Kim, Jae Wook;Park, Seung Won;Kim, Young Baeg;Ko, Myeong Jin
Journal of Korean Neurosurgical Society
/
제61권4호
/
pp.494-502
/
2018
Objective : The loosening of pedicle screws (PS) is one of the frequent problems of spinal surgery in the patients with osteoporosis. Previous studies had revealed that intermittent injection of teriparatide could reduce PS loosening by improving bone mass and quality when their patients took parathyroid hormone for a considerable duration before surgery. However, although the teriparatide is usually used after spine surgery in most clinical situations, there was no report on the efficacy of teriparatide treatment started after spine surgery. The purpose of this retrospective study was to examine the efficacy of teriparatide treatment started immediately after lumbar spinal surgery to prevent pedicle screw loosening in patients with osteoporosis. Methods : We included 84 patients with osteoporosis and degenerative lumbar disease who underwent transforaminal interbody fusion and PS fixation and received parathyroid hormone or bisphosphonate (BP) postoperatively. They were divided into teriparatide group (daily injection of $20{\mu}g$ of teriparatide for 6 months, 33 patients, 172 screws) and BP group (weekly oral administration of 35 mg of risedronate, 51 patients, 262 screws). Both groups received calcium (500 mg/day) and cholecalciferol (1000 IU/day) together. The screw loosening was evaluated with simple radiographic exams at 6 and 12 months after the surgery. We counted the number of patients with PS loosening and the number of loosened PS, and compared them between the two groups. Clinical outcomes were evaluated using visual analog scale (VAS) and Oswestry disability index (ODI) preoperatively, and at 12 months after surgery. Results : There was no significant difference in the age, sex, diabetes, smoking, bone mineral density, body mass index, and the number of fusion levels between the two groups. The number of PS loosening within 6 months after surgery did not show a significant difference between the teriparatide group (6.9%, 12/172) and the BP group (6.8%, 18/272). However, during 6-12 months after surgery, it was significantly lower in the teriparatide group (2.3%, 4/172) than the BP group (9.2%, 24/272) (p<0.05). There was no significant difference in the number of patients showing PS loosening between the teriparatide and BP groups. The teriparatide group showed a significantly higher degree of improvement of the bone mineral density (T-score) than that of BP group (p<0.05). There was no significant difference in the pre- and post-operative VAS and ODI between the groups. Conclusion : Our data suggest that the teriparatide treatment starting immediately after lumbar spinal fusion surgery could reduce PS loosening compared to BP.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제30권4호
/
pp.331-338
/
2004
Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.
Objective : Bilateral C1 lateral mass and C2 pedicle screw fixation (C1LM-C2P) is an ideal technique for correcting atlantoaxial instability (AAI). However, the inevitable situation of vertebral artery injury or unfavorable bone structure may necessitate the use of unilateral C1LM-C2P. This study compares the fusion rates of the C1 lateral mass and C2 pedicle screw in the unilateral and bilateral methods. Methods : Over five years, C1LM-C2P was performed in 25 patients with AAI in our institute. Preoperative studies including cervical X-ray, three-dimensional computed tomography (CT), CT angiogram, and magnetic resonance imaging were performed. To evaluate bony fusion, measurements of the atlanto-dental interval (ADI) and CT scans were performed in the preoperative period, immediate postoperative period, and postoperatively at 1, 3, 6, and 12 months. Results : Unilateral C1LM-C2P was performed in 11 patients (44%). The need to perform unilateral C1LM-C2P was due to anomalous course of the vertebral artery in eight patients (73%) and severe degenerative arthritis in three patients (27%). The mean ADI in the bilateral group was 2.09 mm in the immediate postoperative period and 1.75 mm in 12-months postoperatively. The mean ADI in the unilateral group was 1.82 mm in the immediate postoperative period and 1.91 mm in 12-months postoperatively. Comparison of ADI measurements showed no significant differences in either group (p=0.893), and the fusion rate was 100% in both groups. Conclusion : Although bilateral C1LM-C2P is effective for AAI from a biomechanical perspective, unilateral screw fixation is a useful alternative in patients with anatomical variations.
Purpose: We conducted this study to examine the clinical results of the proximal metatarsal wedge osteotomy using a single screw fixation and the distal soft tissue procedure in patients with moderate to severe hallux valgus deformity. Materials and Methods: Between February 2002 and February 2004, we performed these procedures on 12 patients (15 cases). The 6 cases of all patients had mild to moderate instability in the first MTC (metatarsocuneiform) joint. We estimated the clinical outcomes, the radiological findings and complications. Results: AOFAS score was improved from preoperative 41.5 points to 87.7 points lastly on average. The mean correction angle of HVA and IMA was $23.8^{\circ}$ and $6.6^{\circ}$, respectively. The mean position of tibial sesamoid was 2.67 before surgery and 0.87 after surgery. The mean shortening of the first metatarsal bone was 3.07 mm after surgery. There was no pain and complications on the first MTC joint except the breakage of screw in one case and instability of the first MTC joint was improved postoperatively. Conclusion: We obtained good clinical and radiographic outcomes in our series. So, proximal metatarsal wedge osteotomy using a single screw fixation and distal soft tissue procedure seems one of the good surgical treatments for moderate hallux valgus deformity.
Background: This study was performed to identify the incidence of screw in-type lateral anchor pull-out in patients older than 60 years who underwent rotator cuff repair for large to massive rotator cuff tear (RCT). Methods: We reviewed 25 patients over 60 who were diagnosed with large to massive RCT and underwent arthroscopic rotator cuff repair in our hospital from March 2017 to February 2021. Preoperative tear size (anterior to posterior, medial to lateral) was measured via preoperative magnetic resonance imaging (MRI). All 25 patients underwent MRI scanning on postoperative day 1 and at 3 months after surgery. The change of anchor position was measured in axial views on MRI images postoperative day 1 and 3 months after surgery. And it was statistically compared according to bone mineral density (BMD), sex, and number of lateral anchors. Results: Two MRIs (postoperative day 1 and 3 months) in 25 patients were compared. Anchor pull-out occurred in six patients during 3 months (6.7%), and the mean pull-out length difference was 1.56 mm (range, 0.16-2.58 mm). There was no significant difference in the number of pull-out anchors, degree of pull-out difference by comparing BMD (A, BMD≤-2.5; B, BMD>-2.5), sex, or number of anchors used in each surgery (C, two anchors; D, three anchors) (p>0.05). Conclusions: Pull-out of screw in-type anchors was rarely observed and the mean pull-out length difference was negligibly small in our study. The screw in-type lateral anchor seems to be a decent option without concern of anchor pull-out even in elderly patients.
Kim, Bum-Joon;Kim, Se-Hoon;Lee, Haebin;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
Journal of Korean Neurosurgical Society
/
제60권2호
/
pp.225-231
/
2017
Objective : Solid bone fusion is an essential process in spinal stabilization surgery. Recently, as several minimally invasive spinal surgeries have developed, a need of artificial bone substitutes such as demineralized bone matrix (DBM), has arisen. We investigated the in vivo bone growth rate of DBM as a bone void filler compared to a local autologous bone grafts. Methods : From April 2014 to August 2015, 20 patients with a one or two-level spinal stenosis were included. A posterior lumbar interbody fusion using two cages and pedicle screw fixation was performed for every patient, and each cage was packed with autologous local bone and DBM. Clinical outcomes were assessed using the Numeric Rating Scale (NRS) of leg pain and back pain and the Korean Oswestry Disability Index (K-ODI). Clinical outcome parameters and range of motion (ROM) of the operated level were collected preoperatively and at 3 months, 6 months, and 1 year postoperatively. Computed tomography was performed 1 year after fusion surgery and bone growth of the autologous bone grafts and DBM were analyzed by ImageJ software. Results : Eighteen patients completed 1 year of follow-up, including 10 men and 8 women, and the mean age was 56.4 (32-71). The operated level ranged from L3/4 to L5/S1. Eleven patients had single level and 7 patients had two-level repairs. The mean back pain NRS improved from 4.61 to 2.78 (p=0.003) and the leg pain NRS improved from 6.89 to 2.39 (p<0.001). The mean K-ODI score also improved from 27.33 to 13.83 (p<0.001). The ROM decreased below 2.0 degrees at the 3-month assessment, and remained less than 2 degrees through the 1 year postoperative assessment. Every local autologous bone graft and DBM packed cage showed bone bridge formation. On the quantitative analysis of bone growth, the autologous bone grafts showed significantly higher bone growth compared to DBM on both coronal and sagittal images (p<0.001 and p=0.028, respectively). Osteoporotic patients showed less bone growth on sagittal images. Conclusion : Though DBM alone can induce favorable bone bridging in lumbar interbody fusion, it is still inferior to autologous bone grafts. Therefore, DBM is recommended as a bone graft extender rather than bone void filler, particularly in patients with osteoporosis.
Objective : The authors performed a retrospective study to assess the clinical and radiological outcome in symptomatic lumbar spondylolysis patients who underwent a direct pars repair surgery using two different surgical methods; pedicle screw with universal hook system (PSUH) and direct pars screw fixation (DPSF), and compared the results between two different treated groups. Methods : Forty-seven consecutive patients (PSUH; 23, DPSF; 15) with symptomatic lumbar spondylolysis who underwent a direct pars repair surgery were included. The average follow-up period was 37 months in the PSUH group, and 28 months in the DPSF group. The clinical outcome was measured using visual analogue pain scale (VAS) and Oswestry disability index (ODI). The length of operation time, the amount of blood loss, the duration of hospital stay, surgical complications, and fusion status were also assessed. Results : When compared to the DPSF group, the average preoperative VAS and ODI score of the PSUH group were less decreased at the last follow-up; (the PSUH group; back VAS : 4.9 vs. 3.0, leg VAS : 6.8 vs. 2.2, ODI : 50.6% vs. 24.6%, the DPSF group; back VAS : 5.7 vs. 1.1, leg VAS : 6.1 vs. 1.2, ODI : 57.4% vs. 18.2%). The average operation time was 174.9 minutes in the PSUH group, and 141.7 minutes in the DPSF group. The average blood loss during operation was 468.8 cc in the PSUH group, and 298.8 cc in the DPSF group. The average hospital stay after operation was 8.9 days in the PSUH group, and 7 days in the DPSF group. In the PSUH group, there was one case of a screw misplacement requiring revision surgery. In the DPSF group, one patient suffered from transient leg pain. The successful bone fusion rate was 78.3% in the PSUH group, and 93.3% in the DPSF group. Conclusion : The present study suggests that the technique using direct pars screw would be more effective than the method using pedicle screw with lamina hook system, in terms of decreased operation time, amount of blood loss, hospital stay, and increased fusion success rate, as well as better clinical outcome.
교정용 미니스크류의 원추 형태가 식립 후 시기별 안정성에 미치는 영향을 알아보기 위해, 시기별 제거 토오크 및 동요도와 조직시편분석을 시행하였다. 성견 6마리의 하악 협측골에 원통형과 원추형 교정용 미니스크류 (Biomaterials Korea, Seoul, Korea) 48개를 식립하고, 식립 시 식립 토오크와 동요도를 측정하고 3주, 12주 동안 교정력을 부여한 후, 제거 시 제거 토오크와 동요도를 측정하였다. 식립 토오크는 원통형 미니스크류에서 13.6 Ncm, 원추형 미니스크류에서 22.3 Ncm 로 원추형 미니스크류에서 높은 식립 토오크가 측정되었다 (p < 0.001). 식립 3주째 제거 토오크는 원통형 미니스크류에서 5.7 Ncm, 원추형 미니스크류에서 9.1 Ncm 로 유의한 차이가 관찰되었다 (p < 0.05). 식립 12주째 원추형 미니스크류의 제거 토오크는 3.6 Ncm 로 유의하게 감소하여 (p < 0.05) 원통형 미니 스크류의 4.2 Ncm 와 유의한 차이를 보이지 않았다. 이상의 결과로 미니스크류의 원추 구조는 식립 토오크를 유의하게 증가시켜 식립 후 3주간 안정성에 도움이 되었으나, 12주 후 안정성에 있어서는 원통형 미니스크류와 유사하였음을 시사한다.
Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
Journal of Periodontal and Implant Science
/
제48권4호
/
pp.202-212
/
2018
Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.
This study was designed to investigate the peri-implant tissue reaction in ovariectomized osteoporotic female rats, and to evaluate effects of estrogen, calcitonin, parathyroid hormone on the bone - implant interface in osteoporotic rats. 120 Sprague - Dawley rats were used in this experiments. Osteoporosis was induced by bilateral ovariectomy. They were divided 5 groups : sham-operated control group(Sham), ovariectomized group (OVX), OVX and estrogen treated group (OVX+E), OVX and PTH treated group (OVX+PTH), and OVX and calcitonin treated group (OVX+CT). Eight weeks after ovariectomy, two titanium screw implants were inserted into the left tibia of each rat. Eight weeks after the insertion of the implants, the periotest values (PTV) of implant were examined, and the rats were sacrificed, and examined the reaction of bone tissue surrounding the implant both histologically and histomorphometrically. The bone density and ash weight of opposite right tibia were examined. Over 40 rats were fractured on left tibia that was implant inserted. On histologically finding, all groups were osseointegrated well, especially in OVX+PTH group. In OVX group, tibial cortical bone showed many large harversian canal and microfracture lines. The OVX+PTH group showed the lowest mean PTV (-2.33) (p<0.05), and the hightest mean bone - implant contact percentage (89%) (p>0.05). But the OVX+CT group showed the highest mean bone density ($5.45mg/cm^3$) and ash weight (56.12%) (p<0.05). The results indicate that PTH treatment enhances osseointegration of implant in OVX rats, and CT treatment depresses bone turnover and prevent the development of osteopenia in OVX rats.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.