The Effect of Postoperative Use of Teriparatide Reducing Screw Loosening in Osteoporotic Patients

  • Kim, Jae Wook;Park, Seung Won;Kim, Young Baeg;Ko, Myeong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권4호
    • /
    • pp.494-502
    • /
    • 2018
  • Objective : The loosening of pedicle screws (PS) is one of the frequent problems of spinal surgery in the patients with osteoporosis. Previous studies had revealed that intermittent injection of teriparatide could reduce PS loosening by improving bone mass and quality when their patients took parathyroid hormone for a considerable duration before surgery. However, although the teriparatide is usually used after spine surgery in most clinical situations, there was no report on the efficacy of teriparatide treatment started after spine surgery. The purpose of this retrospective study was to examine the efficacy of teriparatide treatment started immediately after lumbar spinal surgery to prevent pedicle screw loosening in patients with osteoporosis. Methods : We included 84 patients with osteoporosis and degenerative lumbar disease who underwent transforaminal interbody fusion and PS fixation and received parathyroid hormone or bisphosphonate (BP) postoperatively. They were divided into teriparatide group (daily injection of $20{\mu}g$ of teriparatide for 6 months, 33 patients, 172 screws) and BP group (weekly oral administration of 35 mg of risedronate, 51 patients, 262 screws). Both groups received calcium (500 mg/day) and cholecalciferol (1000 IU/day) together. The screw loosening was evaluated with simple radiographic exams at 6 and 12 months after the surgery. We counted the number of patients with PS loosening and the number of loosened PS, and compared them between the two groups. Clinical outcomes were evaluated using visual analog scale (VAS) and Oswestry disability index (ODI) preoperatively, and at 12 months after surgery. Results : There was no significant difference in the age, sex, diabetes, smoking, bone mineral density, body mass index, and the number of fusion levels between the two groups. The number of PS loosening within 6 months after surgery did not show a significant difference between the teriparatide group (6.9%, 12/172) and the BP group (6.8%, 18/272). However, during 6-12 months after surgery, it was significantly lower in the teriparatide group (2.3%, 4/172) than the BP group (9.2%, 24/272) (p<0.05). There was no significant difference in the number of patients showing PS loosening between the teriparatide and BP groups. The teriparatide group showed a significantly higher degree of improvement of the bone mineral density (T-score) than that of BP group (p<0.05). There was no significant difference in the pre- and post-operative VAS and ODI between the groups. Conclusion : Our data suggest that the teriparatide treatment starting immediately after lumbar spinal fusion surgery could reduce PS loosening compared to BP.

IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구 (FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY)

  • 김병옥;홍국선;김수관
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권4호
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method

  • Paik, Seung-Chull;Chun, Hyoung-Joon;Bak, Koang Hum;Ryu, Jeil;Choi, Kyu-Sun
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권6호
    • /
    • pp.460-464
    • /
    • 2015
  • Objective : Bilateral C1 lateral mass and C2 pedicle screw fixation (C1LM-C2P) is an ideal technique for correcting atlantoaxial instability (AAI). However, the inevitable situation of vertebral artery injury or unfavorable bone structure may necessitate the use of unilateral C1LM-C2P. This study compares the fusion rates of the C1 lateral mass and C2 pedicle screw in the unilateral and bilateral methods. Methods : Over five years, C1LM-C2P was performed in 25 patients with AAI in our institute. Preoperative studies including cervical X-ray, three-dimensional computed tomography (CT), CT angiogram, and magnetic resonance imaging were performed. To evaluate bony fusion, measurements of the atlanto-dental interval (ADI) and CT scans were performed in the preoperative period, immediate postoperative period, and postoperatively at 1, 3, 6, and 12 months. Results : Unilateral C1LM-C2P was performed in 11 patients (44%). The need to perform unilateral C1LM-C2P was due to anomalous course of the vertebral artery in eight patients (73%) and severe degenerative arthritis in three patients (27%). The mean ADI in the bilateral group was 2.09 mm in the immediate postoperative period and 1.75 mm in 12-months postoperatively. The mean ADI in the unilateral group was 1.82 mm in the immediate postoperative period and 1.91 mm in 12-months postoperatively. Comparison of ADI measurements showed no significant differences in either group (p=0.893), and the fusion rate was 100% in both groups. Conclusion : Although bilateral C1LM-C2P is effective for AAI from a biomechanical perspective, unilateral screw fixation is a useful alternative in patients with anatomical variations.

무지 외반증의 치료에서 단일 나사못을 이용한 근위 중족골 쐐기 절골술 (Proximal Metatarsal Wedge Osteotomy with Single Screw Fixation in Treatment of Hallux Valgus)

  • 최재열;신헌규;장일성;강동호
    • 대한족부족관절학회지
    • /
    • 제9권1호
    • /
    • pp.87-93
    • /
    • 2005
  • Purpose: We conducted this study to examine the clinical results of the proximal metatarsal wedge osteotomy using a single screw fixation and the distal soft tissue procedure in patients with moderate to severe hallux valgus deformity. Materials and Methods: Between February 2002 and February 2004, we performed these procedures on 12 patients (15 cases). The 6 cases of all patients had mild to moderate instability in the first MTC (metatarsocuneiform) joint. We estimated the clinical outcomes, the radiological findings and complications. Results: AOFAS score was improved from preoperative 41.5 points to 87.7 points lastly on average. The mean correction angle of HVA and IMA was $23.8^{\circ}$ and $6.6^{\circ}$, respectively. The mean position of tibial sesamoid was 2.67 before surgery and 0.87 after surgery. The mean shortening of the first metatarsal bone was 3.07 mm after surgery. There was no pain and complications on the first MTC joint except the breakage of screw in one case and instability of the first MTC joint was improved postoperatively. Conclusion: We obtained good clinical and radiographic outcomes in our series. So, proximal metatarsal wedge osteotomy using a single screw fixation and distal soft tissue procedure seems one of the good surgical treatments for moderate hallux valgus deformity.

  • PDF

Magnetic resonance imaging analysis of screw in-type lateral anchor pull-out in large to massive rotator cuff repair in patients older than 60 years

  • Lee, Sang-Yoon;Noh, Young-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제25권1호
    • /
    • pp.15-21
    • /
    • 2022
  • Background: This study was performed to identify the incidence of screw in-type lateral anchor pull-out in patients older than 60 years who underwent rotator cuff repair for large to massive rotator cuff tear (RCT). Methods: We reviewed 25 patients over 60 who were diagnosed with large to massive RCT and underwent arthroscopic rotator cuff repair in our hospital from March 2017 to February 2021. Preoperative tear size (anterior to posterior, medial to lateral) was measured via preoperative magnetic resonance imaging (MRI). All 25 patients underwent MRI scanning on postoperative day 1 and at 3 months after surgery. The change of anchor position was measured in axial views on MRI images postoperative day 1 and 3 months after surgery. And it was statistically compared according to bone mineral density (BMD), sex, and number of lateral anchors. Results: Two MRIs (postoperative day 1 and 3 months) in 25 patients were compared. Anchor pull-out occurred in six patients during 3 months (6.7%), and the mean pull-out length difference was 1.56 mm (range, 0.16-2.58 mm). There was no significant difference in the number of pull-out anchors, degree of pull-out difference by comparing BMD (A, BMD≤-2.5; B, BMD>-2.5), sex, or number of anchors used in each surgery (C, two anchors; D, three anchors) (p>0.05). Conclusions: Pull-out of screw in-type anchors was rarely observed and the mean pull-out length difference was negligibly small in our study. The screw in-type lateral anchor seems to be a decent option without concern of anchor pull-out even in elderly patients.

Demineralized Bone Matrix (DBM) as a Bone Void Filler in Lumbar Interbody Fusion : A Prospective Pilot Study of Simultaneous DBM and Autologous Bone Grafts

  • Kim, Bum-Joon;Kim, Se-Hoon;Lee, Haebin;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.225-231
    • /
    • 2017
  • Objective : Solid bone fusion is an essential process in spinal stabilization surgery. Recently, as several minimally invasive spinal surgeries have developed, a need of artificial bone substitutes such as demineralized bone matrix (DBM), has arisen. We investigated the in vivo bone growth rate of DBM as a bone void filler compared to a local autologous bone grafts. Methods : From April 2014 to August 2015, 20 patients with a one or two-level spinal stenosis were included. A posterior lumbar interbody fusion using two cages and pedicle screw fixation was performed for every patient, and each cage was packed with autologous local bone and DBM. Clinical outcomes were assessed using the Numeric Rating Scale (NRS) of leg pain and back pain and the Korean Oswestry Disability Index (K-ODI). Clinical outcome parameters and range of motion (ROM) of the operated level were collected preoperatively and at 3 months, 6 months, and 1 year postoperatively. Computed tomography was performed 1 year after fusion surgery and bone growth of the autologous bone grafts and DBM were analyzed by ImageJ software. Results : Eighteen patients completed 1 year of follow-up, including 10 men and 8 women, and the mean age was 56.4 (32-71). The operated level ranged from L3/4 to L5/S1. Eleven patients had single level and 7 patients had two-level repairs. The mean back pain NRS improved from 4.61 to 2.78 (p=0.003) and the leg pain NRS improved from 6.89 to 2.39 (p<0.001). The mean K-ODI score also improved from 27.33 to 13.83 (p<0.001). The ROM decreased below 2.0 degrees at the 3-month assessment, and remained less than 2 degrees through the 1 year postoperative assessment. Every local autologous bone graft and DBM packed cage showed bone bridge formation. On the quantitative analysis of bone growth, the autologous bone grafts showed significantly higher bone growth compared to DBM on both coronal and sagittal images (p<0.001 and p=0.028, respectively). Osteoporotic patients showed less bone growth on sagittal images. Conclusion : Though DBM alone can induce favorable bone bridging in lumbar interbody fusion, it is still inferior to autologous bone grafts. Therefore, DBM is recommended as a bone graft extender rather than bone void filler, particularly in patients with osteoporosis.

Direct Pars Repair Surgery Using Two Different Surgical Methods : Pedicle Screw with Universal Hook System and Direct Pars Screw Fixation in Symptomatic Lumbar Spondylosis Patients

  • Shin, Myung-Hoon;Ryu, Kyeong-Sik;Rathi, Nitesh Kumar;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권1호
    • /
    • pp.14-19
    • /
    • 2012
  • Objective : The authors performed a retrospective study to assess the clinical and radiological outcome in symptomatic lumbar spondylolysis patients who underwent a direct pars repair surgery using two different surgical methods; pedicle screw with universal hook system (PSUH) and direct pars screw fixation (DPSF), and compared the results between two different treated groups. Methods : Forty-seven consecutive patients (PSUH; 23, DPSF; 15) with symptomatic lumbar spondylolysis who underwent a direct pars repair surgery were included. The average follow-up period was 37 months in the PSUH group, and 28 months in the DPSF group. The clinical outcome was measured using visual analogue pain scale (VAS) and Oswestry disability index (ODI). The length of operation time, the amount of blood loss, the duration of hospital stay, surgical complications, and fusion status were also assessed. Results : When compared to the DPSF group, the average preoperative VAS and ODI score of the PSUH group were less decreased at the last follow-up; (the PSUH group; back VAS : 4.9 vs. 3.0, leg VAS : 6.8 vs. 2.2, ODI : 50.6% vs. 24.6%, the DPSF group; back VAS : 5.7 vs. 1.1, leg VAS : 6.1 vs. 1.2, ODI : 57.4% vs. 18.2%). The average operation time was 174.9 minutes in the PSUH group, and 141.7 minutes in the DPSF group. The average blood loss during operation was 468.8 cc in the PSUH group, and 298.8 cc in the DPSF group. The average hospital stay after operation was 8.9 days in the PSUH group, and 7 days in the DPSF group. In the PSUH group, there was one case of a screw misplacement requiring revision surgery. In the DPSF group, one patient suffered from transient leg pain. The successful bone fusion rate was 78.3% in the PSUH group, and 93.3% in the DPSF group. Conclusion : The present study suggests that the technique using direct pars screw would be more effective than the method using pedicle screw with lamina hook system, in terms of decreased operation time, amount of blood loss, hospital stay, and increased fusion success rate, as well as better clinical outcome.

교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크 (Insertion and removal torques according to orthodontic mini-screw design)

  • 차정열;윤태민;황충주
    • 대한치과교정학회지
    • /
    • 제38권1호
    • /
    • pp.5-12
    • /
    • 2008
  • 교정용 미니스크류의 원추 형태가 식립 후 시기별 안정성에 미치는 영향을 알아보기 위해, 시기별 제거 토오크 및 동요도와 조직시편분석을 시행하였다. 성견 6마리의 하악 협측골에 원통형과 원추형 교정용 미니스크류 (Biomaterials Korea, Seoul, Korea) 48개를 식립하고, 식립 시 식립 토오크와 동요도를 측정하고 3주, 12주 동안 교정력을 부여한 후, 제거 시 제거 토오크와 동요도를 측정하였다. 식립 토오크는 원통형 미니스크류에서 13.6 Ncm, 원추형 미니스크류에서 22.3 Ncm 로 원추형 미니스크류에서 높은 식립 토오크가 측정되었다 (p < 0.001). 식립 3주째 제거 토오크는 원통형 미니스크류에서 5.7 Ncm, 원추형 미니스크류에서 9.1 Ncm 로 유의한 차이가 관찰되었다 (p < 0.05). 식립 12주째 원추형 미니스크류의 제거 토오크는 3.6 Ncm 로 유의하게 감소하여 (p < 0.05) 원통형 미니 스크류의 4.2 Ncm 와 유의한 차이를 보이지 않았다. 이상의 결과로 미니스크류의 원추 구조는 식립 토오크를 유의하게 증가시켜 식립 후 3주간 안정성에 도움이 되었으나, 12주 후 안정성에 있어서는 원통형 미니스크류와 유사하였음을 시사한다.

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • 제48권4호
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

난소절제로 유도된 골다공증 흰쥐에서 implant 주위 조직 반응에 관한 실험적 연구 (EXPERIMENTAL STUDY OF PERI-IMPLANT TISSUE REACTION IN OVARIECTOMIZED OSTEOPOROTIC RATS)

  • 조인호;김종여;박수성;박종섭;임헌송
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.183-198
    • /
    • 1998
  • This study was designed to investigate the peri-implant tissue reaction in ovariectomized osteoporotic female rats, and to evaluate effects of estrogen, calcitonin, parathyroid hormone on the bone - implant interface in osteoporotic rats. 120 Sprague - Dawley rats were used in this experiments. Osteoporosis was induced by bilateral ovariectomy. They were divided 5 groups : sham-operated control group(Sham), ovariectomized group (OVX), OVX and estrogen treated group (OVX+E), OVX and PTH treated group (OVX+PTH), and OVX and calcitonin treated group (OVX+CT). Eight weeks after ovariectomy, two titanium screw implants were inserted into the left tibia of each rat. Eight weeks after the insertion of the implants, the periotest values (PTV) of implant were examined, and the rats were sacrificed, and examined the reaction of bone tissue surrounding the implant both histologically and histomorphometrically. The bone density and ash weight of opposite right tibia were examined. Over 40 rats were fractured on left tibia that was implant inserted. On histologically finding, all groups were osseointegrated well, especially in OVX+PTH group. In OVX group, tibial cortical bone showed many large harversian canal and microfracture lines. The OVX+PTH group showed the lowest mean PTV (-2.33) (p<0.05), and the hightest mean bone - implant contact percentage (89%) (p>0.05). But the OVX+CT group showed the highest mean bone density ($5.45mg/cm^3$) and ash weight (56.12%) (p<0.05). The results indicate that PTH treatment enhances osseointegration of implant in OVX rats, and CT treatment depresses bone turnover and prevent the development of osteopenia in OVX rats.

  • PDF