• Title/Summary/Keyword: Bone Characteristics

Search Result 944, Processing Time 0.031 seconds

Pediatric dual-energy X-ray absorptiometry: interpretation and clinical and research application

  • Lim, Jung Sub
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.3
    • /
    • pp.286-293
    • /
    • 2010
  • Peak bone mass is established predominately during childhood and adolescence. It is an important determinant of future resistance to osteoporosis and fractures to gain bone mass during growth. The issue of low bone density in children and adolescents has recently attracted much attention and the use of pediatric dual-energy X-ray absorptiometry (DXA) is increasing. The process of interpretation of pediatric DXA results is different from that of adults because normal bone mineral density (BMD) of children varies by age, body size, pubertal stage, skeletal maturation, sex, and ethnicity. Thus, an appropriate normal BMD Z-score reference value with Z-score should be used to detect and manage low BMD. Z-scores below -2.0 are generally considered a low BMD to pediatrician even though diagnoses of osteoporosis in children and adolescents are usually only made in the presence of at least one fragility fracture. This article will review the basic knowledge and practical guidelines on pediatric DXA based on the International Society for Clinical Densitometry (ISCD) Pediatric Official Positions. Also discussed are the characteristics of normal Korean children and adolescents with respect to BMD development. The objective of this review is to help pediatricians to understand when DXA will be useful and how to interpret pediatric DXA reports in the clinical practice for management of children with the potential to develop osteoporosis in adulthood.

AN EXPERIMENTAL STUDY ON THE REACTION OF PULPAL CELLS TO THE IMPLANTED DEMINERALIZED BONE MATRIX (탈회골기질 이식에 대한 치수세포의 반응에 관한 실험적 연구)

  • Kim, Sun-Hun;Kim, Min-Seok;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.744-757
    • /
    • 1995
  • Implantation of demineralized bone matrices was done into the amputated pulp in vivo and sequential reaction of the pulpal ectomesenchymal cells was observed. The bone matrices, obtained from cat long bone were crushed into below $700{\mu}m$, demineralized with 0.5N HCl and allografted into pulp of molar teeth. At seven days after implantation many undifferentiated mesenchymal cells aggregated near the matrices in the pulpal tissue. At fourteen days after implantation, the cells differentiated into preosteoblast-like cells which have secretory cell characteristics. At one or two months after implantation osteoid tissue was formed. The cells, which are located at the surface of the tissue, contained abundant dilated rough endoplasmic reticulum, Golgi apparatus and secretory granules in the cytoplasm. The matrix of the tissue has less collagen fibers than those in normal dentin. These results suggest that the interaction of pulpal mesenchymal cells with demineralized bone matrix can be a model which induces mineralization.

  • PDF

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Effect of Whole Body Vibration on Osteoporotic Trabecular Bone of Rats - Compared with the Effect of Actonel (전신진동이 골다공증이 유발된 쥐 해면골에 미치는 영향 - 골다공증 치료제 효과와 비교)

  • Ko, Chang-Yong;Lee, Tae-Woo;Woo, Dae-Gon;Kim, Hyo-Seon;Kim, Han-Sung;Lee, Beob-Yi;Lim, Do-Hyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.5
    • /
    • pp.148-154
    • /
    • 2008
  • Pharmacotherapy was mainly used to treat osteoporosis. However, some researches showed that pharmacotherapy could induce unexpected adverse effects. Some studies showed that whole body vibration affected beneficially osteoporosis. This paper studied the effect of whole body vibration fur osteoporosis compared with the effect of pharmacotherapy. 10 female rats were used and allocated into 4 group, CON, SHAM, DRUG, and WBV. Rats except SHAM group were ovariectomised to induce osteoporosis. Rats in WBV group were stimulated in whole body vibration at magnitude of $1mm_{peak-peak}$ and frequency 45Hz, for 8 weeks (30 min/day, 5 days/week). Rat in DRGU group was orally administered the Actonel (0.58mg/Kg), for 8 weeks (5days/week). The $4^{th}$ lumbar in rats were scanned at a resolution of $35{\mu}m$ at baseline, before stimulation, and 8 weeks after stimulation by In-vivo micro computed tomography. For detecting and tracking changes of biomechanical characteristics (morphological and mechanical characteristics) in lumbar trabecuar bone of rats, structural parameters were measured and calculated from acquiring images and finite element analysis was performed. In the results, loss of quantity and change of structure of trabecular bone in WBV group were smaller than those in both CON and SHAM groups. In addition, mechanical strength in WBV group was stronger than that in both CON and SHAM groups. In contrast, biomechanical characteristics in WBV group were similar with those in DRUG group. These results showed that reasonable whole body vibration was likely to treat osteoporosis and be substituted partly for drug treatment.

Comparison of Physical Characteristics and Lower Extremity Biomechanics of Elderly and Young Adult Runners (노인 러너의 신체특성과 하지관절의 생체역학적 비교)

  • Kim, Jong-Bin;Ha, Sunghe;Park, Sangheon;Yoon, Sukhoon;Ryu, Ji-seon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.3
    • /
    • pp.145-155
    • /
    • 2019
  • Objective: The purpose of this study was to compare the physical characteristics (bone mineral density, joint muscle strength) and running biomechanics between older adults and young adult runners to understand the changes of running strategy by aging. Method: Bone mineral density (Dual Energy X-ray Absorptiometry, USA) of lower lower extremity and muscle strength (Cybex Humac Norm [DEXA], CSMI, USA) were measured to identify the physical characteristics of 10 elderly (age: $67.70{\pm}3.30yrs$, height: $1.68{\pm}0.04m$, mass: $67.70{\pm}3.80kg$) and 10 young adults (age: $21.20{\pm}0.42yrs$, height: $1.73{\pm}0.06m$, mass: $72.11{\pm}4.15kg$). Running data was collected by using an instrumented treadmill (Bertec, USA) and 7 infrared cameras (Oqus 300, Qualisys, Sweden). Two-way repeated ANOVA analysis was used to analyze results at a significant level of .05 with Bonferroni post hoc analysis. Results: Compared to the young adult group, the elderly group showed statistically significant difference in physical characteristics and in running characteristics. Elderly runners showed lower BMD and muscle strength compared with young runners (p<.05). In the running parameters, elderly runners tend to show shorter contact time and stride length compared with young runners (p<.05). In the joint angles, elderly runners showed smaller range of ankle motion compared with young runners (p<.05). Finally, elderly runners showed lower level of joint moment, joint power, and GRF compared with young runners in each running speed (p<.05). Conclusion: The running behavior of the elderly performed periodic running was similar to many variables of young adults. However, there were noticeable differences found in the ankle joints and most kinetic variables compared with young adult runners. This discrepancy may propose that elderly runners should consider appropriate running distance and intensity in the program.

Characteristics of Stable Pelvic Bone Fractures with Intra-abdominal Solid Organ Injury (복부 고형장기 손상을 동반한 안정 골반골 골절의 특성)

  • Park, Sang-June;Kim, Sun-Hyu;Lee, Jong-Hwa;Ahn, Ryeok;Hong, Eun-Seog
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Purpose: This study analyzed the characteristics of stable pelvic bone fractures with intra-abdominal solid organ injury. Methods: Medical records were retrospectively reviewed from January 2000 to December 2009 of patients with stable pelvic bone fractures. A stable pelvic bone fracture according to Young's classification is defined as a lateral compression type I and antero-posterior compression type I. Subjects were divided into two groups, one with (injured group) and one without (non-injured group) intra-abdominal solid organ injury, to evaluate the dependences of the characteristics on the presence of an intra-abdominal solid organ injury. Data including demographics, mechanism of injury, initial hemodynamic status, laboratory results, Revised Trauma Score (RTS), Abbreviated Injury Scale (AIS), Injury Severity Score (ISS), amount of transfusion, admission to intensive care unit (ICU), and mortality were analyzed. Results: The subjects were 128 patients with a mean age of 42 years old, of whom were 67 male patients (52.3%). The injured group had 21 patients(16.4%), and the most frequent injured solid organ was the liver. Traffic accident was the most common mechanism of injury and lateral compression was the most common type of fracture in all groups. Initial systolic blood pressure was lower in the injured group, and the ISS was greater in the injured group. Arterial pH was lower in the injured group, and shock within 24 hours after arrival at the emergency department was more frequent in the injured group. Transfused packed red blood cells within 24 hours were 8 patients(38.1%) in the injured group and 11 patients(10.3%) in the non-injured group. Conservative treatment was the most common therapeutic modality in all groups. Stay in the ICU was longer in the injured group, and three mortalities occurred. Conclusion: There is a need to decide on a diagnostic and therapeutic plan regarding the possibility of intra-abdominal solid organ injury for hemodynamically unstable patients with stable pelvic bone fractures and for patients with stable pelvic bone fractures along with multiple associated injuries.

Effects of Levels of L-Leucine Supplementation with Sub-optimal Protein in the Diet of Grower-finisher Broiler Chickens on Carcass Composition and Sensory Characteristics

  • Erwan, E.;Alimon, A.R.;Sazili, A.Q.;Yaakub, H.;Karim, R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.5
    • /
    • pp.650-654
    • /
    • 2011
  • An experiment involving 180 straight run one-day-Cobb broilers was conducted to evaluate the effect of supplementation of L-leucine with different levels of crude protein (CP) on carcass composition and sensory characteristics of broiler grower-finisher chickens. Six experimental diets comprising two levels of crude protein (CP) i.e., 20 and 20% with three levels of L-leucine i.e. 0, 0.5 and 0.67%, were offered to birds from 21-42 d of age. The birds were randomly divided into 36 experimental pens, 5 chickens in each pen, and there were 6 replicates under each diet. L-leucine supplementation did not affect the bone and lean, whereas fat was decreased (p<0.05) when L-leucine was added at 0.5%. Similarly, there were no significant differences (p>0.05) in the lean, fat and bone among chickens fed two levels of CP. No significant differences between dietary treatments were observed on any sensory characteristics affected by dietary L-leucine and CP. From this study, it is obvious that supplementation of up to 0.5% L-leucine reduced fat. However, other characteristics were not affected by supplementation of L-leucine. Similarly, reduction of body composition and sensory characteristics were not apparent on a diet low in CP.

Comparison of Gap Pressure in Opening Wedge High Tibial Osteotomy versus Compressive Strength of Allogenous Wedge Bone Blocks (경골 근위부 개방 절골술 시 개방부 압력과 동종 쐐기 골편의 최대압축하중 비교)

  • Yoon, Kyoung Ho;Kim, Jung Suk;Kwon, Yoo Beom;Kim, Eung Ju;Lee, Myeong-Kyu;Kim, Sang-Gyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.127-134
    • /
    • 2020
  • Purpose: The aims of this study were (1) to investigate the relationship between the characteristics of allogenic bone block and the compressive strength of an allogenic bone block measured by biomechanical experiments, and (2) to compare the maximum pressure load of allogenic bone block with the gap pressure measured at the high tibial opening osteotomy. Materials and Methods: Ten patients who provided informed consent for gap pressure measurements during opening wedge high tibial osteotomy (OWHTO) were included. The gap pressures were measured at 1 mm intervals while opening the osteotomy site from 8 mm to 14 mm. Seventeen U-shaped allogenous wedge bone blocks were made from the femur, tibia, and humerus. The height, width, cross-sectional area, and cortex thickness of the bone blocks were measured, along with the maximum compressive load just before breakage. The relationship between these characteristics and the maximum pressure load of the bone blocks was evaluated. The gap pressures measured in OWHTO were compared with the maximum pressure loads of the allogenous wedge bone blocks to evaluate the possibility of inserting allogenous wedge bone blocks into the osteotomy site without a distractor in OWHTO. Results: The OWHTO gap pressure increased with increasing osteotomy site opening. The mean gap pressure, which occurred at a 14-mm opening, was 282±93 N; the maximum pressure was 427 N. The maximum pressure load of the allografts was 13,379±6,469 N (minimum, 5,868; maximum, 29,130 N) and was correlated significantly with the cortical bone thickness (correlation coefficient=0.693, p=0.002) and cross-sectional area (correlation coefficient=0.826, p<0.001). Depending on the sterilization method, the maximum pressure loads for the bone blocks were 13,406±5,928 N for freeze-dried and 13,348±7,449 N for fresh frozen. The maximum compressive load of the allogenous wedge bone blocks was 13.7-times greater than that in OWHTO opened to 14 mm (5,868 N vs. 427 N). Conclusion: The compressive strength of allogenous wedge bone blocks was sufficiently greater than the gap pressure in OWHTO. Therefore, allogenous wedge bone blocks can be inserted safely into the osteotomy site without a distractor.

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.