• Title/Summary/Keyword: Bone Structure

Search Result 539, Processing Time 0.049 seconds

An Implementation of Classification Method of Osteoporosis using CT images (CT 영상을 이용한 골다공증 분류 방법의 구현)

  • Jung, Sung-Tae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, we propose a method of measuring bone mineral density in a peripheral-type clinical X-ray CT using a phantom, and we propose a method of classifying osteoporosis using bone mineral density and bone structure parameters together. It segments the trabecular bone region and cortical bone region for the six sections of the phantom and calculates the average HU value of the segmented regions. By using these values, it derives an expression converting HU value to bone mineral density. It segments trabecular bone of 1 cm region in the end part of distal radius and extracts the bone mineral density and structural parameters for the trabecular bone region. We extracted bone mineral density and structural parameters for the 18 subjects each of normal and osteoporotic group. We carried out classification experiments using three classification methods; SAD, SVM, ANN. The sensitivity, specificity, accuracy, positive predictive value, negative predictive value, likelihood ratio of the classification was improved in the order of ANN, SVM and SAD. Also, The sensitivity, specificity, accuracy, positive predictive value, negative predictive value, likelihood ratio of the classification was improved when we use the bone mineral density and structural parameters together.

3D porous ceramic scaffolds prepared by the combination of bone cement reaction and rapid prototyping system

  • Yun, Hui-Suk;Park, Ui-Gyun;Im, Ji-Won
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.56.2-56.2
    • /
    • 2012
  • Clinically-favored materials for bone regeneration are mainly based on bioceramics due to their chemical similarity to the mineral phase of bone. A successful scaffold in bone regeneration should have a 3D interconnected pore structure with the proper biodegradability, biocompatibility, bioactivity, and mechanical property. The pore architecture and mechanical properties mainly dependent on the fabrication process. Bioceramics scaffolds are fabricated by polymer sponge method, freeze drying, and melt molding process in general. However, these typical processes have some shortcomings in both the structure and interconnectivity of pores and in controlling the mechanical stability. To overcome this limitation, the rapid prototyping (RP) technique have newly proposed. Researchers have suggested RP system in fabricating bioceramics scaffolds for bone tissue regeneration using selective laser sintering, powder printing with an organic binder to form green bodies prior to sintering. Meanwhile, sintering process in high temperature leads to bad cost performance, unexpected crystallization, unstable mechanical property, and low bio-functional performance. The development of RP process without high thermal treatment is especially important to enhance biofunctional performance of scaffold. The purpose of this study is development of new process to fabricate ceramic scaffold at room temperature. The structural properties of the scaffolds were analyzed by XRD, FE-SEM and TEM studies. The biological performance of the scaffolds was also evaluated by monitoring the cellular activity.

  • PDF

Biomechanical stability of internal bone-level implant: Dependency on hex or non-hex structure

  • Lee, Hyeonjong;Park, Si-Myung;Noh, Kwantae;Ahn, Su-Jin;Shin, Sangkyun;Noh, Gunwoo
    • Structural Engineering and Mechanics
    • /
    • v.74 no.4
    • /
    • pp.567-576
    • /
    • 2020
  • Considerable controversy surrounds the choice of the best abutment type for implant prosthetics. The two most common structures are hex and non-hex abutments. The non-hex abutment typically furnishes a larger contact area between itself and the implant than that provided by a hex structure. However, when a hex abutment is loaded, the position of its contact area may be deeper than that of a non-hex abutment. Hence, the purpose of this study is to determine the different biomechanical behaviors of an internal bone-level implant based on the abutment type-hex or non-hex-and clinical crown length under static and cyclic loadings using finite element analysis (FEA). The hex structure was found to increase the implant and abutment stability more than the nonhex structure among several criteria. The use of the hex structure resulted in a smaller volume of bone tissues being at risk of hypertrophy and fatigue failure. It also reduced micromovement (separation) between the implant components, which is significantly related to the pumping effect and possible inflammation. Both static and fatigue analyses, used to examine short- and long-term stability, demonstrated the advantages of the hex abutment over the non-hex type for the stability of the implant components. Moreover, although its impact was not as significant as that of the abutment type, a large crown-implant ratio (CIR) increased bone strain and stress in the implant components, particularly under oblique loading.

A computed tomography-based analysis of the structure of the mandible according to age and sex

  • Jung, Soyeon;Yun, Hyunjong;Chung, Chul Hoon;Kim, Kuylhee;Chang, Yongjoon
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.3
    • /
    • pp.103-110
    • /
    • 2022
  • Background: The primary objectives of mandibular surgery are to achieve optimal occlusion, low sensory disturbance, and adequate fixation with early movement. In-depth knowledge of the mandibular structure is required to achieve these goals. This study used computed tomography (CT) to evaluate the mandibular cortical thickness and cancellous space according to age and sex. Methods: We enrolled 230 consecutive patients, aged 20 to 50 years, who underwent CT scanning. The cortex and cancellous space centered around the inferior alveolar nerve (IAN) canal were measured at two specific locations: the lingula and second molar region. Statistical analysis of differences according to increasing age and sex was performed. Results: The t-test revealed that the cancellous space and cortical thickness differed significantly with respect to the threshold of 35 years of age. Both cortical thickness and cancellous space in the molar region were negatively correlated with age. Meanwhile, both cortical thickness and cancellous space in the lingula region showed a positive correlation with age. With respect to sex, significant differences in the cancellous space at the molar region and the cortical thickness at the lingula were observed. However, no further statistically significant differences were observed in other variables with respect to sex. The sum of each measurement on the mandibular body reflected the safe distance from the surface of the outer cortex to the IAN canal. The safe distances also showed statistically significant differences between those above and below 35 years of age. Conclusion: Knowledge of the anatomical structure of the mandible and of changes in bone structure is crucial to ensure optimal surgical outcomes and avoid damage to the IAN. CT examination is useful to identify changes in the bone structure, and these should be taken into account in the planning of surgery for older patients.

The relationship between 3D bone architectural parameters and elastic moduli of three orthogonal directions predicted from finite elements analysis (돼지 하악 과두의 해면골에서 유한요소분석법으로 예측한 방향에 따른 탄성율과 3차원 골 미세지표 간의 상관관계)

  • Park, Kwan-Soo;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • Purpose: To investigate the relationship between 3D bone architectural parameters and direction-related elastic moduli of cancellous bone of mandibular condyle. Materials and Methods: Two micro-pigs (Micro-$pig^R$, PWG Genetics Korea) were used. Each pig was about 12 months old and weighing around 44 kg. 31 cylindrical bone specimen were obtained from cancellous bone of condyles for 3D analysis and measured by micro-computed tomography. Six parameters were trabecular thickness (Tb. Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI), degree of anisotropy (DA) and 3-dimensional fractal dimension (3DFD). Elastic moduli of three orthogonal directions (superior-inferior (SI), medial-lateral (ML), andterior-posterior (AP) direction) were calculated through finite element analysis. Results: Elastic modulus of superior-inferior direction was higher than those of other directions. Elastic moduli of 3 orthogonal directions showed different correlation with 3D architectural parameters. Elastic moduli of SI and ML directions showed significant strong to moderate correlation with BV/TV, SMI and 3DFD. Conclusion: Elastic modulus of cancellous bone of pig mandibular condyle was highest in the SI direction and it was supposed that the change into plate-like structure of trabeculae was mainly affected by increase of trabeculae of SI and ML directions.

  • PDF

Review on the Correlation between Bone Mass, Skinfold Thickness and the Volume of Urine collagen Peptide in Postmenopausal Women (폐경 후 여성의 골량과 피부두겹두께 및 뇨 콜라겐펩타이드 양의 관련성에 대한 고찰)

  • Park, Mi-Jung
    • Journal of Korean Biological Nursing Science
    • /
    • v.3 no.2
    • /
    • pp.91-103
    • /
    • 2001
  • The bone is composed of the bone matrix of collagen and hydroxyapatite, the mixture of calcium and phosphours. The bone tissue is considered to the special connective tissue that possesses extracellular matrix made by collagen fiber deposited with mineral complex. In order to maintain bone mass measured by the sum of bone matrix and hydroxyapatite, bone resorption by osteoclast during lifetime and bone remodeling to form bone by osteoblast in its resorption region repeat continuously. The osteoblast has a mesodermic fetal origin like fibroblast for the formation of form tissues. Two cells express identical genes and synthesize the identical collagen type I as the major component of the formation of bone matrix and skin. Therefore, it is considered that the decrease of skinfold thickness and the decrease of bone mass related to the age, the change of two tissues composed of collagen type I is caused by the same genetic mechanism. The decrease of bone mass is caused by the change of the amount and structure of bone matrix by several factors and the amount of minerals deposited on bone matrix. Especially, in case of female, the deficiency of estrogen by menopause makes these changes rapidly increased. The decrease of bone mass and skinfold thickness is due to the decrease of the amount of collagen and its structural change the common component of bone tissue and skin tissue. Therefore, the relationship of the amount of cross-linked peptide N-telopeptide, collagen metabolite which excretes as urine. Based upon the proved results about the significant relationship of bone mass, the amount of bone collagen, the amount of skin collagen and skinfold thickness, the bone mass may be expected through a facile determination of skinfold thickness.

  • PDF

Anatomical Studies on the Skeleton of Pelvic Limb of Korean Native Goat (한국재래산양의 후지골격에 관한 해부학적 연구)

  • Kim, Jin-sang;Lee, Heung-shik S.;Lee, In-se;Yoon, Yeo-sung
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.1
    • /
    • pp.1-16
    • /
    • 1988
  • The anatomical structure of pelvic limb, of thirty-one adult Korean native goats (Body weight: 14~17kg) was observed after skeletal preparation, and the osteometry was performed in each bone. The results were as follows: 1. The pelvic limb of the Korean native goat was composed of the hip bone, femur, patella, tibia, fibula, tarsal bones, metatarsal bone, phalanges and sesamoid bones. 2. The hip bone consisted of the ilium, ischium and pubis which fused each other, The gluteal surface of the ilium was directed dorsolaterally. The tuber sacrale and tuber coxae were formed at the dorsal apex and ventrolateral part of the iliac wing, respectively. The lesser ischiatic notch was deeper than the greater one. The ischiatic tubercles were triangular form and consisted of the dorsal, lateral and caudal ischiatic tubercles. The left and right hip bone indexes were 67.08, 66.20, the acetabular indexes were 93.78 and 92.10 and the obturator foramen. indexes were 53.84 and 54.77, respectively. 3. In femur, both of the greater and lesser trochanter were well developed but the third trochanter was not observed. The left and right femur indexes were 26.55 and 26.14, head indexes were 81.66 and 81.49 and the trochlear-epicondyle indexes were 42.47 and 41.63, respectively. 4. The patella was observed as an isosceles triangle with base lying proximal and the cranial surface was more convex. 5. The tibial shaft was sigmoid form and the popliteal notch was deep. There was a large nutrient foramen at the cranial aspect of the cranial intercondylar area. The tibial indexes were 22.09 in left and 21.10 in right. 6. The proximal extremity of the fibula was fused with the lateral condyle of the tibia but the distal one was observed independently as the malleolar bone. 7. The tarsal bones were five in number; the talus, calcaneus, centroquartal tarsal bone, first tarsal bone, and second-third tarsal bone. 8. The metatarsal bone was composed of a large metatarsal bone. resulted from the fusion of the third and fourth metatarsal bones, The structure of metatarsal bone was similar to the metacarpal bone but longer about 7mm. 9. The phalanges and sesamoid bones were similar to these of the thoratic limb. 10. The ratios of the lengths among the hip bone, femur, tibia and metafarsal bone were 1.71 : 1.54 : 1.73 : 1.00 in left and 1.68 : 1.53 : 1.72 : 1.00 in right, respectively.

  • PDF

A Parameter Study on the Frequency Characteristics Control of Implantable Bone Conduction Transducer Using FEA (FEA를 이용한 이식형 골전도 진동체의 주파수 특성 제어에 관한 파라미터 연구)

  • Shin, Dong Ho;Kim, Myoung Nam
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.8
    • /
    • pp.1040-1048
    • /
    • 2020
  • In this study, in order to improve the implantable bone conduction transducer of the prototype proposed by Shin et al., the effect of the element parameters of the transducer on the frequency characteristics was analyzed using electromagnetic and mechanical vibration analysis. Electromagnetic analysis was performed on the size of the permanent magnet and the distance between the metal plate and the coil to derive an optimal structure that generates the maximum Lorentz force. In addition, mechanical vibration analysis was performed on the cantilever structure of the vibrational membrane in order to minimize the distortion of the transducer and to have a frequency characteristic suitable for conductive hearing loss compensation. The frequency characteristics of the transducer of the optimal structure derived through finite element method were compared with the simulation results of the previous transducer. As a result, the output magnitude (displacement) of the transducer designed with the optimal structure generated an average 8.8 times higher than the previous transducer, and the resonance frequency was generated at 0.9 kHz.

A Study on Noise and Vibration Characteristics of Pipe Structures (파이프 구조물의 소음 및 진동특성 연구)

  • 류봉조;임경빈;이규섭;송영봉;공용식;오부진
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.334-337
    • /
    • 2002
  • The paper presents noise and vibration characteristics of three kinds of pipe materials (PVC pipe, cast-iron pipe and newly developed pp pipe). In order to measure structure bone noise, impact force using small balls was applied to earth pipe. It was confirmed that structure bone noise can be reduced by more large damping materials. Also, transmission loss of pipes depending on the frequency ranges was investigated by using sound source through speakers.

  • PDF