• 제목/요약/키워드: Bond Resisting Force

검색결과 6건 처리시간 0.019초

구조물 보강용 탄소섬유쉬트의 부착특성에 관한 연구 (A Study on the Bond Properties of Carbon Fiber Sheets used for Strengthening Structures)

  • 황진석;김지영;백명종;박형철;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.653-658
    • /
    • 1997
  • Recently, carbon Fiber sheet (CFS) is frequently used for strengthening deteriorated concrete structures. To strengthening damaged structures, the property and characteristic of the bond between CFS and the concrete surface must be understood. The tensile test of single lap shear specimen was performed to study bond strength, bond stress distribution and stress transfer between CFS and concrete surface according to the bond length. Based on the test results, there were ultimate influence length (UIL) in which bond stress was distributed, and ultimate strain reduction ratio (USRR) by which strain was reduced linearly. Bond resisting force (BRF) was estimated by UIL and USRR, and which was compared with ultimate loads. According to the results of comparison, it was shown that ultimate bond strength could be estimated reasonablely by BRF.

  • PDF

부착길이와 복부정착이 CFRP판으로 보강된 RC 보의 휨 보강효과에 미치는 영향 (Effect of Bond Length and Web Anchorage on Flexural Strength in RC Beams Strengthened with CFRP Plate)

  • 박상렬
    • 콘크리트학회논문집
    • /
    • 제14권5호
    • /
    • pp.645-652
    • /
    • 2002
  • 본 논문은 탄소 FRP 판을 이용한 철근 콘크리트 보의 휨 보강효과와 거동에 대한 연구이다. 본 연구에서의 실험인자로는 휨보강 탄소 FRP 판의 부착길이와 탄소 FRP 쉬트의 복부정착 길이이다. 시험보는 탄소 FRP 판으로 인장면에 부착하여 휨 보강하고 FRP 판을 탄소 FRP 쉬트로 복부에 정착하였다. 일반적으로 복부정착이 없는 휨 보강된 보들의 파괴형태는 횡방향 주철 근을 따라 발생한 콘크리트 덮개 박리파괴를 나타내었다. 반면, 탄소 FRP 쉬트로 복부 정착된 휨 보강 보들은 CFRP 파단파괴 후 콘크리트 경계면 전단 박리파괴를 나타내었다. 보강된 보들의 극한하중과 극한처짐은 FRP 판의 휨 부착길이의 증가에 따라 증가하였다. 또한, 휨 보강된 보들은 FRP 쉬트의 복부정착 길이의 증가에 따라 극한하중과 극한처짐 값이 증가하였다. 특히, 복부 정착한 보들은 최대 극한하중에 도달한 후에도 상당한 극한하중 지지능력을 상당한 극한 처짐 시까지 유지하였다. 시험보의 길이에 걸친 FRP 판의 변형률 분포는 휨 모멘트도의 모양과 거의 유사하여 전단지간에서 일정한 전단응력 분포를 가정할 수 있었다. 전지간을 휨 보강한 보에 있어서는 콘크리트와 FRP 쉬트에 의한 경계면에서의 극한전단 저항강도는 복부정착 길이가 늘어남에 따라 증가하였다. 전단 저항강도 중에서 본 실험에서 사용한 복부 정착 FRP 쉬트도 일부의 전단 저항강도를 부담하였다.

고강도 횡 보강근을 적용한 RC보의 정량적인 부착강도 평가 (Bond Capacity of U-shaped reinforcement for bond splitting prevention in RC beams)

  • 윤혜선;김영식;양완수;백승철;김길희
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.105-108
    • /
    • 2008
  • 국외적으로 고강도 재료에 대한 연구가 활발히 진행되고 있는 반면 국내에서는 고강도 재료에 대한 연구가 미비한 실정이다. 일반적으로 RC 보의 전단 저항은 보강근의 전단 저항 보강근의 양($p_w$), 항복 강도($f_{wy}$)에 지배적인 영향($p_wf_{wy}$)을 받는다. 따라서 고강도 전단 보강을 사용하는 것으로 전단 보강근의 양을 저감시키는 효과가 있을 것으로 판단된다. 이에 본 연구는 고강도 보강근과 보통 강도 비 폐쇄형 횡 보강근의 혼용을 통한 전단 보강근의 양을 줄여 시공 능률향상과 부착성능 향상을 유도하여 부재내력을 증진하기 위한 실험적 연구를 수행하였다.

  • PDF

CFT 기둥의 비선형 유한요소해석을 위한 개선된 강관-콘크리트 간 부착 모델 개발 (An Improved Bond Slip Model of CFT Columns for Nonlinear Finite Element Analysis)

  • 권양수;곽효경;황주영;김진국;김종민
    • 한국전산구조공학회논문집
    • /
    • 제28권2호
    • /
    • pp.213-220
    • /
    • 2015
  • 본 논문에서는 CFT 구조의 강관과 내부 충전 콘크리트 간 복합거동을 유한요소해석 시 적절하게 반영하기 위해 강관과 콘크리트 간 부착 슬립관계 묘사를 위한 알고리즘을 제시하였다. 내부 충전 콘크리트에 축방향 하중 발생 시, 강관과 콘크리트 간 마찰로 인해 강관으로 하중이 전달되며, 이에 따른 강관 슬립량과 힘의 평형관계를 통해 등가강성을 통해 부착관계를 파악할 수 있다. 실제 원형 CFT 부재의 부착응력 실험을 통해 측정된 수직 및 수평 방향 응력 분포 결과와 제안된 해석 기법을 통해 산정된 응력 분포의 비교를 통해 제안된 해석 기법의 타당성을 검증하였다. 또한 비선형 유한요소해석 시 강관과 콘크리트의 부착 거동 묘사에 따라 CFT 기둥의 거동 특성에 영향을 미치게 되므로 축방향 하중이 작용하는 CFT 부재 실험 결과와 제안된 부착-슬립 모델을 반영한 유한요소해석 결과의 하중-변위 곡선 관계 비교를 통해 제안된 기법의 적합성을 검증하였다.

Ti/Al/STS 클래드재의 접합특성에 미치는 예비 열처리의 영향 (Effect of Pre-Heat Treatment on Bonding Properties in Ti/Al/STS Clad Materials)

  • 배동현;정수정;조영래;정원섭;정호신;강창룡;배동수
    • 대한금속재료학회지
    • /
    • 제47권9호
    • /
    • pp.573-579
    • /
    • 2009
  • Titanium/aluminum/stainless steel(Ti/Al/STS) clad materials have received much attention due to their high specific strength and corrosion-resisting properties. However, it is difficult to fabricate these materials, because titanium oxide is easily formed on the titanium surface during heat treatment. The aim of the present study is to derive optimized cladding conditions and thereupon obtain the stable quality of Ti/Al/STS clad materials. Ti sheets were prepared with and without pre-heat treatment and Ti/Al/STS clad materials were then fabricated by cold rolling and a post-heat treatment process. Microstructure of the Ti/Al and STS/Al interfaces was observed using a Scanning Electron Microscope(SEM) and an Energy Dispersed X-ray Analyser(EDX) in order to investigate the effects of Ti pre-heat treatment on the bond properties of Ti/Al/STS clad materials. Diffusion bonding was observed at both the Ti/Al and STS/Al interfaces. The bonding force of the clad material with non-heat treated Ti was higher than that with pre-heat treated Ti before the cladding process. The bonding force decreased rapidly beyond $400^{\circ}C$, because the formed Ti oxide inhibited the joining process between Ti and Al. Bonding forces of STS/Al were lower than those of Ti/Al, because brittle $Fe_3Al$, $Al_3Fe$ intermetallic compounds were formed at the interface of STS/Al during the cladding process. In addition, delamination of the clad material with pre-heat treated Ti was observed at the Ti/Al interface after a cupping test.

유리 웨브를 사용한 H형 합성보의 내력에 관한 연구 (A Study on Resisting Force of H-Shaped Beam Using Glass Web Plate)

  • 손기상;전창현
    • 한국안전학회지
    • /
    • 제21권3호
    • /
    • pp.73-80
    • /
    • 2006
  • Generally beam design depends on the yielding and maximum strength of each member varying with its section shape. Web plate of H-shape beam has not been substituted with glass plate, because it is known that its strength and heat properties are different and it is limited to substitute the existing steel web with glass element. Ceiling height of each room should be decreased with more than 60-80cm due to the beam. Differently from this condition, glass web beam has a good point to see through it and sunshine can be penetrate into the other size especially when it is installed as of outside wall. And also, it can be safer due to controlling room inside easier, if the strength is applicate. This study is to show some applicability after finding out the properties using the test. The test members with a size of $1,600{\times}200{\times}300{\times}9mm$ being SS41 rolled steel having THK 9mm flange while having 8,10mm and reinforced glass 12mm thickness is bonded with epoxy bond under the condition of temperature $28^{\circ}C$, humidity 50%, bonding power 24Mpa. It is show reinforced glass has 5 times of fracture stress more than the common glass but $50{\sim}150%$ difference between these 2 kinds of glass was shown. Reinforce glass did not support the original upper flange after fracture but the common glass did the upper flange after unloading. Generally reinforced glass is stronger than the common one but the common glass having a part of crack on it, compared with reinforced glass having the overall fracture could be more useful in case of needing ductility.