• Title/Summary/Keyword: Boric acid

Search Result 221, Processing Time 0.025 seconds

Combustion Characteristics of Cypress Specimens Painted with Solutions of Boron Compounds (붕소 화합물로 처리된 편백나무 시험편의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • The combustion characteristics of cypress wood coated with boric acid (BA) and ammonium pentaborate (APB) were examined using a cone calorimeter according to the ISO 5660-1 standard. As a result, the combined specimens of boric acid and ammonium pentaborate (BA/APB) led to an improved fire performance index due to their synergistic effect. In addition, the total heat release values of the specimen coated with the boron compounds were 6.1~14.1% lower than that of the base specimen. The total smoke release rate (TSR) of the specimens coated with the boron compound decreased throughout the combustion process, except for BA/APB. The maximum concentration of carbon monoxide was reduced by 15.8~25.5%. In general, wood treated with flame retardants has a lower fire hazard.

Redrying Fire - Retardant - Treated Structural Plywood (구조용(構造用) 내화처리(耐火處理) 합판(合板)의 재건조(再乾燥)에 관(關)한 연구(硏究))

  • Lee, Phil-Woo;Schaffer, E.L.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.1-21
    • /
    • 1981
  • Exterior grades of Douglas-fir and aspen plywood were impregnated with interior fire-retardant chemicals and redried under low-, intermediate-, and high-temperature drying conditions. Fire-retardant treatments included borax-boric acid, chromated zinc chloride, minalith, pyresote, and a commercial formulation. Drying processes included kiln and press-drying. Evaluated were drying rates and defects generated. The borax-boric acid and the commercial treatments redried at rates similar to water-treated controls. Other salt treatments were significantly slower drying and more defect prone. Chromated zinc chloride treatment was consistently the slowest drying and most defect prone. Press drying was three times faster at an equivalent temperature level. However, thickness shrinkage doubled because of 50 1b/in. platen pressure.

  • PDF

Physical and Mechanical Properties and Fire-endurance Characteristics of Recycled Particleboards

  • Suh, Jin-Suk;Han, Tae-Hyung;Park, Joo-Saeng;Park, Jong-Young
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.6
    • /
    • pp.475-486
    • /
    • 2008
  • In this study, fire-retardant chemicals were melt with mixed composition ratios of dibasic ammonium phosphate and each half of boric acid and borax in hot water, in which hammer-milled chips were immersed to increase swelling of waste particleboards. Also, fire-retardant treated particles from sawn lumber chip and recycled particleboard chip were composed in ratio of 70:30 in core layer to improve boards' properties. Retention ratio of fire-retardant chemicals for the particles for face layer was high due to high specific surface area, and that of sawn lumber chips was somewhat higher than that of recycled particleboard chips. The mixture of particles from sawn lumber chips and recycled PB of 70:30 in weight ratio exceeded bending strength of 100 $kgf/cm^2$. It seemed that the relatively greater portions of dibasic ammonium phosphate affected adversely to dimensional stability, however fire-retardants treatment resulted in distinct effect lowering formaldehyde emission such as $E_0$ type(0.5mg/$\ell$ or less) in KS F 3104. In fire-retardancy, the recycled boards with a mixed ratio of dibasic ammonium phosphate to boric acid borax(50:50 mixture) of 70% to 30% in weight satisfied fire-retardancy 3rd grade in KS F 2271, and also this composition from cone calorimeter test met same standard grade figuring total heat release of 4.6MJ/$m^2$.

  • PDF

Corrosion behavior of SA508 low alloy steels exposed to aerated boric acid solutions

  • Lim, Yun Soo;Hwang, Seong Sik;Kim, Dong Jin;Lee, Jong Yeon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1222-1230
    • /
    • 2020
  • The corrosion rates of the reactor pressure vessel materials of SA508 Grade 3 were measured using a weight loss method in aerated boric acid solutions to simulate the evaporation of leaked PWR primary water in an ambient environment. The corrosion behavior and products were examined using X-ray diffraction and electron microscopy. SA508 showed typical general corrosion characteristics. The corrosion rate increased steadily as the boron concentration was increased. As the immersion time elapsed, the corrosion rate slowly or rapidly decreased according to the oxidation reaction of iron. The corrosion rate showed a complicated pattern depending on the temperature; it increased gradually and then rapidly decreased again when reaching a certain transition temperature. The corrosion products of SA508 were found to be FeO(OH), Fe2O3, and Fe3O4. As the boron concentration decreased and the temperature was increased, the formation of Fe3O4 was more favorable as compared to the formation of FeO(OH) and Fe2O3. Consequently, the changes of the corrosion rate and behavior were closely related to the oxidation reaction of iron on the surface. The corrosive damage to SA508 appears to be most severe when the oxidation reaction is such that Fe2O3 forms as a corrosion product.

Effects of Operating Variables on the Conversion of Meta Boric Acid Formation in a Bubble Column Reactor (기포탑 반응기에서 조작변수가 meta 붕산 생성반응 전환율에 미치는 영향)

  • Cho, Soo-Haeng;Do, Jae-Bum;Kang, Y.
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.573-579
    • /
    • 1996
  • Effects of operating variables on the conversion of the formation reaction of meta boric acid from ortho boric acid in a laboratory-scale bubble column reactor were investigated to obtain the basic data which are indispensable for the design, scale-up, control, development and operation of industrial bubble column reactors. Reaction time and pressure, particle size of reactant and gas flow rate were chosen as experimental variables. Effects of the experimental variables on the gas holdup in the bubble column reactor were also discussed in relation to the conversion of reaction. From the results of this study, the optimum conditions were drawn as follows : Reaction time ; 35~40(min), reaction pressure ; 92~95(kPa), particle size ; under $0.6{\times}10^{-3}(m)$, gas flow rate ; 0.07~0.08(m/s).

  • PDF

Mechanical Properties of Fire-Retardant Treated Wood (내화처리 목재의 기계적 성질)

  • Lee, Hyun-Mi;Kim, Jong-Man;Byeon, Hee-Seop
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1-11
    • /
    • 2004
  • This study explored how simultaneous treatment of monoammonium phosphate (MAP) and boric acid for Pinus densiflora and Populus euramericana influenced the properties such as fire resistance, preservation against Trametes versicolor and Tyromyces palustris, and compressive strength of the treated woods. For specific gravity and compressive strength, the treated woods were higher than the non-treated ones. For the analytical features observed by SEM, the cell walls of the non-treated woods were extremely destructed by T. palustris and T. versicolor while the treated ones relatively remained intact. Especially, P euramericana was more readily exposed to the attack of the rot fungi than P. densiflora.

Effect of Foliar Application of Boron on Growth and Yield in Sesame (붕소 엽면시비가 참깨가 생육 및 수량에 미치는 영향)

  • 정병관;김동관
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.4
    • /
    • pp.441-449
    • /
    • 1996
  • This study was conducted to find the changes of growth, seed yield and several characteristics of sesame by leaf spray of boron as a solution which is likely to be lack in the soil. It is carried out at low land developed 5 years ago. The amount of 200l /l0a boron as boric acid is sprayed in each treatment at the 11 node stage of sesame in main stem. The spraying concentrations of boric acid are 0.0, 0.2 and 0.4% in each treatment of the level low plot and the ridge height 15cm plot. The result shows that leaf area is increased in proportion to the concentration of boric acid in each treatment of the level low and the ridge height 15cm, and the degree of increase of each node order is remarkable in lower leaves and is more remarkable in the treatment of level low plot. The effects of leaf spray of boric acid are not only the increase of leaf area but also dry weight, no. of capsule per plant, 1,000 grains weight of capsule setting under middle position. As a result, the amount of seed is increased in 53% in the treatment of level low. The change of major characteristics according to leaf spray of boric acid is generally great in the treatment of level low. Especially the increase of leaf area in the part of upper leaves and low leaves is effective to improve other characteristics.

  • PDF

Rapid Analysis of Boric Acid in Nickel Plating Solutions (니켈도금액중의 붕산 신속정량법)

  • 염희택
    • Journal of the Korean institute of surface engineering
    • /
    • v.3 no.1
    • /
    • pp.7-12
    • /
    • 1970
  • Only mannitol or glycerine is generally used for the determination of boric acid in a nickel plating solution in order to make its acidic property so strong that it can be titrated with NaOH. However, these solutions give very amgiguous color change of indicator due to the precipitation of nickel salts . Therefore, only experienced dchemistsorwell trained workimen can accurately confirm the actual end point of the titratiion. For eliminating such interference of nickel salts and easily confirming the end point by any persons , the author attempted to find out a solution which produces no precipitates during the titration in these experiments, and also he tried to funish the reason for ambiguousness in titration. The following results were obtained after many experiments. (1) In any titrations which produce nickel salts such nI(oh)$_2$, the salt is formed umption very approximate to the end point, which shows some error by the consumption of titrant(NaOH) . Then, the pink color of phenolphthalein is absorbed by Ni(OH)$_2$ and the pH jumping at the end pint is also diminished to as little as less than 15% of the total phenophthalein ph range. (2) Known methods by complex salts of citrate,w hich do not produce precipitates of Ni(OH)$_2$, are also not very satisfactory, because, the pH jumping at the end point is only about 35% and the color change of phenolphthalein is form blue-green to purple-blue. (3) New method by complex salts of oxalate were attempted in these experiments. They also did not produce precipitates of Ni(OH)$_2$ and were very satisfactory in color change at the end of point was about 65% and the color change was from blue-green to purpled. In this methods, analytica cost was minimized by the use of less amounts of cheaper chemicals than the conventional citrates complex methods. The mixture of chemicals used was composed methods. The mixture of chemical used was composed of 37g/ι of sodium oxalate(Na$_2$C$_2$O$_4$$.$5H$_2$O), 2g/ι of phenolphthalein, and 400ml /ι of glycerin. The accuracy of analysis was within the error of 0.5%. (4) The procedure of analysis was as follows. One ml of nickel plating solution was taken out and to it were added 20ml of water and 20 ml of the above mixture for the indicator. The solution was titrated with 0.1N NaOH. The quantity of boric acid was calculated by the following equation. Boric acid (g/ι) = 6.184${\times}$F${\times}$ml .

  • PDF

Smoke Hazard Assessment of Cypress Wood Coated with Boron/Silicon Sol Compounds (붕소/실리콘 졸 화합물로 도포된 편백 목재의 연기유해성 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • In this study, boron/silicon sol compounds were applied to wood for construction and durable materials, and fire risks were investigated in terms of smoke performance index (SPI), smoke growth index (SGI), and smoke intensity (SI). The compound was synthesized by reacting tetraethoxyorthosilicate with boric acid and boronic acid derivatives. Smoke characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment for cypress wood. The fire intensity fixed the external heat flux at 50 kW/㎡. The smoke performance index measured after the combustion reaction increased between 13.4% and 126.7% compared with cypress wood. The fire risk due to the smoke performance index decreased in the order of cypress, phenylboronic acid/silicon sol (PBA/Si), (2-methylpropyl) boronic acid/silicon sol (IBBA/Si), boric acid/silicon sol (BA/Si). The smoke growth index decreased between 12.0% and 57.5% compared to the base specimen. The risk of fire caused by the smoke growth index decreased in the order of cypress, PBA/Si, IBBA/Si, BA/Si. The fire risk due to smoke intensity decreased between 3.2% and 57.8%, and in the order of cypress, PBA/Si, IBBA/Si, BA/Si. COpeak concentrations ranged between 85 and 93 ppm, and decreased between 37% and 43% compared to the base specimen. A comprehensive assessment of the fire risk on smoke hazards decreased in the order of cypress, PBA/Si, IBBA/Si, BA/Si.