• Title/Summary/Keyword: Boiling absorption

Search Result 62, Processing Time 0.025 seconds

A Study on The Tracking Resistance and Mechanical strength of Epoxy Composites due to Boiling Absorption (비등에 따른 에폭시 복합체의 내트래킹성과 기계적강도에 관한 연구)

  • 김경민;김탁용;이덕진;강태오;홍진웅;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.165-168
    • /
    • 2000
  • This paper presents the tracking resistance and mechanical strength due to boiling absorption of epoxy resin. The single network structure specimen(E series) formed of epoxy alone and interpenetrating polymer network(IPN) structure specimen(EM series) which epoxy resin was taken as first network and methacrylic acid resin as second network were manufactured. As adding $SiO^2$ filler classified by o[phr], 50[phr] and 100[phr] to those specimens, six kinds of specimens were manufactured and boiled in water during 2, 4, 8, 16, 32 and 64[hours]. As a result, it was confirmed that the tracking breakdown time of E series showed a abrupt decrease with boiling time increasing, but that of EM series was decreasing smoothly. Also, it was verified that the degrading rates of mechanical strength was lowerd according to improvement of adhension strength in case of EM series.

  • PDF

The variation of water absorption rate and DC dielectric breakdown strength of Epoxy composites due to filler content (충진재 함량 변화에 따른 에폭시 복합재료의 흡수율과 직류 절연파괴강도의 변화)

  • Lee, D.J.;Kim, T.Y.;Shin, S.K.;Kim, M.H.;Kim, K.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2349-2351
    • /
    • 1999
  • In this paper, the variable absorption rates and DC dielectric breakdown strength of epoxy composites were measured at boiling absorption condition in order to observe the influences of moisture in out door use. Also, in order to improve withstand voltage properties at moisture absorbtion condition. IPN (interpenetrating polymer network) method which had been already reported, was introduced and the influence was investigated. As a result, it was confirmed that the moisture absorption rate was increased and DC dielectric breakdown strength was degraded with boiling time and filler content increasing. On the other hand, it was confirmed that moisture absorption rate and DC dielectric breakdown strength degrading rate were lowered by the improvement of adhesion strength In IPN specimens.

  • PDF

암모니아/물 흡수식 냉동기의 대향류 판형 재생기의 수치모델

  • 지제환;정은수;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.1034-1041
    • /
    • 2001
  • A numerical model which simulates the flow boiling process of the ammonia/water solution within a plate type generator for ammonia/water absorption refrigerators was developed. The ammonia/water solution flows downward under gravity and the ammonia/water vapor generated by flow boiling flows upward. The heating medium flows counter to the ammonia/water solution. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phases were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the heating medium inlet temperature, the mass flow rate of the heating medium and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators (암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석)

  • Ji, Je-Hwan;Jeong, Eun-Soo;Jeong, Si-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

A Study on the Impulse Breakdown Characteristics of Epoxy Composites due to Water Absorption Aging (흡수열화에 따른 에폭시 복합체의 임펄스 절연파괴특성에 관한 연구)

  • 이덕진;손인환;신성권;김명호;김경환;홍진웅;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.156-159
    • /
    • 2000
  • In this paper, the physical and electrical properties of epoxy composites are investigated at boiling absorption condition to observe the influences of moisture. Also, in order to improve water resistance of matrix resin, IPN method was introduced and the influence was investigated. In order to analyze the basic physical properties of samples, scanning electron microscopy method was utilized, and impulse voltage dielectric strength was measured. As a result, it was verified that, in case of IPN samples, the ratio of moisture absorption was decreased due to the improvement of adhesion strength, and impulse voltage dielectric strength of SN sample was degraded abruptly as boiling time and filler content were increasing, while IPN samples were slowly degraded due to the improvement of adhesion strength.

  • PDF

A Study on the variations of mechanical and electrical property of epoxy composites due to boiling absorption (비등흡수에 의한 에폭시 복합재료의 기계적 특성 및 전기적 특성 변화에 관한 연구)

  • 이덕진;신성권;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.1
    • /
    • pp.53-58
    • /
    • 2000
  • In this paper, the variable mechanical strength and dielectric breakdown strength of epoxy composites were measured at boiling absorption condition in order to observe the influences of moisture in out door use. Also, in order to improve water resistance of matrix resin, IPN(interpenetrating polymer network) method which had been already reported, was introduced and the influence was investigated. As Adding filter(SiO2) classified by o[phr], 50[phr] and 100[phr] to two kinds of matrix resin, six kinds of specimens were manufactured. As a result, it was confirmed that the moisture absorption rate was increased and mechanical strength and dielectric breakdown strength were degraded with boiling time and filler content increasing. On the other hand, it was confirmed that moisture absorption rates were decreased and the degrading rates of mechanical strength and dielectric breakdown strength were lowered according to improvement of adhesion strength in case of IPN specimens.

  • PDF

The variations of AC dielectric breakdown strength of epoxy composites due to boiling absorption (비등흡수에 따른 에폭시 복합체의 교류 절연파괴강도의 변화)

  • 이덕진;김경민;김탁용;손인한;신성권;김경환;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.529-531
    • /
    • 1999
  • In this Paper, the variable dielectric breakdown strengths of epoxy composites were investigated at belling absorption condition in order to observe the influences of moisture in out door use. Also. in order to improve withstand voltage properties at moisture absorbtion condition, IPN(interpenetrating polymer network) method was Introduced and the Influence was investigated. As Adding filler(SiO$_2$) classified by o(phr), 50(phr) and 100[phr] to two kinds of matrix resin, six kinds of specimens were manufactured. As a result, it was confirmed that dielectric breakdown strength wer degraded with boiling time and filer content increasing. But, it was confirmed that dielectric breakdown strength degrading rate were lowered by the Improvement of adhesion strength in IPN specimens.

  • PDF

Pool Boiling Performance of Enhanced Tubes for the Generator of an Absorption Chiller (흡수식 냉동기 재생기용 고성능 전열관의 풀비등 성능)

  • Sim, Yong-Sub;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1684-1691
    • /
    • 2015
  • For performance improvement and compactness, usage of enhanced tube is inevitable. However, studies on enhanced tubes for generator is very limited. In this study, pool boiling tests were conducted for 7 heat transfer tubes. Test range covered pressure 7.38~101.3 kPa and heat flux $20{\sim}40kW/m^2$. Results show that boiling heat transfer coefficient increases as pressure or heat flux increases. Under atmospheric condition, high heat transfer coefficients were obtained for notched fin and low fin tubes(225% and 202% of the 19.0 mm smooth tube, which yielded the lowest heat transfer coefficient). As pressure decreased, high heat transfer coefficients were obtained for a low fin tube(290% and 288% of the 19.0 mm smooth tube at 12.34 and 7.38 kPa).

Electrical Properties and Lifetime Prediction of Epoxy/$SiO_2$Composites with Water Absorption Ageing (흡수열화에 따른 Epoxy/$SiO_2$ 복합체의 전기적 특성 및 수명예측)

  • 김탁용;이덕진;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.9
    • /
    • pp.758-763
    • /
    • 2000
  • Dielectric strength of insulators made of epoxy composites rapidly decreases due to ageing to interfaces between the matric resin and filler particles. The adhesion variation of interfaces caused by moisture absorption also alters electrical properties that are the basic characteristics of insulators, particularly, in outdoor use. In this paper, electrical properties of epox/SiO$_2$composites were investigated at boiling absorption condition to observe the influences of moisture. In order to analyze the basic physical properties of samples, scanning electron microscopy and DC, AC and impulse voltage dielectric strength were measured. Also, the breakdown time of samples was measured under AC 6[kV] applied voltage, and the variation of lifetime was verified by using Weibull distribution function.

  • PDF

A Study on Anatomical and Physical Properties of Imported Woods (외래종목재(外來種木材)의 해부학적(解剖學的) 및 물리적(物理的) 성질(性質)에 대(對)한 연구(硏究))

  • Shim, Chong-Supp;Jo, Jae-Myeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.46-47
    • /
    • 1982
  • 1. The physical and anatomical properties investigated in this study are the ones, which may give more effect on absorption of preservatives, such as variation of annual ring, specific gravity, shrinkage, E.M.C. of desorption and adsorption at 70 percent relative humidity condition, general and minute properties of wood. 2. On this study, the positive effects of wood structure, in particular, the appearances of tyloses in vessel element upon the absorption of creosote were observed. 3. Thirteen percent sodium chloride solution treatment and boiling hot water treatment have shown poor results to improve the preservative absorption characteristics of tested species however, some slight difference between treated and control could be seen. (see Tables 6 and 7).

  • PDF