• Title/Summary/Keyword: Bone Density Measuring Instrument

Search Result 2, Processing Time 0.021 seconds

Comparison Measurement Error of T-score Between Lumbar and Femoral Neck According to Kind of DXA (DXA측정기 종류에 따른 요추부와 대퇴경부 골밀도 값의 측정오차 비교)

  • Han, Beom-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan;Lee, Hye-Nam;Jeong, Cheon-Soo;Lee, Sang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.3
    • /
    • pp.250-257
    • /
    • 2010
  • In this study, three different devices, Norland, Osteocore and Lunar were used to compare and analyze the measurement error by each bone density measurement device by classifying the physical characteristics into age, height and weight, the subject of total 300 sampling 100 persons for each device. Categorizing Lumbar region and Femoral neck as normal (T-score$\geqq$-1.0), osteopenia (-1.0>T-score>-2.5) and osteoporosis (T-score$\leqq$-2.5), the findings were observed as follows. Norland device showed the least measurement error in age and height, while Lunar showed the least in weight among the devices. And, the result of comparing the bone density measurement error based on the lumbar region showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteopenia and the result of comparing based on the femoral neck showed that all of Lunar, Norland and Osteocore have the least variation of measurement error in osteoporosis. For each variable, the measurement error was observed to be vary upon the device. To solve this, standardized common Phantom should be used to compare and converge the measured value of each company and cross-calibration would be necessary when replacing the software.

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF