• Title/Summary/Keyword: Bond characteristic

Search Result 175, Processing Time 0.023 seconds

Analysis and Environment on Bond Characteristic of High-Strength Steel RC Members (고장력 철근을 사용한 RC부재의 부착특성에 관한 해석 및 실험)

  • 곽성태;윤영수;송영철;우상균
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.443-448
    • /
    • 2001
  • This paper presents a bond characteristics of high strength steel reinforced concrete members. High strength steel is what yield strength is higher than that of normal strength steel. So, the amount of flexural steel needed in R.C. members can be decreased. In result, it is expected that the workability and structure quality can improve and man power can minimize. For this purpose, specimens were made and tested with experimental parameters, such as concrete strength, steel diameter and yield strength. The result showed that under same tensile force of steel, in case of substituting normal strength steel with high strength steel, maximum bond stress increased and development length didn't almost change. In addition, the governing equation of bond and bond stress verse slip relationship were derived and compared with test values such as maximum bond stress, slip and bond stiffness.

  • PDF

Determinants of Corporate Bond Yield: Empirical Evidence from Indonesia

  • MEGANANDA, Danthi;ENDRI, Endri;OEMAR, Fahmi;HUSNA, Asmaul
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.1135-1142
    • /
    • 2021
  • This study aims to examine the factors that determine bond yields in infrastructure companies listed on the Indonesia Stock Exchange. The research sample used 31 bonds issued by the company during the 2015-2019 period. The data analysis method to estimate the determinant of bond yield uses multiple regression models. The results prove that the increase in the coupon rate causes bond yields to increase, while the inflation rate has the opposite effect of decreasing bond yield. Interest rate, exchange rate, duration, and bond rating variables cannot affect the bond yield. The results of this study imply that investors will be interested in investing in bonds with better yields if the company has to set a higher coupon rate, especially in economic conditions that experience low inflation rates. Interest rates and exchange rates as macroeconomic variables have not been considered by investors in purchasing bonds. Bond characteristic factors, namely, the duration and rating of the bonds, are considered less important factors in bond investment decisions because they are more oriented towards getting higher yields. Therefore, further research needs to be explored further related to the behavior of Indonesian bond investors who may have different characters from investors in other countries.

Concrete-steel bond-slip behavior of recycled concrete: Experimental investigation

  • Ren, Rui;Qi, Liangjie;Xue, Jianyang;Zhang, Xin;Ma, Hui;Liu, Xiguang;Ozbakkaloglu, Togay
    • Steel and Composite Structures
    • /
    • v.38 no.3
    • /
    • pp.241-255
    • /
    • 2021
  • In order to study the interfacial bond-slip behavior of steel reinforced recycled concrete (SRRC) under cyclic loading, thirteen specimens were designed and tested under cyclic loading and one under monotonic loading. The test results indicated that the average bond strength of SRRC decreased with the increasing replacement ratio of recycled concrete, whereas the bond strength increased with an increase in the concrete cover thickness, the volumetric stirrup ratio, and the strength of recycled concrete. The ultimate bond strength of the cyclically-loaded specimen was significantly (41%) lower than that of the companion monotonically-loaded specimen. The cyclic phenomena also showed that SRRC specimens went through the nonslip phase, initial slip phase, failure phase, bond strength degradation phase and residual phase, with all specimens exhibiting basically the same shape of the bond-slip curve. Additionally, the paper presents the equations that were developed to calculate the characteristic bond strength of SRRC, which were verified based on experimental results.

An Experimental Study on Concrete Bond Behavior According to Grid Spacing of CFRP Grid Reinforcement (격자형 CFRP 보강재의 격자간격에 따른 콘크리트 부착거동에 대한 실험적 연구)

  • Noh, Chi-Hoon;Jang, Nag-Seop;Oh, Hongseob
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.73-81
    • /
    • 2022
  • Recently, as the service life of structures increased, the load-carrying capacity of deteriorated reinforced concrete, where corrosion of reinforcing bars occurs due to various causes, is frequently decreased. In order to address this problem, many studies on the bond characteristic of FRP (Fiber Reinforced Polymer) bars with corrosion resistance, light weight and high tensile strength have been conducted, however there are not many studies on the bond characteristic of grid-typed CFRP embedded in concrete. Therefore, in order to evaluate the bond characteristics of grid-typed CFRP and its usability as a substitute for steel rebar, a pull-out test is performed using the longitudinal bond length and transverse grid length of the grid-typed CFRP as variables. Through the pull-out test, the bond load-slip curve of the grid-typed CFRP is derived, and the bond behavior is analyzed. The total bond load equation is proposed as the sum of the bond force of the longitudinal bond length and the shear force of the grid in the transverse direction. Also, expressing the area of the bond load-slip curve as total work, the change in dissipated energy with respect to the slip is analyzed to examine the effect of the tranverse grid on the bond force.

Characteristic Properties of Organic Thin Film Surface on Si Semiconductor (XRD 분석과 FTIR 분석에 의한 비정질 박막의 특성 연구)

  • Oh, Teresa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.112-113
    • /
    • 2007
  • $SiO_2$ 절연 박막위에 희석된 PMMA 유기물을 처리하였다. 유기물 처리량에 따른 $SiO_2$ 박막의 $620{\sim}1100\;cm^{-1}$ 영역의 FTIR 스펙트라를 분석한 결과 0.3~0.7%로 PMMA 처리된 박막에서 친핵성 반응이 밀어나는 것을 확인하였으며, 친핵성 반응이 일어나는 박막들에서 누설전류가 적었으며, 절연특성이 우수한 것을 확인하였다.

  • PDF

Bond Stress of the Bar Removed Rust with Concrete (전식녹을 제거한 철근과 콘크리트의 부착응력에 관한 실험적 연구)

  • Choi, Hyo-Seok;Lee, Joo-Il;Ryu, Soo-Hyun;Yu, Ho-Hyun;Kim, Jin-Mu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.1
    • /
    • pp.188-194
    • /
    • 2001
  • A reinforced concrete structure is complex structure that works as one body with bonding role of steel bar and concrete. The bonding action between steel bar and concrete makes possible the compound structure. The transmission of mutual strength of the steel bar with concrete in structure is determined by the bonding characteristic of steel bar and concrete surface. But the efficiency of bonding characteristic of steel bar is Questionable by the corrosion cause by the delay construction term, the wrong management, etc. So this study investigate bonding characteristic of reinforced concrete using pull-out test method which steel bar removed rust and the principal variables of this study are concrete compression strength and the degree of corrosion. The result showed that bonding strength tend to increase when removed rust of steel bar whereas it tend to decrease when not removed rust.

  • PDF

An Experimental Study on the Bond Characteristic of GFRP Bars in PVA Fiber Reinforced Activated Hwangtoh Concrete (PVA 섬유보강 황토 콘크리트에 대한 GFRP 보강근의 부착성능에 관한 실험적 연구)

  • Park, Mi-Rae;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.1
    • /
    • pp.134-141
    • /
    • 2017
  • Many studies have been conducted with respect to the materials to replace the cement in order to reduce the carbon dioxide emissions during the cement production. Activated hwangtoh as cement replacement material goes through calcination process of $850^{\circ}C$. PVA fibers and GFRP bars are used in order to compensate for the cracks of activated hwangtoh concrete(AHC). This paper presents an experimental study investigating the bond characteristic of GFRP bars in PVA fiber reinforced AHC under tensile loads. Experimental results showed that average bond strength factor of specimens with and without PVA fiber was 2.27~2.48 and was not significantly affected by the ratio of PVA fiber andactivated hwangtoh. In addition, as the bond length was increased, the bond strength was reduced.

Experimental Evaluation of Bearing and Bond Strengths in Compression Splices (철근 압축이음에서 지압강도와 부착강도의 실험적 평가)

  • Chun, Sung-Chul;Lee, Sung-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • Compression splices are required for all compression members in almost all of the floors in high-rise buildings. Therefore, a clear understanding of the behavior of compression splices can provide a rational design of compression splices. Tests of compression splices with bearing only and bond only cases were conducted to investigate the component resistance characteristics of compression splices. Test results showed that the circumferential tensile stresses induced by bearing and bond overlapped at the end of the splice length deterred bond and bearing splices from developing target splicing strength when both normal bond and bearing splices were used. In particular, the bearing strength was more significantly reduced than the bond strength since the bearing relied on the limited area near the end of the splice length. However, the strength of the normal splice was always higher than the strength of the bond only or the bearing only case. Consequently, the study results showed that splice strength in compression cannot be improved by means of removing bond or bearing. In addition, the bond strength in bond only splices was nearly same as the bond strength in tension splices and the strength increase of compression splice is attributed to end bearing only characteristic.

An Experimental Study on the Bonding Characteristic of Steel Tubular Joint Connection filled with Fiber Reinforced High Performance Cementeous Grout (섬유보강 고성능시멘트계 그라우트가 적용된 강관 연결부의 부착특성에 대한 실험적 연구)

  • Oh, Hong-Seob;Seo, Gyo;Kim, Sang-Hyeon;Ko, Sang-Jin;Lee, Hyeon-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • This paper deals with the bonding characteristic of grouted joint connections of monopile support structures for offshore wind power facilities. For the integration of pile connection of wind power supporting structure, fiber reinforced high performance cementeous grout was developed and the ultimate compressive strength of it is 125MPa and the direct tensile strength is 7.5 MPa at 7 days. To assess the bond strength of grout filled in pile connection, small scaled direct bond tests under axially loaded was performed and analyzed according the existing guidelines. The fiber volume fraction (0%, 0.5% and 0.9%), aspect ratio of fiber (60 and 80) and the ratio of height to spacing of shear key (0.013 and 0.056) were adopted as the experimental variables. From the test results, the maximum bond strength among the all specimens was 30.8MPa and the bond strength of grouted connection was affected by the ratio of height to spacing of shear key than the fiber volume fraction.

Photochemical Transformation of Chalcone Derivatives

  • Shin, Dong-Myung;Song, Dong-Mee;Jung, Kyoung-Hoon;Moon, Ji-Hye
    • Journal of Photoscience
    • /
    • v.8 no.1
    • /
    • pp.9-12
    • /
    • 2001
  • The photoisomerization behavior of benzylideneacetophenones, known as chalcones, was studied. We synthesized the chalcone derivatives that have ether groups at 4 and 4' positions. Due to the electron donating ability of the ether oxygen, the bond order of the single bond between two phenyl ring of the chalcone strengthened, which eventually increased the rotational barrier of the single bond. The rotational barrier of the single bond is about 20-22 kcal/mole. Thermal recovery of this process took about 1 min. The UV-visible spectra of these chromophores exhibit two characteristic absorption peaks at 276 nm and 340 nm. The relative intensity of the peaks varies depending on the alkyl chain length of the substituent. Photo-irradiation with the 365 nm light monotonously decreases the 340 nm peak. However, the photo-irradiation with 254 nm light induce two competing processes and produced rather complicated absorption profile.

  • PDF