• 제목/요약/키워드: Bone Fluid

검색결과 197건 처리시간 0.025초

Strain Rate Dependent Poroelastic Behavior of Bovine Vertebral Trabecular Bone

  • Hong, Jung-Hwa;Mum, Mu-Seong;Lim, Tae-Hong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1032-1040
    • /
    • 2001
  • It is widely accepted that the pressure variation of interstitial fluid is one of the most important factors in bone physiology. In order to understand the role of interstitial fluid on porous bony structure, a consideration for the biomechanical interactions between fluid and solid constituents within bone is required. In this study, a poroelastic theory was applied to investigate the elastic behavior of calf vertebral trabecular bone composed of the porous solid trabeculae and the viscous bone marrow. The poroelastic behavior of trabecular bone in a uniaxial stress condition was simulated using a commercial finite difference analysis software (FLAC, Itasca Consulting Group, USA), and tested for 5 different strain rates, i.e., 0.001, 0.01, 0.1, and 10 per second. The material properties of the calf vertebral trabecular bone were utilized from the previous experimental study. Two asymptotic poroelastic responses, the drained and undrained deformations, were predicted. From the predicted results for the simulated five strain rates, it was found that the pore pressure generation has a linearly increasing behavior when the strain rate is the highest at 10 per second, otherwise it showed a nonlinear behavior. The pore pressure generation with respect to the strain was found to be increased as the strain rate increased. The elastic moduli predicted at each strain were 208.3, 212.2, 337.6, 593.1, and 602.2 MPa, respectively. Based on the results of the present study, it was suggested that the calf vertebral trabecular bone could be modeled as a poroelastic material and its strain rate dependent material behavior could be predicted.

  • PDF

New Fluid Flow System for Simulation of Mechanical Loading to Bone Cells During Human Gait Cycle

  • Ahn, Jae-Mok
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권3호
    • /
    • pp.377-386
    • /
    • 2007
  • Mechanical loading to bone cells using simple sine wave or constant wave fluid flow has been widely used for in vitro experiments. Human gait is characterized by a complex loading to bones of lower extremities which results from a series of events consisting of heel strike, foot flat and push-off during the stance phase of the gait cycle. Telemetric force analyses have shown that human femora are subject to multiphasic loading. Therefore, it would be ideal if the physiologic loading conditions during human walking can be used for in vitro mechanotransduction studies. Here, for a mechanotransduction study, we develop it fluid flow system (FFS) in order to simulate human physiologic mechanicalloading on bone cells. The development methods of the FFS including the COR (Center for Orthopedic Research), monitor program are presented. The FFS could generate various multiphasic loading conditions of human gaits with output flow. Wall shear distribution was very uniform, with 81 % of the effective loading area of the culture on a glass slide. Our results demonstrated that the FFS, provide a new translational approach for unveiling molecular mechanotransduction pathways in bone cells.

임상가를 위한 특집 2 - 교정력에 의한 치아이동과 Biomechanical adaptation (Biomechanical adaptation of orthodontic tooth movement)

  • 이승일
    • 대한치과의사협회지
    • /
    • 제51권3호
    • /
    • pp.138-147
    • /
    • 2013
  • Orthodontic tooth movement is a unique process which tooth, solid material is moving into hard tissue, bone. Orthodontic force in general provides the strain to the PDL and alveolar bone, which in turn generates the interstitial fluid flow(in detail, fluid flow in PDL and canaliculi). As a results of matrix strain, periodontal ligament cells and bone cells are deformed, releasing variety of cytokines, chemokines, and growth factors. These molecules lead to the orthodontic tooth movement(OTM). In these inflammation and tissue remodeling sites, all of the cells could closely communicate with one another, flowing the information for tissue remodeling. To accelerate the rate of OTM in future, local injection of single growth factor(GF) or a combination of multiple GFs in the periodontal tissues might intervene to stimulate the rate of OTM. Corticotomy is effective and safe to accelerate OTM.

전기방사로 제조된 다층 Poly Methyl Methacrylate (PMMA)/Poly Vinyl Alcohol (PVA) Bone Plate의 생체적합성 평가 (Biocompatibility of Multilayer Poly Methyl Methacrylate (PMMA)/Poly Vinyl Alcohol (PVA) Bone Plate by Electrospinning Method)

  • 곽경아;김영희;;이병택;송호연
    • 한국재료학회지
    • /
    • 제20권6호
    • /
    • pp.312-318
    • /
    • 2010
  • Multilayer Poly methyl methacrylate (PMMA)/ Poly vinyl alcohol (PVA) bone plates were fabricated using electrospinning and in vitro investigations were carried out for pre-clinical biocompatibility studies. The initial cellular cytotoxicity of the methacrylate (PMMA)/ Poly vinyl alcohol (PVA) bone plates was measured by MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay using fibroblast-like L-929 cells. Cellular adhesion and differentiation studies were carried out using osteoblast-like MG-63 cells. As simulated body fluid (SBF) contains the same ionic concentration of body fluid and any bioactive material tends to deposit bone-like apatite on the samples surfaces into the SBF, in vitro bioactivity of the multilayer bone plates were investigated using SBF. We also studied the internal organization and tensile strength of the multilayer PMMA/PVA bone plates using micro-computed topography (${\mu}$-CT) and universal testing instrument (UTI, Korea) respectively. The cellular cytotoxicity study with MTT confirmed that the cellular viability was 78 to 90% which indicates good cyto-compatibility. Scanning electron microscopic findings revealed a good attachment and adhesion phenomenon of MG-63 cells onto the surfaces of the samples. Cellular differentiation studies also showed that osteogenic differentiation was switched on in a timely manner and affirmed along with that of the control group. Bone-like apatite formation on the surfaces was confirmed within 14 days of SBF incubation. Initial organizations of the multilayer PMMA/PVA bone plates were characterized as dense and uniform. The tensile strength of the post-pressing electronspun mat was higher than that of the pre-electronspun mat. These results suggest that a multilayer PMMA/PVA bone plate system is biocompatible, bioactive and a very good alternative bone plate system.

The piezoelectricity of trabecular bone in cancellous bone wave propagation

  • Yoon, Young June;Chung, Jae Pil
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.104-107
    • /
    • 2021
  • The orientation of trabeculae and porosity determine the wave propagation in cancellous bone. Wave propagation, as well as charge density and piezoelectricity, stimulate bone remodeling. Also, Charged ions in the fluid affect wave propagation in cancellous bone. But the trabecular struts' piezoelectricity does not change the waveform of cancellous bone. However, the underlying mechanism is unknown yet why trabecula struts' piezoelectricity does not change wave propagation through cancellous bone. Thus, we derived the governing equation indicating that trabecular struts' piezoelectric properties show that those do not affect wave propagation in cancellous bone.

Electrospinning으로 제조된 PMMA/PVA Multilayer bone plate의 생체적합성에 관한 연구

  • 곽경아;;이병택;송호연
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.43.1-43.1
    • /
    • 2009
  • Bone plate는 골절된 뼈의 골 유합을 지지하기 위해서 정형외과, 신경외과, 성형외과 및 치과 등에서 널리 사용되고 있다. 하지만 기존의 bone plate는 대부분 금속으로 제작되어 있어 장기간 이식에 따른 부식 및 천연골 강도저하 등으로 인해 1~2년 후 재수술을 해야 하는 문제점을 갖고 있다. 본 연구에서는이런 금속 bone plate의 단점을 개선하고자 생체적합성이 우수한 생분해성 고분자 bone plate를 제작하였다. 사용된 고분자는 생체적합성과 생분해성이우수한 PVA(polyvinly alcohol)와 강도를 유지하기 위한 PMMA(poly methyl methacrylate)를 사용였다. Electrospinning 법으로 PVA와 PMMA fibrous mat를 제작하여 각 mat를 적층시킨 후 열압착을 하여 강도를 증가시킨 PMMA/PVA Mutlilayer bone plate을 제작하였다. 제작된 PMMA/PVA Mutlilayer bone plate의 생체적합성 평가를 위해 MTT assay, 생분해 특성을 관찰하기 위해 Micro-CT와 SBF(simulated body fluid) 내에서의 용해도를 관찰하였다. 또한조골세포의 부착과 분화에 미치는 영향을 SEM(scanning electron microscope)을통해 관찰하였고, 조골세포의 유전자 발현에 미치는 영향을 RT-PCR을통해 확인하였다.

  • PDF

$^{99m}Tc-MDP$를 이용한 Bone scan 시간(時間)에 관(關)한 고찰(考察) (A Study of Bone Scan Time by Use of $^{99m}Tc-MDP$)

  • 박성옥;이현배
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권1호
    • /
    • pp.77-86
    • /
    • 1994
  • The bone scan reflects the metabolic reaction of bone to a disease process, whether neoplastic, traumatic or inflammatory. In normal bone tissue, the labeled diphosphate complexes accumulate in the perivascular fluid next to the marrow cavity at the interface between uncalcified and calcified bone matrix. HMDP has the most rapid plasma clearance among the commonly used diphosphonate followed by MDP and then HEDP. I have studied about bone scan time by use of $^{99m}Tc-MDP$, and got 336 images from 112 patients. The result obtained as follow; 1. Accumulation rate of $^{99m}Tc-MDP$ is higher than other age groups in below 30-year old group. 2. Accumulation rate, in 10year old group, is 75.85% on 120min. but other groups are most high on 180 min. 3. The density differants between bone and soft tissue increased with time. 4. Image contrast is good in younger group than old.

  • PDF