• 제목/요약/키워드: Bone contact

검색결과 384건 처리시간 0.026초

The effect of fibronectin-coated implant on canine osseointegration

  • Kim, Sung-Tae;Myung, Woo-Chun;Lee, Jung-Seok;Cha, Jae-Kook;Jung, Ui-Won;Yang, Hyeong-Cheol;Lee, In-Seop;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.242-247
    • /
    • 2011
  • Purpose: The purpose of this study was to characterize the osseointegration of the fibronectin-coated implant surface. Methods: Sand-blasted, large-grit, acid-etched (SLA) surface implants, with or without a thin calcium phosphate and fibronectin coating, were placed in edentulous mandibles of dogs 8 weeks after extraction. All dogs were sacrificed forhistological and histomorphometric evaluation after 4- and 8-week healing periods. Results: All types of implants were clinically stable without any mobility. Although the bone-to-implant contact and bone density of the SLA implants coated with calcium phosphate (CaP)/fibronectin were lower than the uncoated SLA implants, there were no significant differences between the uncoated SLA surface group and the SLA surface coated with CaP/fibronectin group. Conclusions: Within the limits of this study, SLA surfaces coated with CaP/fibronectin were shown to have comparable bone-to-implant contact and bone density to uncoated SLA surfaces.

임플란트 생체금속들과 골조직간의 생체적합도에 관한 연구 (BICOMPATIBILITY OF BICOMTALS IN RABBIT BONE)

  • 한종현;허성주;정종평;구영;류인철;최용창
    • 대한치과보철학회지
    • /
    • 제35권3호
    • /
    • pp.557-565
    • /
    • 1997
  • Screw-shaped implants of commercially pure (c.p.) titanium, c.p. niobium, c.p. zirconium, and stainless steel(Sus 304) were inserted in the rabbit tibial bone over 12 weeks of follow-up. New developed torque gauge instrument was used to evaluate the implant holding power and a image analysis program coupled to a microscope was used for histomorphometry. The three best consecutive threads of each implant were measured. Quantitative analyses at 12 weeks revealed a partial bone contact to the four kinds investigated metals. There were no obvious adverse tissue reactions to any of the biomaterials. At 12 weeks the average removal torques for titanium, niobium and zirconium were better than that needed for Sus 304 screws, on the other hand high score of bony contact ratio of titanium and niobium were showed in comparison to those of zirconium and Sus 304. There was no significant differences in the amount of interfacial bone of zirconium and Sus 304 whereas there was significant difference in the torque forces of niobium and Sus 304. Three months after implant insertion, the average removal torque was 6.64 Ncm for the titanium, 6.57 Ncm for the niobium, 6.38 Ncm for the zirconium, and 4.25 Ncm for the Sus 304. On average bone contacts there were 51.24% in the titanium, 48.19% in the niobium, 31.79% in the zirconium, 23.54% in the Sus 304. Biocompatibility of the titanium, niobium and zirconium was acceptable level in comparison to the Sus 304.

  • PDF

식편압입의 발현에 관한 임상적 연구 (A CLINICAL STUDY ON THE OCCURRENCE OF FOOD IMPACTION)

  • 정재훈;오상천;동진근
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.50-58
    • /
    • 2000
  • The purpose of this study was to investigate the causes of food impaction and to explore solutions as well. For this study, 39 patients with food impaction were selected. 77 contact areas in these patients were investigated mobility, tightness of contact area, gingival index, plaque index, attachment loss, alveolar bone loss, proximal caries, marginal ridge distance and occlusal relationships. The results were as follows ; 1. Teeth without distal support were found to be the most frequent site of food impaction (41.6%). Food impaction was found to be more frequent in the upper teeth (65.2%) than the lower teeth (33.8%). 2. Food impaction was found in tight contact cases (71.4%). Alveolar bone loss was not found in the early stage of food impaction (83.1%) 3. The distance between the marginal ridges of food impaction sites (mean=0.48mm) was short-er than that of the control group. (mean=0.77mm) (p<0.001) 4. In 18.2% of the cases, proximal carries were found at the food impaction site. 5. Food impaction affected patient's occlusion with the following frequencies, cusp to marginal ridge relationship (72.7%), cusp to fossa relationship (3.9%) and stepped relationship (23.4%).

  • PDF

성견에서 표면처리된 교정용 마미크로 임플랜트의 골 접촉률 및 동요도 (Bone-implant contact and mobility of surface-fronted orthodontic micro-implants in dogs)

  • 박승현;김성훈;류준하;강윤구;정규림;국윤아
    • 대한치과교정학회지
    • /
    • 제38권6호
    • /
    • pp.416-426
    • /
    • 2008
  • 본 연구는 비글견에 식립된 sandblasted, large grit and acid-etched (SLA) 표면처리된 교정용 마이크로임플랜트와 평활면 마이크로임플랜트에 교정력을 가한 후 시간 경과에 따른 동요도와 골접촉률의 차이를 규명하기 위해 시행되었다. 비글 성견 네 마리를 이용하여 상, 하악 협측과 구개측 골에 대해 SLA 표면처리된 표면처리군 48개, 평활면의 비처리군 48개의 마이크로임 플랜트 96개를 식립하고 2주의 치유기간 후 교정력(150 - 200 g)을 지속적 으로 가했으며 식립 4주 후에 두 마리를 희생시키고, 12주 후에 나머지 2마리를 희생시켰다. 표면처리군과 비처리군 간의 마이크로 임플랜트의 동요도와 골과 임플랜트 간 접촉률을 조직학적인 측면에서 측정 비교하여 다음과 같은 결과를 얻었다. 상악 협측과 구개측에서는 표면처리군과 미처리군의 동요도에서 유의성 있는 차이가 없었으나 하악협측에서는 표면 처리군이 유의하게 안정적인 동요도를 보였다. 마이크로임플랜트와 인접골 간 접촉률은 상악 협측에서는 4주와 12주 모두 표면처리군과 미처리군 간에 유의 한 차이가 없었으나 하악 협측과 구개측의 경우 4주와 12주 모두 표면처리군이 비처리군에 비해 유의하게 높은 접촉률을 보였다. 표면처리군은 비처리군에 비해 임플랜트 주변에서 활발한 골개조가 관찰되었으며 모든 군에서 이물반응은 관찰되지 않았다. 본 연구를 통해 SLA 표면처리된 마이크로임플랜트는 평활면 마이크로임플랜트에 비하여 식립 초기에는 식립 부위에 따라 유의하게 높은 인접골 간 접촉률과 동요도의 안정성을 보임으로써 다양한 크기와 방향의 교정력의 적용이 가능할 것이라 생각한다.

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.

Calcium carbonate 및 자가골 이식술을 동반한 조직유도재생술후 생검을 통한 재생골의 조직학적 관찰 (Histologic observation of regenerated bone in human intraosseous lesion following guided tissue regeneration with calcium carbonate implant and autogenous bone graft)

  • 이용무;한수부;엄흥식;김동균
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.263-273
    • /
    • 1998
  • For histologic observation of the regenerated bone following guided tissue regeneration (GTR) using ePTFE membranes with calcium carbonate implant and autogenous bone graft, biopsies were collected from 2 patients during 5-year-postoperative surgical reentry. In both combined cases with guided tissue regeneration in conjunction with calcium carbonate implant and autogenous bone graft, significant bone fill and gain in probing attachment level was observed. In histologic examination, specimen in GTR case with calcium carbonate grafting was composed of a dense bone containing vascular channel with lamellar structure and viable bone cells in lacunae, however considerable calcium carbonate particles remained unresorbed and isolated from regenerated bone by the dense cellular and fibrous connective tissue. No formative cells could be seen in contact with remained calcium carbonate particles. In GTR case with autogenous bone grafting, specimen show was composed of a dense lamellar bone containing vascular channel, which showed normal alveolar bone architectures. The present observation indicate that guided tissue regeneration in conjunction with grafting, especially autogenous bone graft, has highly osteogenic potential, however resorbable calcium carbonate granules were not completely resorbed at 5 year postimplantation.

  • PDF

다양한 마이크로쓰레드(Micro thread)의 개수를 가지는 임플란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구 (Three-dimensional Stress Analysis of Implant Systems with Micro Threads in the Maxillary Bone)

  • 신하식;한종현;이수홍;전흥재
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.179-186
    • /
    • 2005
  • A comparative study of stress distributions in the maxillary bone with three different types of abutment was conducted. Finite element analysis was adopted to determine stress generated in the bone with the different implant systems with micro threads (Onebody type implant, Internal type implant, and External type implant). It was found that the types of abutments and the number of micro threads have significant influence on the stress distribution in the maxillary bone. They were due to the difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the maxillary bone was increased with increasing inclination angle of load. It was concluded that the maximum effective stress in the bone was the lowest by the internal implant among the maximum effective stresses by other two types of implants and by appropriate number of micro threads, and that the specific number of micro thread was existed to decrease the maximum effective stress in the maxillary bone due to different implant systems and loading conditions.

임플란트 보철의 교합 접촉 변화에 대한 임상적 평가 (Clinical Evaluation of Occlusal Contact Changes in Implant Prosthesis)

  • 윤철희;김대곤;이양진;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제23권1호
    • /
    • pp.21-30
    • /
    • 2007
  • Despite of the successful clinical performance of implants, it is still lacking of the knowledge of changes in implant occlusion. The purpose of this study was to evaluate the changes of infraocclusal contact after clinical occlusal function of implant. Twenty patients(38 implants) were recalled during 10 months after placement of implant prosthesis. Occlusion changes were investigated at placement, placement 1 months, 4 months and 10 months serially with silicone bite material and T-Scan II sensor. Bony changes were also evaluated with periapical radiographs. The changes of silicone thickness and T-Scan II sensored areas were statistically analyzed with repeated measured ANOVA and the Scheffe's post-hoc test at the 95% significance level. The following results have been made based on this study: 1. Alveolar bone loss was within 0.20mm and it was generally concluded within physiologic level. 2. There were no statistically significant differences in the thickness changes of silicone material at 1 month and 4 months of occlusal function. However, there was statistically significant difference at 10 months of occlusal function (p<0.05). 3. There was no statistically significant difference in changes of occlusal contact area in T-Scan II at 1 month and 4 months of occlusal function, but there was statistically significant difference at 10 months of occlusal function (p<0.05). Conclusively, as time goes by, implant occlusion to be formed infraocclusion was to be far close and increased occlusal contact. However, it was not observed destructive bone resorption in periapical radiographs and any other side effects.

역전사 중합효소 연쇄반응을 이용한 표면 적심성에 따른 골수유래 줄기세포의 생물학적 평가 (Biological Evaluation of Bone Marrow-Derived Stem Cells onto Different Wettability by RT-PCR)

  • 김은정;박종수;김문석;조선행;이종문;이해방;강길선
    • 폴리머
    • /
    • 제28권3호
    • /
    • pp.218-224
    • /
    • 2004
  • 고분자 생체재료에서 세포부착과 성장은 재료의 적심성, 화학구조, 표면전하 및 거칠기 등의 표면 성질에 의존한다. 본 연구에서는 저밀도 폴리에틸렌 필름 (LDPE)의 표면 적심성과 골수유래 줄기세포의 증식 및 성장성을 측정하기 위하여 플라즈마 처리를 실시하였으며 개질된 필름 표면의 특성을 조사하였다. 또한 LDPE 필름에서의 세포부착과 증식률은 세포수 관찰과 역전사 중합효소 연쇄반응으로 확인하였다. 표면성질의 하나인 물 접촉각 측정 결과 플라즈마 처리 시간이 길어짐에 따라 필름표면의 접촉각이 감소하였으며 암형성 유전자와 암억제 유전자의 발현률이 60∼70$^{\circ}$ 사이에서 높음을 확인할 수 있었다. 또한 세포수 관찰을 통해 접촉각이 60∼70$^{\circ}$인 표면에서 세포 증식률이 우수하여 표면성질이 세포의 성장과 분화에 중요함을 확인하였다.

Quantitative evaluation of alveolar cortical bone density in adults with different vertical facial types using cone-beam computed tomography

  • Ozdemir, Fulya;Tozlu, Murat;Cakan, Derya Germec
    • 대한치과교정학회지
    • /
    • 제44권1호
    • /
    • pp.36-43
    • /
    • 2014
  • Objective: The purpose of this study was to quantitatively evaluate the cortical bone densities of the maxillary and mandibular alveolar processes in adults with different vertical facial types using cone-beam computed tomography (CBCT) images. Methods: CBCT images (n = 142) of adult patients (20-45 years) were classified into hypodivergent, normodivergent, and hyperdivergent groups on the basis of linear and angular S-N/Go-Me measurements. The cortical bone densities (in Hounsfield units) at maxillary and mandibular interdental sites from the distal aspect of the canine to the mesial aspect of the second molar were measured on the images. Results: On the maxillary buccal side, female subjects in the hyperdivergent group showed significantly decreased bone density, while in the posterior region, male subjects in the hyperdivergent group displayed significantly decreased bone density when compared with corresponding subjects in the other groups (p<0.001). Furthermore, the subjects in the hyperdivergent group had significantly lower bone densities on the mandibular buccal side than hypodivergent subjects. The maxillary palatal bone density did not differ significantly among groups, but female subjects showed significantly denser palatal cortical bone. No significant difference in bone density was found between the palatal and buccal sides in the maxillary premolar region. Overall, the palatal cortical bone was denser anteriorly and buccal cortical bone was denser posteriorly. Conclusion: Adults with the hyperdivergent facial type tend to have less-dense buccal cortical bone in the maxillary and mandibular alveolar processes. Clinicians should be aware of the variability of cortical bone densities at mini-implant placement sites.