• Title/Summary/Keyword: Bone screws

Search Result 184, Processing Time 0.026 seconds

CONSERVATIVE TREATMENT OF BILATERAL CONDYLAR FRACTURE BY A SIMPLIFIED TECHNIQUE OF MAXILLOMANDIBULAR FIXATION (단순악간고정법을 이용한 양측성 하악과두골절의 보존적 치료)

  • Kim, Jong-Pil;Ahn, Sang-Hun;Chang, Heon-Soo;Park, Jae-Bum;Jo, Byung-Woan;Ann, Jye-Jynn
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.2
    • /
    • pp.171-179
    • /
    • 1995
  • The conservative treatment of the condylar fracture has been used for a long time because of its simplicity, good prognosis and less complication. Traditionally the conservative treatment has been carried out by maxillomandibular fixation using arch bar and wire. But a simplified technique of maxillomandibular fixation introduced here is a procedure that 4 bone screws are placed above the apecies of the maxillary and mandibular canines and then ipsilaterally placed maxillary and mandibular bone screws are linked by a loop of wire each other. This procedure has several advantages compared with the traditional maxillomandibular fixation method. 1) it provides simplicity for the operators. 2) it sustains maxillomandibular fixation more rigidly compared with arch bar technique. 3) it keeps stable maxillomandibular fixation in the region of the anterior teeth so that anterior open bite tendency can be remarkably minimized. 4) it does not injure the periodontal tissue because the teeth are not engaged and causes less discomfort to the patient. 5) it decreases the possibility of operator's AIDS infection through inadvertent skin puncture. 6) it is highly recommended for the patients whose teeth are available for maxillomandibular fixation. The two male patients were diagnosed as bilateral condylar and symphyseal fracture of the mandible. They restored stable occlusion and functional mandibular movement only by a simplified technique of maxillomandibular fixation.

  • PDF

Ankle Arthrodesis using Cannulated Screws & Hybrid Type Rigid External Fixation in Diabetic Charcot Neuroarthropathy (유관 나사 및 Hybrid형 외고정술을 이용한 당뇨병성 샤르코 족관절 신경관절병증의 관절 유합술)

  • Han, Kyeung-Jin;Roh, Hyong-Rae;Han, Seung-Hwan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.140-145
    • /
    • 2010
  • Purpose: The diabetic charcot neuroarthropathy of ankle is an infrequent site (around 5%), but is definitely the location that, because of the instability and progressive deformity it involves, cause ulceration in a high percentage of patients, and this can then become a reason for amputation. However, the treatment of this disastrous disease is still challenging. We analyzed the clinical and radiological results of ankle arthrodesis by our fixation method in Charcot neuroarthropathy. Materials and Methods: Seven cases that were diagnosed as charcot neuroarthropathy of ankle arthrodesis were followed for more than 16 months postoperatively. Mean age was 57 years, and the mean follow-up period was 27 months. Anterior approach was used in arthrodesis, and internal fixation by 3 or more cannulated screws and hybrid type external fixation were used. Auto iliac bone for grafting was combined in all cases. External fixator was kept for 3 months without weight-bearing. Then, boots brace was applied for more 3 months allowing partial weight-bearing. Four cases had minor complications such as pin site infection. Preoperative and postoperative AOFAS score, time to fusion and postoperative complications were checked. Results: Postoperative fusion was completed in all cases, and the mean time to fusion was 3.4 months. No postoperative complication was checked. At the last follow-up, the mean AOFAS score had increased from 54 points to 72 points. Patient's satisfaction was over 80%. Conclusion: Satisfactory results were obtained after ankle arthrodesis using internal and hybrid type external fixation combined with auto iliac bone graft in charcot neuroarthropathy with minor complications.

Subservient Bone Reduction with Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate) in Hand Fractures: Two Cases of Report (수부 골절 시 Histoacryl$^{(R)}$ (N-butyl-2-cyanoacrylate)을 이용한 보조적 골 정복 2례)

  • Lee, Won;Lee, Sung-Hwan;Oh, Sang-A;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.102-104
    • /
    • 2011
  • Purpose: The standard treatments of hand fractures today are fixations by K -wires, metal plates, wires and lag screws. But it is very difficult to reconstruct fractures by placing implants into small bony fragments especially in the comminuted fractures and intra-articular fractures. This paper describes a simple method of reconstruction with Histoacryl$^{(R)}$ for comminuted and intra-articular fractures in hands. Methods: 2 cases with comminuted and intra-articular fractures by crushing injury were reconstructed with Histoacryl$^{(R)}$. We performed applying Histoacryl$^{(R)}$ with swab on the bone cortex carefully to avoid Histoacryl$^{(R)}$ infiltrating into the medulla. We could rearrange and fixate bony fragments using only Histoacryl$^{(R)}$, in addition, metal plates, K-wires, wires, and lag screws could be used for secondary fixation if needed. Results: Post-operative X-ray finding of 2 patients assured that the bony fragments of the hand fractures maintained their original positions. Significant displacement and deviation, infection, nonunion, and malunion during the follow-up period were not observed. Conclusion: This study showed the possibility of using Histoacryl$^{(R)}$ in addition as a simple method of fixation in the comminuted and intra-articular hand fractures.

Outcomes of Internal Fixation with Compression Hip Screws in Lateral Decubitus Position for Treatment of Femoral Intertrochanteric Fractures

  • Park, Cheon-Gon;Yoon, Taek-Rim;Park, Kyung-Soon
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Purpose: Internal fixation using compression hip screws (CHS) and traction tables placing patients in the supine position is a gold standard option for treating intertrochanteric fractures; however, at our institution, we approach this treatment with patients in a lateral decubitus position. Here, the results of 100 consecutive elderly (i.e., ${\geq}45$ years of age) patients who underwent internal fixation with CHS in lateral decubitus position are analyzed. Materials and Methods: Between March 2009 and May 2011, 100 consecutive elderly patients who underwent internal fixation with CHS for femoral intertrochanteric fracture were retrospectively reviewed. Clinical outcomes (i.e., Koval score, Harris hip score [HHS]) and radiographic outcomes (i.e., bone union time, amount of sliding of lag screw, tip-apex distance [TAD]) were evaluated. Results: Clinical assessments revealed that the average postoperative Koval score decreased from 1.4 to 2.6 (range, 0-5; P<0.05); HHS was 85 (range, 72-90); and mean bone union time was 5.0 (range, 2.0-8.2) months. Radiographic assessments revealed that anteroposterior average TAD was 6.95 (range, 1.27-14.63) mm; lateral average TAD was 7.26 (range, 1.20-18.43) mm; total average TAD was 14.21 (range, 2.47-28.66) mm; average lag screw sliding was 4.63 (range, 0-44.81) mm; and average angulation was varus $0.72^{\circ}$(range, $-7.6^{\circ}-12.7^{\circ}$). There were no cases of screw tip migration or nonunion, however, there were four cases of excessive screw sliding and six cases of varus angulation at more than $5^{\circ}$. Conclusion: CHS fixation in lateral decubitus position provides favorable clinical and radiological outcomes. This technique is advisable for regular CHS fixation of intertrochanteric fractures.

Insertion and removal torques according to orthodontic mini-screw design (교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크)

  • Cha, Jung-Yul;Yoon, Tae-Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.5-12
    • /
    • 2008
  • Objective: This study was designed to analyze the primary and secondary stability characteristics of orthodontic mini-screws of tapered design when compared with the cylinder mini-screw. Methods: A total of 48 mini-screws were placed into the buccal alveolar bone of the mandible in 6 male beagle dogs. Comparison was made between tapered and cylinder type mini-screws (Biomaterials Korea, Seoul, Korea). Maximum insertion torque (MIT) was measured using a torque sensor (Mark-10, MGT 50, USA) during installation, and maximum removal torque (MRT) was recorded after 3 and 12 weeks of loading. Results: Taper mini-screws showed a higher MIT value of 22.3 Ncm compared with cylinder mini-screw showing 13.6 Ncm (p < 0.001). The MRT of the taper mini-screw showed a significantly higher value of 9.1 Ncm than those of cylinder mini-screw of 5.7 Ncm at 3-weeks after installation (p < 0.05). However, there was no difference in the MRT value between the taper and cylinder mini-screws at 12 weeks of loading. Conclusions: These results showed that the high insertion torque of the taper mini-screw design increases initial stability until 3 weeks of loading, but does not have any effect on the secondary stability at 12 weeks of loading.

HISTOLOGIC STUDY OF VARIOUS DENTAL IMPLANT-TISSUE INTERFACE (수종의 치근형 골내매식체와 조직간의 반응에 관한 조직학적 연구)

  • Lee, Ho-Young;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.7-23
    • /
    • 1990
  • The success or failure of endosseous dental implants is related to the cellular activity at the implant surface. Success seems to be associated with the enclosure of the implant in a non-inflammed connective tissue or the formation of a direct bone implant interface. The purpose of this study was to examine the tissue reactions to the various implants at the submergible state in dog mandible. The $Br\"{a}nemark$, Core-Vent, Intergral, Bone spiral were selected for evaluation and also the Kimplant, Nephrite were used for the experimental study. After 4 months the animals were sacrificed. The interface zone between bone and implant was investigated using x-rays, light microscope, scanning electron microscope, transmission electron microscope. The following results were obtained from this study. 1. $Br\"{a}nemark$, Core-Vent, Kimplant, Integral showed no mobility and bone growth over the healing screws of the implants. Histologically most of the implant surface were covered by remodelled lamellar bone, and partly by a cellular layer or the thin fibrous tissue layer. 2. The Bone spiral showed no mobility and partially radiolucent line around the implant. The upper part of the implant was surrounded by a thin fibrous connective tissue and the middle, apical part of it were contacted with bone directly. 3. The Nephrite implant showed severe mobility and a radiolucent line around the implant. Histologically it showed mild inflammation and was surrounded by a fibrous connective tissue. 4. Scanning electron microscope showed that there was no amorphous ground substance in the Nephrite implant but the formation of ground substance over the collagen filaments in other implants. 5. Transmission electron microscope showed that collagen filaments were approached irregularly to the surface of all implants and in the $Br\"{a}nemark$, Core-Vent, Kimplant, Integral there was amorphous layer between the implant and the collagen filaments. It seemed to be ground substances.

  • PDF

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Fractal analysis of the surgical treatment of ligature-induced peri-implantitis in dogs (임플란트 주위염 치료 효과의 프랙탈 분석)

  • Kim, Hak-Kun;Kim, Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose : To evaluate the effect of surgical treatment of ligature-induced peri-implantitis in dogs using fractal analysis. Also, the capabilities of fractal analysis as bone analysis techniques were compared with those of histomorphometric analysis. Materials and Methods : A total of 24 implants were inserted in 6 dogs. After a 3-months, experimental periimplantitis characterized by a bone loss of about 3 mm was established by inducing with wires. Surgical treatment involving flap procedure, debridement of implants surface with chlorhexidine and saline (group 1), guided bone regeneration (GBR) with absorbable collagen membrane and mineralized bone graft (group 2), and $CO_2$ laser application with GBR (group 3) were performed. After animals were sacrificed in 8 and 16 weeks respectively, bone sections including implants were made. Fractal dimensions were calculated by box-counting method on the skeletonized images, made from each region of interest, including five screws at medial and distal aspects of implant, were selected. Results : Statistically significant differences in the fractal dimensions between the group 1($0.9340{\pm}0.0126$) and group 3($0.9783{\pm}0.0118$) at 16 weeks were found (P<0.05). The fractal dimension was statistically significant different between 8($0.9395{\pm}0.0283$) and 16 weeks in group 3 (P<0.05). These results were similar with the result of the evaluation of new bone formation in histomorphometric analysis. Conclusions : Treatment of experimental peri-implantitis by using $CO_2$ laser with GBR is more useful than other treatments in the formation of new bone and also the tendency of fractal dimension to increase relative to healing time may be a useful means of evaluating.

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

A Case Report of an Immediate Frontal Sinus Reconstruction Using an Outer Table Calvarial Bone Graft in an En Bloc Manner (전두동 골절 환자에서 머리덮개뼈의 바깥판을 한판으로 이용한 즉시 전두동 재건술 1례)

  • Kim, Jong Do;Kim, Jeong Tae;Kim, Youn Hwan
    • Archives of Craniofacial Surgery
    • /
    • v.12 no.1
    • /
    • pp.33-36
    • /
    • 2011
  • Background: In a frontal sinus reconstruction, the literature primarily recommends a surgical approach for definite treatment with the exception of for anterior wall fractures with no dislocation. Many studies have assessed a range of methods for the reduction of frontal sinus fractures. This paper presents a case, in whom the anterior wall of the frontal sinus was reconstructed using an outer table calvarial bone graft in an en bloc manner. Patient and methods: A 36-year-old male visited the emergency room with a heavy injury to the forehead. He was diagnosed with fractures of the anterior and posterior wall of the frontal sinus. The neurosurgeon removed the fractured area and repaired the meninges. Afterwards, cranialization was performed and the opening of the nasofrontal duct was obstructed. After fixing the removed bone to its original location, all fragments of fractured anterior wall were purged out and the anterior wall reconstructed using an en bloc calvarial bone graft. Results: In the post-operative 8 months period, there were no complications, the round contour of the forehead was expressed well and the patient was satisfied with the result. Conclusion: There are many methods for reconstructing the anterior wall of the frontal sinus. On the other hand, in cases of large fracture sites with many fractured bone fragments, en bloc harvesting of the outer table calvarial bone could be a better choice than making use of only plates and screws because this method shows a good results in terms of aesthetics with a low complication rate.