• Title/Summary/Keyword: Boss valve

Search Result 4, Processing Time 0.021 seconds

Cavitation and Loss Reductions of Butterfly Valve by Modifying the Shaft Boss Profile (축 보스 형상 변형을 이용한 버터플라이 밸브의 캐비테이션과 유동손실 감소)

  • Kim, J.R.;Moon, Y.J.;Han, Y.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.605-608
    • /
    • 2008
  • In this paper, a numerical investigation of three-dimensional, two-phase flow field around a butterfly valve is conducted. The butterfly valves that have different opening angles, $10^{\circ}{\sim}90^{\circ}$, and two profiles of the shaft boss are compared with various cavitation numbers and Reynolds numbers. This paper focused on the flow analysis in the original butterfly valve and new design butterfly valve in order to decrease cavitation and loss. It is found that the butterfly valve with a cone-type shaft boss greatly reduces the cavitation and loss, compared to the original shaft boss by 20${\sim}$30%.

  • PDF

Study on Loss Reduction for Tilting Disk Check Valve Installed in Piping System (배관용 틸팅디스크 체크밸브의 손실저항 절감에 관한 연구)

  • Kim, J.H.;Park, J.H.;Lee, H.S.;Nam, S.H.;Hwang, S.H.
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.327-328
    • /
    • 2006
  • In generally, under the influence of over-pressure drop, serious problems such as cavitation, choked flow, flashing and vibration has been coming around the tilting disk check valve. A PIV experiment to examine the cause of energy loss has been performed and the improvement configuration of valve seat based on this visualization results is proposed. In the visualization results, flows in the piping system became instability under the influence of the shape of boss. This unstable flows induces sudden pressure drop in the piping system. So, we change the configuration of boss as a streamlined design to be stabilized the flows. A pressure measurement has been performed to know that the influence of the configuration change. In result, the rate of pressure loss reduction is about 22% at the position of No. 2 and 24.2% at the position of No. 6 in comparison with pre-improved shape.

  • PDF

A PIV Study on Loss Reduction for Tilting Disk Check Valve Installed in Piping System of Water Supply by PIV (PIV에 의한 상수도 배관용 틸팅디스크 체크 밸브의 손실저감에 관한 연구)

  • Kim, B.S.;Kim, J.H.;Lee, J.Y.;Kim, J.G.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.577-582
    • /
    • 2003
  • In generally, under the influence of over-pressure drop, serious problems such as cavitation, choked flow, flashing and vibration has been coming around the tilting disk check valve. A PIV experiment to examine the cause of energy loss has been performed and the improvement configuration of valve seat based on this visualization results is proposed. In the visualization results, flows in the piping system became instability under the influence of the shape of boss. This unstable flows induces sudden pressure drop in the piping system. So, we change the configuration of boss as a streamlined design to be stabilized the flows. A pressure measurement has been performed to know that the influence of the configuration change. In result, the rate of pressure loss reduction is about 22% at the position of No. 2 and 24.2% at the position of No. 6 in comparison with pre-improved shape.

  • PDF

Fabrication of a Micro Scent Injector (초소형 향 분사 모듈의 제작)

  • Park, Tae-Gyu;Yang, Sang-Sik;Kim, Yeong-Sik;Lee, Sang-U
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.12
    • /
    • pp.633-638
    • /
    • 2001
  • The paper presents the fabrication and test of a micro scent injector module. A micro scent injector module consists of an injector fabricated by micromachining, a scent cartridge and a controller. If a scent injection signal triggers the controller, it heats the scent liquid in the injector chamber and a scent liquid is vaporized. The increased vapor pressure opens a normally closed boss valve, and the scent vapor is injected through the opened nozzle. The liquid volume injected by the fabricated module is about $1\muell$ for one second at 2 W.

  • PDF