongcharoen, Prawat;Krusun, Srichai;Palusuk, Voranipit;Pesee, Montien;Supaadirek, Chunsri;Thamronganantasakul, Komsan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6115-6120
    • /
    • 2014
  • Background: To compare the KKU-model rectal tube (KKU-tube) and the conventional rectal tube (CRT) for checking rectal doses during high-dose-rate intracavitary brachytherapy (HDR-ICBT) of cervical cancer. Materials and Methods: Between February 2010 and January 2011, thirty -two patients with cervical cancer were enrolled and treated with external beam radiotherapy (EBRT) and intracavitary brachytherapy (ICBT). The KKU-tube and CRT were applied intrarectally in the same patients at alternate sessions as references for calculation of rectal doses during ICBT. The gold standard references of rectum anatomical markers which are most proximal to radiation sources were anterior rectal walls (ARW) adjacent to the uterine cervix demonstrated by barium sulfate suspension enema. The calculated rectal doses derived from actual anterior rectal walls, CRT and the anterior surfaces of the KKU-tubes were compared by using the paired t-test. The pain caused by insertion of each type of rectal tube was assessed by the visual analogue scale (VAS). Results: The mean dose of CRT was lower than the mean dose of ARW ($Dmean_0-Dmean_1$) by $80.55{\pm}47.33cGy$ (p-value <0.05). The mean dose of the KKU-tube was lower than the mean dose of ARW ($Dmean_0-Dmean_2$) by $30.82{\pm}24.20cGy$ (p-value <0.05). The mean dose difference [($Dmean_0-Dmean_1$)-($Dmean_0-Dmean_2$)] was $49.72{\pm}51.60cGy$, which was statistically significant between 42.32 cGy -57.13 cGy with the t-value of 13.24 (p-value <0.05). The maximum rectal dose by using CRT was higher than the KKU-tube as much as 75.26 cGy and statistically significant with the t-score of 7.55 (p-value <0.05). The mean doses at the anterior rectal wall while using the CRTs and the KKU-tubes were not significantly different (p-value=0.09). The mean pain score during insertion of the CRT was significantly higher than the KKU-tube by a t-score of 6.15 (p-value <0.05) Conclusions: The KKU-model rectal tube was found to be an easily producible, applicable and reliable instrument as a reference for evaluating the rectal dose during ICBT of cervical cancer without negative effects on the patients.

방사선 근접치료에 있어서 핵자기공명영상을 이용한 3차원 방사선 선량분포도의 가시화를 위한 polymer 젤의 이용 (The Use of Polymer Gel for the Visualization of 3-D Dose Distribution in Brachytherapy Using Magnetic Resonance Imaging)

  • 강해진;조삼주;정은기;강승희;오영택;전미선;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.207-215
    • /
    • 1998
  • 방사선의 측정방법으로 현재까지 여러 방법들이 쓰여져 왔다. 여기에는 필름을 이용하는 방법, TLD를 이용하는 방법, 전리함(ion chamber)을 이용하는 방법 등이 대체로 가장 많이 쓰여지는 방법이다. 그러나 본 연구에서는 새로운 방사선측정 방법이 시도되었다. 고분자 젤과 핵자기공명영상 (MRI)을 이용한 방법이 그 것이다. 본 연구의 목적은 방사선 측정을 위한 고분자 젤을 합성하고 합성된 젤을 사용하여 젤의 방사선 흡수선량과의 관계를 MRI 영상으로부터 구해서, 이 결과를 근접치료에 쓰이는 seed 선원의 선량분포를 측정하여 가시화 시키는데 있다. 이를 위해 지름 12 cm 원통형 팬텀에 젤을 합성하고, 이 젤을 뇌정위 방사선수술에 쓰이는 30 mm 콜리메이터를 이용하여 여러 단계의 선량을 젤에 조사하였다. 이렇게 조사된 젤은 MRI 을 촬영하였고 이렇게 촬영된 MRI 영상으로부터 젤팬텀의 각 위치의 횡이완시간 (T$_2$ time)을 영상분석 소프트웨어를 이용하여 계산하였다. 그 결과 젤의 홉수선량과 횡이완시간과는 17 Gy 근처까지는 거의 반비례 ($R^2$=0.993)하는 것을 알 수 있었으며, 이 보다 높은 흡수선량에 대해서는 또 다른 관계가 있음을 알 수 있었다. 또 이것을 이용하여 HDR afterloading system 의 Ir-192 seed 선원에 의한 선량분포와 2 mCi Ir-192 seed 선원에 의한 선량분포를 측정하였다. 그리고 이 것을 각각 치료계획컴퓨터에 의한 선량분포곡선과 비교하였다. 본 연구의 결과로는 고분자 젤을 이용한 방사선의 측정방법을 시도하여 홉수선량과 젤의 특성과의 관계를 밝혔으며, 실제로 그접치료에 쓰이는 seed 선원에 의한 선량분포 곡선을 얻는데 적용하였다.

  • PDF

코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성 (Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source)

  • 최태진;이호준;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.259-266
    • /
    • 1998
  • 코발트-60 근접조사선원을 대체할 Ir-l92 선원주변의 2차원적 선량분포를 얻기 위하여, 조사선량률과, 조직감쇠계수를 구하였다. 조직감쇠계수는 선원에서 20 cm 지점까지 실험식을 구하였다. ?보기 방사능은 조사선량상수를 사용하여 결정하였으며, 2.5mm 직경에 두께 2.5 mm 의 선원은 조직선량을 정하기 위해 선원을 4401 개로 분할하여 선원 자체의 흡수효과와 ?슐벽의 차폐 효과와 조직감쇠계수를 적용하였다. 조직감쇠계수는 4차식을 사용하여 1% 오차범위내에서 실험값을 얻을 수 있었으며, Meisberger 상수는 선원에서 많이 떨어질수록 오차가 커서, 10 cm 위치서 7%, 20 cm 에서 33%의 오차를 발견할 수 있었으나, 겉보기방사능과 선원모양 및 크기가 달라 다른 결과를 가져올 수 있다고 본다. 발표된 Ir-192 선원의 에너지스펙트럼을 이용한 선량률상수는 절삭에너지 10 keV인 경우 4.69 R$cm^2$/mCi-hr을 얻었으며 Air Kerma는 0.973 을 구하였다. 이 실험에서 고안 선원의 분할선원에 의한 선원자체흡수와 ?슐벽에 의한 감쇠는 실선원의 54.6%가 겉보기방사능으로 나타남을 알 수 있었으며, 선량계획에 이용하기 위해 단위 ?보기 방사능에 대한 2차원적 선량표를 준비함으로써 기하학적선량과 선량 비등방성을 쉽게 이용할 수 있도록 하였다.

  • PDF

Institutional Experience of Interstitial Brachytherapy for Head and Neck Cancer with a Comparison of High- and Low Dose Rate Practice

  • Mohanti, Bidhu Kalyan;Sahai, Puja;Thakar, Alok;Sikka, Kapil;Bhasker, Suman;Sharma, Atul;Sharma, Seema;Bahadur, Sudhir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.813-818
    • /
    • 2014
  • Aims: To describe our institutional experience with high dose rate (HDR) interstitial brachytherapy (IBT) compared with previously reported results on the low dose rate (LDR) practice for head and neck cancer. Materials and Methods: Eighty-four patients with oral cavity (n=70) or oropharyngeal cancer (n=14) were treated with 192Ir HDR-IBT. Seventy-eight patients had stage I or II tumour. The patients treated with IBT alone (n=42) received 39-42 Gy/10-14 fractions (median=40 Gy/10 fractions). With respect to the combination therapy group (n=42), prescription dose comprised of 12-18 Gy/3-6 fractions (median=15 Gy/5 fractions) for IBT and 40-50 Gy/20-25 fractions (median=50 Gy/25 fractions) for external radiotherapy. Brachytherapy was given as 2 fractions per day 6 hours apart with 4 Gy per fraction for monotherapy and 3 Gy per fraction for combination therapy. Results: Four patients were not evaluable in the analysis of outcome. The primary site relapse rates were 23.8% (10/42) and 68.4% (26/38) in patients treated with IBT alone and combination therapy, respectively (p<0.001). Salvage surgery was performed in 19 patients. The 5-year local control rate was estimated at 62% and the disease-free survival (DFS) rate at 52% for all patients. Local control with respect to T1 and T2 tumours was 84% and 42%, respectively. Conclusions: Our present series on HDR-IBT and the previous report on LDR-IBT for head and neck cancer demonstrated similar DFS rates at 5 years (52%). The rate of regional failure in node-negative patients was <20% in both of our series. HDR-IBT offers similar results to LDR-IBT for head and neck cancer.

강내온열 치료를 위한 원통형 초음파 치료기 개발 (Development of a cylindrical ultrasound applicator for Intracavitary Hyperthermia)

  • Lee, Rena J.;Hyunsuk Suh
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2002
  • 항문암 및 자궁경부암 치료시 사용되는 고선량률 강내 근접치료기와 병행하여 사용할 원통형 초음파 온열치료가 개발되었다. 온열치료를 위한 에너지원으로 원통형 트랜스듀서가(PZT-8 물질, 길이=1.5 cm 두께=1.5 mm 외경= 2.5cm) 사용되었다. PZT-8 물질의 특성을 측정하기위해 세 개의 단일 엘리멘트 어플리케이터가 제작되었다. PZT 물질을 작동하기 위한 주파수를 결정하기 위하여 벡터 임피던스가 측정되었다. 선택된 물질이 온열치료에 사용될 수 있는지 가능성을 타진하기위해 방사능력을 측정하는 방법으로 각 엘리맨트의 초음파발생 효율을 입력한 전기량과 발생한 초음파량의 비로 계산하였다. 마지막으로 질암의 온열치료에 사용할 수 있는 다채널 초음파 치료기가 디자인 되었다. 임피던스 실험결과 각 엘리맨트 1, 2, 그리고 3에 대해 1.78, 1.77, 그리고 1.77 MHz의 주파수에서 최대 임피더스 값을 얻었다. 방사능력 측정 실험결과 본 연구에서 사용된 에너지 소스는 40와트 이상의 초음파량이 방출되었다. 또한 각 엘리맨트 1, 2, 그리고 3의 평균 효율은 61.4, 65.2, 그리고 54.0% 이다. 본 연구에서 디자인되어진 원통형 초음파 치료기는 질 또는 항문 치료 시 고선량 강내근접치료와 더불어 사용할 수 있음이 증명되었다. 따라서 본 연구에서 개발된 온열 치료기구가 고 선량 강내 근접치료와 함께 사용하여 병변조직의 방사능 민감도를 증가시켜 암 치료효율을 높일수 있다.

  • PDF

근접 방사선치료용 이리듐 선원의 선량분포에 대한 몬데칼로 시뮬레이션 (Monte Carlo Simulation for Dose Distributions from Ir-192 in Brachytherapy)

  • 김승곤;강정구;이정옥;정동혁;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.187-194
    • /
    • 2002
  • 본 연구에서는 근접 방사선치료용 Ir-192 선윈의 흡수선량에 관한 물리적 특성들을 몬테칼로 계산을 이용하여 조사하였다. 몬테칼로 계산은 EGS4 코드로 수행하였으며 이를 위하여 원통형 선원과 팬텀 그리고 에너지 분포의 입력과 처리가 가능한 사용자 코드를 작성하였다. 베타선에 대한 계산 결과, 베타선들은 선원과 0.5-5.0 cm 거리에서 전체 흡수선량에 평균 0.02% 기여하는 것으로 나타났다. 이것은 초기 베타선들이 선원과 밀봉물질에서 대부분 흡수를 당하지만 이 과정에서 발생한 저에너지 제동복사 광자들이 원거리까지 기여하기 때문이다. 밀봉물질에 의한 흡수선량의 변화는 백금으로 취한 경우에 평균 2.8% 그리고 철로 취한 경우에 평균 1.1% 감소하는 것으로 나타났다. 몬테칼로 계산으로 구한 반경선량함수는 선원과 0.5-10.0 cm 반경거리 구간에 대하여 TG-43 보고서의 값들과 $\pm$3% 이내로 일치하였다. 본 연구에서 작성한 사용자 코드는 다른 종류 및 다른 크기의 선원에 대해서도 계산을 수행할 수 있어서 근접 방사선치료용 선원의 생산 및 가공에 관한 연구에 다양하게 이용될 수 있다.

  • PDF

Application of Modified Mupit for the Recurrent Vulva Cancer in Brachytherapy

  • 김종식;정천영;오동균;송기원;박영환
    • 대한방사선치료학회:학술대회논문집
    • /
    • 대한방사선치료학회 2005년도 춘계학술대회 초록집
    • /
    • pp.23-26
    • /
    • 2005
  • 재발한 vulva tumor의 근접 치료에 있어서 정상조직의 장애와 tumor volume내의 dose uniformity는 치료성적에 매우 중요한 요인이다. 이를 개선하기 위하여 modified MUPIT applicator를 제작하여 modified MUPIT applicator의 적용에 대한 유용성을 평가하고자 한다. modified MUPIT applicator는 template, cylinder, interstitial needle로 구성되었으며, tumor volume을 정하기 위하여 CT를 시행하였다. CT image를 이용하여 interstitial needle의 삽입 위치를 확인하고 수술실에서 template 를 치료 부위에 고정을 시키고 cylinder를 vaginal cavity에 삽입한 후 interstitial needle을 tumor volume 내에 삽입 하였다. tumor volume내에서 interstitial needle의 정확한 위치를 확인하기 위하여 CT를 시행하였으며 orthogonal film을 이용하여 computer planning을 실시하였다. daily tumor dose는 600 cGy, BID로 3000 cGy를 조사하였으며 치료 시 rectal dose를 평가하기 위하여 TLD를 이용하여 anal verge를 기준으로 5개 지점에서 rectal dose를 측정하였다. rectal dose는 34.1 cGy, 57.1 cGy, 103.8 cGy, 162.7 cGy, 165.7 cGy로 측정되었으며 EBRT(whole pelvis RT), ICR과 overlap되는 지점은 34.1 cGy, 57.1 cGy로 매우 우수하게 평가되었다. 결론적으로 자체 제작한 modified MUPIT applicator 사용하여 interstitial brachytherapy를 시행함으로써 EBRT로 cover하기 어려운 환자의 tumor volume내에서 irregularity를 효율적으로 극복할 수 있었고 우수한 rectal dose 분포를 통하여 rectal complication의 발생 확률을 현저히 감소시킬 수 있었다.

  • PDF

자궁경부 선암 환자에서 고선량률 강내치료와 저선량률 강내치료의 비교 (High versus Low Dose-Rate Intracavitary Irradiation for Adenocarcinoma of the Uterine Cervix)

  • 김우철;김귀언;정은지;서창옥;홍순원;조영갑;노준규
    • Radiation Oncology Journal
    • /
    • 제18권1호
    • /
    • pp.32-39
    • /
    • 2000
  • 목적 : 자궁경부 선암은 발생률이 적어 편평상피암에 비하여 아직 치료방법에 대한 연구가 미흡하다. 또한 지금까지 저선량률 강내치료가 많이 사용되어 고선량률 강내치료의 결과는 많이 보고되고있지 않다. 따라서 저자들은 자궁경부 선암환자에서 고선량률 강내치료와 저선량률 강내치료를 비교하여 고선량률 강내치료의 효과를 알아보고자 하였다. 대상 및 방법 : 1971년 1월부터 1992년 12월까지 연세대학교 방사선종양학과에서 근치적 목적으로 치료된 106명의자궁경부 선암 환자를 대상으로 하였다. 저선량률 강내치료는 35명에서 시행되었고, 71명은 고선량률 강내치료가 시행되었다. 저선량률군에서는 병기 1기가 8명, 병기 2기가 18명, 병기 3기가 9명이었고 외부방사선치료는 10 MV X-ray를 이용하여 매일 2 Gy씩 총 40$\~$64 Gy (중앙값 48 Gy)가 조사되었다. 저선량률 강내치료는 radium 선원을 이용하여 Henshke applicator로 시행되었고 point A에 22$\~$59 Gy (중앙값 43 Gy)가 조사되었다. 고선량률군에서는 병기 1기가 16명, 병기 2기가 38명, 병기 3기가 17명 이었다. 외부방사선치료량은 40$\~$61 Gy (중앙값 45 Gy)이었고 분할선량은 1.8$\~$2.0 Gy이었다. 고선량률 강내치료는 Co-60 선원을 사용하여 RALS (remote afterloading system)로 분할선량 3 Gy를 주 3회 총 30$\~$57 Gy (중앙값 39 Gy)가 시행되었다. 결과 :저선량률군의 5년 생존률은 병기1, 2, 3기에서 각각 72.9, 61.9, 45.0$\%$이었고 고선량률군에서는 각각 87.1, 58.3, 41.2$\%$이었다(p>0.05). 자궁경부 선암에서 고선량률군과 저선량률군간의 5년 생존률에는 차이가 혀었다. 또한 양군간에 유의한 예후인자는 없었다. 고선량률군의 만성 합병증률은 26.8$\%$로 저선량률군의 11.4$\%$에 비하여 높았으나 대부분 grade 1의 경미한 정도이었고 통계학적인 차이가 없어 받아들일 만한 결과이었다. 결론 :자궁경부 선암 환자에서 고선량률 강내치료는 저선량률 강내치료에 비하여 5년 생존률과 치료실패율에서 차이를 보이지 않아 저선량률 강내치료를 대치할 수 있을 것으로 생각되나 병기 2기와 3기에서 만성 합병증이 높아 분할 선량에 대한 연구가 필요할 것으로 생각된다.

  • PDF

식도암 치료에 있어 관내근접치료의 역할 (The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer)

  • 이창걸;서창옥;김귀언;추성실;정은지;김우철
    • Radiation Oncology Journal
    • /
    • 제13권4호
    • /
    • pp.331-338
    • /
    • 1995
  • 목적 : 식도암의 치료는 진단당시 국소적으로 진행된 예가 대부분으로 방사선치료 단독 혹은 유도화학 및 방사선병행요법 등이 주로 시행되고 있다. 그러나 이들 치료에도 불구하고 5년 생존율은 $5-10{\%}$로 극히 저조한 결과를 보고하고 있다. 이처럼 치유율이 저조한 것은 $50{\%}$이상의 원격전이율외에 궁극적으로 원발병소의 재발율이 약 $80{\%}$에 달하는 까닭이다. 최근 동시 화학방사선 병행요법으로 생존율 향상을 보고하고 있으나 이역시 약 $50{\%}$의 높은 국소재발율을 보고하고 있어서 식도암의 치료에 있어 국소제어의 중요성은 아무리 강조해도 지나치지 않다. 이에 저자들은 방사선치료 단독 혹은 화학 방사선 병행치료후 관내근접치료를 시행하여 반응률, 치료에 따른 합병증, 국소제어율 그리고 궁극적으로 생존율 향상에 기여할 수 있는지 보고자 하였다. 방법 : 1989년 11원부터 1993년 3월까지 식도암으로 진단받고 연세암센터 방사선종양학과에서 근치적목적으로 방사선치료 단독(7예) 혹은 유도화학 및 방사선병행치료(13예)후 관내근접치료를 시행받은 환자 20명을 대상으로 하였다. 전 환자는 남자였고, 연령은 48세에서 82세(median 60.5세), 전신수행도 H1(ECOG)이상 그리고 편평상피세포암의 조직소견을 나타내었다. 발생부위별로는 경부 4예($20{\%}$), 상흉부 6예($30{\%}$), 중흉부 6예($30{\%}$) 그리고 하흉부 4예($20{\%}$)였다. 병기(AJCC)별로 11기 4예($20{\%}$), III기 15예($75{\%}$), IV기 1예($5{\%}$)였다. 방사선치료는 180-200cGy/fraction으로 원발병소를 포함하여 종격동 및 국소림프절 영역에 총 5900-6400cGy/6-7주(median 5940cGy) 조사하였고 2-8주후 관내 근접치료를 시행하였다. 관내방사선 근접치료는 고선량률 Iridium-192 동위원소를 이용한 Gamma-Med 12i를 사용하였고 지름이 5-6mm의 nasogastric tube를 식도내 삽입한후 원발병소부위에 고정시키고 원격조정으로 치료하였다. 방사선량은 300-500cGy/ fraction를 식도점막하 5mm에 조사하였고 1-4 fraction/1-3주, 총 500-1200cGy 조사하였다. 유도화학요법은 5-FU(1g/m2,d1-5), cis-platinum (80mg/m2,d6)을 1-6회(median 3회) 4주간격으로 시행하였다. 전환자에서 사망시까지 추적관찰되었으며 생존환자의 최소 추적기간은 13개월이었다. 결과 : 전체 환자의 정중앙 생존기간은 13.5개월, 1년 및 2년 생존율은 $65{\%},\;15.8{\%}$였다. 관내치료후 반응률은 완전관해 5예($25{\%}$), 부분관해a 7예($35{\%}$), 부분관해b 7예($35{\%}$), 무반응 3예($15{\%}$)였다. 외부방사선치료후 반응률이 부분관해a + 완전관해의 경우 관내근접치료의 부가로 $50{\%}$(4/8)의 국소제어율을 보였고 관내근접 치료후 완전관해가 유도된 환자에서는 $80{\%}$(4/5)의 높은 국소제어율을 나타냈다. 치료 실패양상은 국소재발이 $65{\%}$(13/20), 원격전이 $0{\%}$ 그리고 국소및 원격 동시재발 $15{\%}$(3/20)로 궁극적인 국소재발율이 $75{\%}$였다. 치료에 따른 합병증은 경미한 식도염 $55{\%}$(11예), 중증의 식도염 $10{\%}$(2예), 식도궤양 $10{\%}$(2예) 등이었으나 보조적인 치료후 모두 회복되었고 그리고 식도협착의 경우가 1예 있었다. 정중앙 생존기간을 치료군별(방사선 단독 vs. 화학방사선 : 13개월, 15개월), 병기별(II vs III : 15개월, 13.5개월), 병소의 길이(<5cm VS ${\geq}$ 5cm : 18개월, 13개월), T병기(T1-2 VS

  • PDF