• Title/Summary/Keyword: Bone plate

Search Result 557, Processing Time 0.03 seconds

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.6
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

Design and stress analysis of femur bone implant with composite plates

  • Ramakrishna, S.;Pavani, B.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.5 no.1
    • /
    • pp.37-50
    • /
    • 2020
  • Development of lightweight implant plates are important to reduce the stress shielding effect for a prosthesis of femur bone fractures. Stainless steel (SS-316L) is a widely used material for making implants. Stress shielding effect and other issues arise due to the difference in mechanical properties of stainless steel when compared with bone. To overcome these issues, composite materials seem to be a better alternative solution. The comparison is made between two biocompatible composite materials, namely Ti-hydroxyapatite and Ti-polypropylene. "Titanium (Ti)" is fiber material while "hydroxyapatite" and "polypropylene" are matrix materials. These two composites have Young's modulus closer to the bone than stainless steel. Besides the variety of bones, present paper constrained to femur bone analysis only. Being heaviest and longest, the femur is the most likely to fail among all bone failures in human. Modelling of the femur bone, screws, implant and assembly was carried out using CATIA and static analysis was carried out using ANSYS. The femur bone assembly was analyzed for forces during daily activities. Ti-hydroxyapatite and Ti-polypropylene composite implants induced more stress in composite implant plate, results less stress induced in bone leading to a reduction in shielding effect than stainless steel implant plate thus ensuring safety and quick healing for the patient.

Absorbable Plate-Related Infection after Facial Bone Fracture Reduction

  • Choi, Seung Hyup;Lee, Jang Hyun
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.1-4
    • /
    • 2016
  • Absorbable plates are used widely for fixation of facial bone fractures. Compared to conventional titanium plating systems, absorbable plates have many favorable traits. They are not palpable after plate absorption, which obviates the need for plate removal. Absorbable plate-related infections are relatively uncommon at less than 5% of patients undergoing fixation of facial bone fractures. The plates are made from a mixture of poly-L-lactic acid and poly-DL-lactic acid or poly-DL-lactic acid and polyglycolic acid, and the ratio of these biodegradable polymers is used to control the longevity of the plates. Degradation rate of absorbable plate is closely related to the chance of infection. Low degradation is associated with increased accumulation of plate debris, which in turn can increase the chance of infection. Predisposing factors for absorbable plate-related infection include the presence of maxillary sinusitis, plate proximity to incision site, and use of tobacco and significant amount of alcohol. Using short screws in fixating maxillary fracture accompanied maxillary sinusitis will increase the rate of infection. Avoiding fixating plates near the incision site will also minimize infection. Close observation until complete absorption of the plate is crucial, especially those who are smokers or heavy alcoholics. The management of plate infection is varied depending on the clinical situation. Severe infections require plate removal. Wound culture and radiologic exam are essential in treatment planning.

CT Observation of Alloplastic Materials Used in Blow Out Fracture (안와골절 정복술에 사용된 인공삽입물의 전산화단층촬영 추적관찰)

  • Lee, Won;Kang, Dong-Hee
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.380-384
    • /
    • 2010
  • Purpose: Distinguishing different types of implants and assessing the position and size of implants by radiologic exam after orbital wall reconstruction is important in determining the surgery outcome and forecasting prognosis. We observed time-dependent density changes in three types of implants (porous polyethylene, resorbing plate and titanium mesh plate) by performing facial bone CT after orbital wall reconstructions. Methods: A total of 32 patients, who had underwent orbital wall fracture surgery from October 2006 to March 2009 and received facial bone CT as outpatients at 1 postoperative year were included in the study. Follow-up facial bone CT was performed on the patients pre- operatively, 1 month post-operatively, and 1 year post-operatively to observe the status of the orbital implants. Medpor $^{(R)}$ (Porex Surgical, Inc., Newnan, Ga.) was used as porous polyethylene and followed-up in 14 cases; for resorbing plate, Synthes mesh plate (Synthes, Oberdorf, Switzerland) was used in the reconstruction, and followed-up in 11 cases; and titanium mesh plate usage was followed-up in 7 cases. Computed tomographic scan (CT) and water's view were done for radiography, and hounsfield unit (HU) was used to compare density of those facial bone CT. Wilcoxon signed rank test was applied to statistically verify measurement difference in each group of hounsfield units. Results: Facial bone CT examination performed in 1 month post-operative showed that the density of porous polyethylene, resorbing plate and titanium mesh plate were -42.07, 105.67 and 539.48 on average, respectively. Among the three types of implants, titanium mesh plate showed the highest density due to its radiopaque feature. Following up the density of three types of implants in CT during 1 year after the orbital wall fracture surgery, the density of porous polyethylene increased in 10.52 House Field Units and the resorbing plate was decreased in 26.87 HouseField Units. There were no significant differences between densities in 1 month post-operatively and 1 year post-operatively in each group ($p{\geq}0.05$). Conclusion: We performed facial bone CT on patients with orbital fractures during follow-up period, distinguishing the types of implants by the different concentration of implant density, and the densities showed little change even at 1 year post-operative. To observe how implant densities change in facial bone CT, further studies with longer follow-up periods should be carried out.

Effects of Herbal Composition and Fermented Cervi Pantotrichum Cornu on Longitudinal Bone Growth in Adolescent Male Rats (한약혼합제제(韓藥混合製劑)와 녹용발효추출물(鹿茸醱酵抽出物)의 성장기(成長期) 흰쥐 장골(長骨) 길이 성장(成長)에 대한 효과)

  • Lee, Se-Na;Son, Jae-Bong;Sohn, Jong-Hee;Kim, Wan-Ki;Lee, Sang-Jun;Lee, Pyeong-Jae;Leem, Kang-Hyun
    • The Korea Journal of Herbology
    • /
    • v.24 no.1
    • /
    • pp.121-131
    • /
    • 2009
  • Objectives:This study was designed to investigate the effects of herbal composition and fermented Cervi Pantotrichum Cornu on the growth of longitudinal bone in the adolescent male rats. Methods: Longitudinal bone growth was measured by fluorescence microscopy. To examine the effects on the growth plate metabolism, the total height of growth plate and the induction of local insulin-like growth factor-1 (IGF-1) and bone morphogenetic protein-2 (BMP-2) were measured. Results: The herbal composition treatment enhanced longitudinal bone growth and total heght of growth plate and promoted the induction of local IGF-1 and BMP-2 of growth plate. Conclusions: This study showed that the herbal composition have the effect of bone growth in adolescent rats and might be used for the growth delayed adolescent and inherent growth failure patient.

Effects of Cheunggyeongsamul-tang Extract on Longitudinal Bone Growth in Adolescent Female Rats (청경사물탕(淸經四物湯) 추출물의 성장기 흰쥐 장골길이 성장에 대한 효과)

  • Lee, Jung-Hun;Lee, Se-Na;Son, Jae-Bong;Keum, So-Hyun;Leem, Kang-Hyun
    • The Korea Journal of Herbology
    • /
    • v.24 no.4
    • /
    • pp.149-157
    • /
    • 2009
  • Objectives : This study was designed to investigate the effects of Cheunggyeongsamul-tang extract on the growth of longitudinal bone in adolescent female rats. Methods : Longitudinal bone growth was measured by fluorescent microscopy. To examine the effects on the growth plate metabolism, the total height of growth plate, the induction of local insulin-like growth factor-1 (IGF-1), IGF-1 receptor, bone morphogenetic protein-2 (BMP-2), BMPR-1A, indian hedgehog (IHH), and parathyroid hormone-related protein (PTH-rP) were measured. Results : Cheunggyeongsamul-tang extract enhanced longitudinal bone growth and total height of the growth plate. Also, it promoted the induction of local IGF-1, BMP-2, IHH and PTH-rP of the growth plate. Conclusions : This study shows that the Cheunggyeongsamul-tang extract effects longitudinal bone growth in adolescent rats and might be used for both stunted adolescents and inherent growth failure patients.

New Multi-herb Mixture, HT005, Induces Longitudinal Bone Growth in Male Rats (신한약복합물 HT005의 성장기 흰쥐 장골길이 성장에 미치는 효과)

  • Kim, Mi-Yeon;Ramirez, Marcus J.;Lee, Dong-Hun;Lim, Dong-Wook;Choi, Ho-Young;Kim, Ho-Cheol
    • The Korea Journal of Herbology
    • /
    • v.25 no.1
    • /
    • pp.75-81
    • /
    • 2010
  • Objectives : It was investigated new herbal prescription HT005 supported by traditional Korean medicine has a activity on the longitudinal bone growth of rats. HT005 were consisted of the root of Angelica sinensis, the fruit of Alpinia oxyphylla, the root of Astragalus membranaceus, the stem of Eleutherococcus senticosus, and the root of Dioscorea japonica, and Poria cocos. Method : To investigate the effect on longitudinal bone growth in adolescent male Sprague-Dawley rats, the longitudinal length of growth plate was measured directly by the tetracycline fluorescent labeling method and chondrocyte staining method. HT005 administered orally for four days, and the tetracycline was injected twice on the growth plate of the animals for fluorescent dying. The rate of longitudinal bone growth was measured the length between the tetracycline bands which fixed on the 3rd day and 5th day after injection. Cresyl violet was also used to stain the chondrocytes in the growth plate. The length of growth plate after administration was compared. Expression of IGF-1 and BMP-2 in the growth plate was investigated by immunohistochemistry. Results : HT005 showed a significant longitudinal bone growth which was $301.0{\pm}6.1\;{\mu}m/day$ at the dose of 100 mg/kg and $283.8{\pm}1.25\;{\mu}m/day$ (p < 0.001)at the dose of 10 mg/kg of HT005, compared to control group by the tetracycline fluorescent labeling method. HT005 showed a significant chondrocyte length on growth plate which was measured $797.19{\pm}3.31\;{\mu}m$ (p < 0.001) at the dose of 100 mg/kg and $720.14{\pm}2.19$ (p < 0.001) ${\mu}m$ at the dose of 10 mg/kg compared to the control group by cresyl-violet staining method. Both the number and intensity of BMP-2 and IGF-1 positive cells were increased in the hypertrophic zone of growth plate. There was a significant correlation between BMP-2 and IGF-1 expression and heights of chondrocytes in growth plate. Conclusions : Treatment of HT005 on Sprague-Dawley rats markedly increased the longitudinal bone growth. Therefore, HT005 may be an alternative herbal source to growth hormone as it promotes bone growth in children afflicted by growth retardation.

A SUTDY ABOUT THE SHAPE OF THE FRAMEWORK OF THE FIXED BONE ANCHORED BRIDGE USING DENIAL IMPLANTS (임프란트를 이용한 고정성 계속가공의치의 FRAMEWORK 형태에 관한 연구)

  • Kim, Te-Gyun;Lee, Young-Soo;Yoo, Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.104-119
    • /
    • 1998
  • The purpose of this study was pertinent design of the framework of the fixed bone anchored bridge using implants in the edentulous mandible through analysis of stress distribution by the three dimensional finite element analysis method. The results were as follows: 1. The L-shaped framework was favorable in restoring the edentulous mandible by implants and fixed bone anchored bridge. 2. The structure of the framework should be designed to endure the occlusal load because of stress concentration at the most distal abutment of the framework. 3. The stress at the distal implant where cantilever starts was twice as much as that of other portions. 4. Compressive stress was generated on the framework of the mesial side of the distal implant and extrusive force was induced to the mesially positioned implants. 5. The height of vertical plate was high as possible as can be to distribute stresses concentrating bucco-lingually and labio-lingually in the framework between abutments, 6. Reinforcement of the horizontal plate thickness was needed because stress was loaded more on the horizontal plate than on the vertical plate of the framework. 7. Lengthening of the vertical plate can compensate for any limitations in horizontal plate width.

  • PDF

Internal Fixation with Plate and Bone Graft of Mid-shaft Clavicle Nonunion (쇄골 간부 불유합의 자가골 이식술 및 금속판 내고정술)

  • Ko Sang-Hun;Cho Sung-Do;Park Moon-Soo;Woo Jong-Ken;Lee Chae-Chil;Jeong Ji-Young;Jung Kwang-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.1
    • /
    • pp.19-22
    • /
    • 2005
  • Purpose: The causes of twelve cases of the mid-shaft clavicle nonunion and the results of internal fixation with plate and bone graft were investigated. Materials and method: From August 1997 to March 2003, twelve cases of the mid-shaft clavicle nonunion were operated with internal fixation with plate and bone graft. The duration of follow-up was average 13 months. Results: The causes of the mid-shaft clavicle nonunion included severe associated injury, severe initial displacement of the fracture fragments and insecure fixation. All cases were operated with internal fixation with plate and bone graft. According to the factor for evaluations of results, using a rating scale of excellent (no apparent factors), good (one factor), fair (two factors), poor (more than three factors), the results showed 10 excellent, 1 good and 1 poor. Screw loosening was developed in only one case . Conclusion: The internal fixation with plate and bone graft of the mid-shaft clavicle nonunion after failed conservative treatment achieved excellent results and seemed to be the procedure of choice for mid-shaft clavicle nonunion.