• 제목/요약/키워드: Bone suppression imaging

검색결과 5건 처리시간 0.016초

Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction

  • Kyungsoo Bae;Dong Yul Oh;Il Dong Yun;Kyung Nyeo Jeon
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.139-149
    • /
    • 2022
  • Objective: To compare the effects of bone suppression imaging using deep learning (BSp-DL) based on a generative adversarial network (GAN) and bone subtraction imaging using a dual energy technique (BSt-DE) on radiologists' performance for pulmonary nodule detection on chest radiographs (CXRs). Materials and Methods: A total of 111 adults, including 49 patients with 83 pulmonary nodules, who underwent both CXR using the dual energy technique and chest CT, were enrolled. Using CT as a reference, two independent radiologists evaluated CXR images for the presence or absence of pulmonary nodules in three reading sessions (standard CXR, BSt-DE CXR, and BSp-DL CXR). Person-wise and nodule-wise performances were assessed using receiver-operating characteristic (ROC) and alternative free-response ROC (AFROC) curve analyses, respectively. Subgroup analyses based on nodule size, location, and the presence of overlapping bones were performed. Results: BSt-DE with an area under the AFROC curve (AUAFROC) of 0.996 and 0.976 for readers 1 and 2, respectively, and BSp-DL with AUAFROC of 0.981 and 0.958, respectively, showed better nodule-wise performance than standard CXR (AUAFROC of 0.907 and 0.808, respectively; p ≤ 0.005). In the person-wise analysis, BSp-DL with an area under the ROC curve (AUROC) of 0.984 and 0.931 for readers 1 and 2, respectively, showed better performance than standard CXR (AUROC of 0.915 and 0.798, respectively; p ≤ 0.011) and comparable performance to BSt-DE (AUROC of 0.988 and 0.974; p ≥ 0.064). BSt-DE and BSp-DL were superior to standard CXR for detecting nodules overlapping with bones (p < 0.017) or in the upper/middle lung zone (p < 0.017). BSt-DE was superior (p < 0.017) to BSp-DL in detecting peripheral and sub-centimeter nodules. Conclusion: BSp-DL (GAN-based bone suppression) showed comparable performance to BSt-DE and can improve radiologists' performance in detecting pulmonary nodules on CXRs. Nevertheless, for better delineation of small and peripheral nodules, further technical improvements are required.

정형 보철용 금속이 자기공명영상에 미치는 영향 III (Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III)

  • 김형균;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법 (Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression)

  • 조경은;윤춘식;송호택;이영한;임대건;서진석;김성준
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권2호
    • /
    • pp.110-122
    • /
    • 2013
  • 목적: 발목관절 VISTA 자기공명영상을 이용하여 지방억제를 한 것과 하지 않은 VISTA 사이에서 정량평가를 하며, 발목 인대의 traceability 차이를 알아보고자 하였다. 대상과 방법: SNR의 비교를 위해 팬텀과 한명의 자원자에서 자기공명영상을 촬영하였다. CR (contrast ratio)과 인대 traceability 비교를 위해 발목 관절의 외상 과거력이 없는 10명의 자원자에서 자기공명영상을 촬영하였다. 모든 자기공명영상은 VISTA를 이용하였고 3T에서 촬영하였다. 지방억제는 SPAIR (Spectral Attenuated Inversion Recovery) 기법을 이용하였다. SNR은 피검자가 있을 때와 피검자 없이 촬영한 것으로 구하였다. CR은 열개의 오른쪽 발목관절의 관절액-힘줄, 관절액-연골, 관절액-인대, 지방-힘줄, 지방-연골, 지방-인대의 신호강도를 얻어 구하였다. 두 명의 근골격계 영상의학과 의사가 지방억제를 한 것과 하지 않은 영상을 calcaneofibular ligament (CFL)을 포함한 7개의 발목관절 인대에 대해서 점수를 매겼다 (1, not traceable; 2, barely traceable; 3, adequately traceable; 4, excellently traceable). VISTA 와 VISTA SPAIR 사이에 CR을 비교하는 데는 Wilcoxon signed-rank test를 이용하였다. VISTA 와 VISTA SPAIR사이에 인대 traceability를 비교하는 데에는 Fisher's exact test와 Pearson's chi-squared test를 이용하였다. 결과: 정량평가의 SNR을 보면 지방억제를 하지 않은 영상에 비해 지방억제를 한 자원자의 골수에서 더 낮은 수치를 나타내었다. (7.65 versus [vs.] 36.64). 관절액, 연골, 근육에서는 두 연쇄간에 SNR의 차이가 없었다. 지방억제 VISTA는 관절액-인대 사이 CR만 더 나은 결과를 보여주었지만 (p=0.04) VISTA는 지방-힘줄, 지방-연골, 지방-인대 간에서 모두 더 나은 CR값을 나타내었다(P=0.005). CFL 인대만 통계학적으로 의미 있는 값을 보였는데 지방억제를 하지 않은 VISTA 영상에서 traceability의 값이 더 우세 하였다(p <0.05). 결론: 지방 억제를 한 VISTA와 하지 않은 VISTA에서 유의한 SNR 차이는 골수를 제외하고 없었다. 지방억제를 하지 않은 VISTA에서 CFL을 trace하는데 있어서 더 유리하였다.

견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구 (A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor)

  • 박의철;배석환;류연철;박영준;김용권
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.513-519
    • /
    • 2021
  • 봉합 나사못을 이용한 견관절 수술 환자들의 예후를 확인하기 위하여 MRI(Magnetic Resonance Imaging)를 이용하여 추적검사를 시행한다. 봉합나사못을 삽입한 경우에는 임상적 관찰을 용이하게 하기 위하여 지방소거법을 이용한 영상촬영 기법이 이용되는데, 이때 이용되는 지방 신호 억제 기법으로 CHESS(Chemical Shift Selective), STIR(Short Tau Inversion Recovery), Dixon 기법 등이 주로 이용되고 있다. 봉합나사못은 비자성 재료를 이용해서 제작되지만, 환부에 삽입되는 티타늄 재질의 금속물질은 비자성체임에도 불구하고 국소자장을 왜곡시켜 결과 영상의 기하학적인 왜곡은 물론 심각한 영상신호의 감소 현상을 발생시킨다. 봉합나사못을 삽입하여 환부를 관찰하는 경우에는 뼈 혹은 뼈 인접 부위의 영상을 획득하여야 하는데 뼈와 주변 조직의 임상적 관찰을 위해서는 뼈의 지방 신호를 억제할 필요가 있다. 이때 이용되는 지방 신호 억제 기법은 금속 삽입물로 인한 자기장 불균일의 영향을 받는다. 본 연구에서는 3가지 지방억제 영상기법(CHESS, STIR, Dixon)을 이용하여 금속물질을 삽입한 환자로부터 영상을 획득하여 비교, 분석하였으며, 그 결과로 봉합나사못을 삽입한 환자의 병변 관찰 및 수술 후 예후를 관찰하기 위한 영상기법으로 STIR 영상기법이 가장 적합함을 알 수 있었다. 연구 결과에 따르면 금속 물질을 인체에 삽입한 환자의 경우, 지방 신호 억제가 필요한 MRI 검사에서는 STIR 기법을 이용하는 것이 임상적 가치가 높은 영상을 얻을 수 있을 것이다.