• 제목/요약/키워드: Boiler Modeling

검색결과 44건 처리시간 0.024초

발전소 운전감시 및 고장진단을 위한 계측기기 신호의 전처리 기법에 관한 연구 (An Advanced Instrumentation Signal Analyzing Technique for Automated Power Plant Monitoring and Fault Diagnosis)

  • 장태규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.450-453
    • /
    • 1996
  • This research presents a new method of detecting and diagnosing faults of a power plant. Detection of characteristic wave patterns from multichannel instrumentation signals forms the basis of the proposed approach. The dynamics of 500MW drum-type boiler (Boryung coal-fired plant unit #1 and #2) and its control systems are modeled and simulated to generate diverse operation patterns and fault situations and to utilize them for the development of the fault detection algorithms. The results of the boiler system modeling and simulations show a fairly high agreement when compared with some of the actual plant performance test data.

  • PDF

산업용 보일러의 질소산화물 제어를 위한 SNCR 적용 연구 (Study of SNCR Application to Industrial Boiler for NOx Control)

  • 신미수;김혜숙;장동순
    • 대한환경공학회지
    • /
    • 제27권3호
    • /
    • pp.286-292
    • /
    • 2005
  • 본 연구는 향후 산업적으로 질소산화물 규제가 중요한 문제로 대두될 만한 산업용 보일러를 대상으로 수행하였다. 일반적으로 SNCR 방법의 산업용 보일러로의 적용은 혼합을 위한 충분한 체류시간을 제공하지 못한다는 점에서 적합하지 않은 것으로 알려져 있다. 본 연구의 목적은 SNCR 장치의 산업용 보일러 적용가능성을 조사하기 위한 것이다. 구체적으로 연료로 중유를 사용하는 시간당 스팀 발생량 40톤 규모의 산업용 보일러를 연구 대상으로 하였다. 사업용 보일러의 수치 해석을 위한 3-D 직교좌표계 프로그램에는 난류 유동, 난류 연소반응, NOx의 생성과 환원제와의 반응을 통한 소멸반응 등을 포함하고 있다. 또한 개발된 코드에는 Lagrangian 방법에 의한 입자궤적 프로그램이 포함되어 있고, 주입구에서 접선방향으로의 선회효과를 계산에 의해 고려하였다. 선회버너 효과를 고려한 결과 단화염이 생성되었으며 NOx 환원반응에 적합한 온도 영역의 증가로 인해 NOx 제거효율도 향상되었다. 실험결과와의 비교를 통하여 프로그램을 검증하였으며, 계산결과 혼합용 공기 주입을 통한 환원제와의 혼합 향상을 통해서 SNCR 방법의 산업용 보일러 적용가능성을 확인하였다.

도시 대기오염물중 다환방향족 탄화수소의 배출원 규명을 위한 화학물질 수지모델의 적용 (Application of chemical Mass Balance Model for the Source Apportionment of Polynuclear Aromatic Hydrocarbons in Urban Atmosphere)

  • 구자공;서영화
    • 한국대기환경학회지
    • /
    • 제8권4호
    • /
    • pp.229-239
    • /
    • 1992
  • A receptor model application was performed by using a chemical mass balance (CMB) model to identify and apportion the specific source of airborne organic pollutants, particularly polynuclear aromatic hydrocarbons (PAHs). Source profiles of PAHs produced from the combustion of fossil fuels for CMB modeling were prepared by measuring them in emission gases. The emission sources which were examineed for the development of PAH source profiles are a coal-fired furnace using Yontan, a bunker-C iol heating boiler, and gasoline-and diesel engine automobiles. The ambient concentrations of PAHs were determined at four sites in Daejon city in 1991 with a seasonal variation. Wintertime air samples contained more extractable organic matter than summertime samples. The results of CMB modeling were various depending on the sampling sites and seasons, but the emission from bunker-C oil heating boliers was the predominant factor to affect local air quality throughout the year.

  • PDF

연소 또는 소각 과정에서 발생하는 배기가스의 폐열 회수 설계 방법에 관한 연구 (Study on the Heat Recovery Design Methods for the Flue Gas from Combustion and Incineration Processes)

  • 이찬;정봉진
    • 청정기술
    • /
    • 제5권2호
    • /
    • pp.53-61
    • /
    • 1999
  • 대형 산업용 환경폐기물 처리 및 열병합 플랜트의 연소 및 소각 공정 후 발생하는 배기가스의 폐열회수장치 설계 방법을 제시하였다. 본 연구는 폐열회수장치의 기본 설계 개념을 폐열회수를 위한 보일러와 폐열을 이용한 증기 동력 사이클로 구성되는 것으로 가정하였고, 폐열회수장치에 필요한 각 구성요소들에 대한 모델링 기법과 그에 따른 설계 기준 및 설계 개념을 기술하였다. 또한 본 설계방법을 이용하여, 동일한 배기가스 조건에 대해, 폐열회수 보일러의 작동 압력 및 폐열회수 열교환기 설계에 따라 폐열회수장치의 열성능이 어떻게 변화되는지를 검토하였다.

  • PDF

TRNSYS를 이용한 Borehole 방식 태양열 계간축열 시스템의 성능에 관한 연구 (A Study on Performance of Seasonal Borehole Thermal Energy Storage System Using TRNSYS)

  • 박상미;서태범
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.37-47
    • /
    • 2018
  • The heating performance of a solar thermal seasonal storage system applied to a glass greenhouse was analyzed numerically. For this study, the gardening 16th zucchini greenhouse of Jeollanam-do agricultural research & extension services was selected. And, the heating load of the glass greenhouse selected was 576 GJ. BTES (Borehole Thermal Energy Storage) was considered as a seasonal storage, which is relatively economical. The TRNSYS was used to predict and analyze the dynamic performance of the solar thermal system. Numerical simulation was performed by modeling the solar thermal seasonal storage system consisting of flat plate solar collector, BTES system, short-term storage tank, boiler, heat exchanger, pump, controller. As a result of the analysis, the energy of 928 GJ from the flat plate solar collector was stored into BTES system and 393 GJ of energy from BTES system was extracted during heating period, so that it was confirmed that the thermal efficiency of BTES system was 42% in 5th year. Also since the heat supplied from the auxiliary boiler was 87 GJ in 5th year, the total annual heating demand was confirmed to be mostly satisfied by the proposed system.

고정 튜브시트를 갖는 수평형 열교환기의 등가 모델링을 이용한 튜브 건전성 평가 (Evaluation of Integrity of the Tubes in the Horizontal Fixed Tubesheet Heat Exchanger by Using Equivalent Modeling)

  • 전윤철;김태완;정동관
    • 대한기계학회논문집A
    • /
    • 제26권1호
    • /
    • pp.179-187
    • /
    • 2002
  • Finite element analysis was performed to evaluate the integrity of the tubes in the fixed tubesheet of horizontal type heat exchanger under operating condition. For the finite element analysis of the heat exchanger, tubes and tubesheets were equivalently modeled with concentroidal hexagonal columns and solid plates having equivalent properties for the convenience of finite element modeling, respectively. Load combination of tube pressure and thermal expansion most likely to precipitate possible failure of the tubes was selected and applied to the finite element analysis. The compressive stresses of the tubes were calculated based on displacements of each tube, which were obtained from anile element analysis. Finally, the maximum tube stress was compared with the design criterion of ASME Boiler and Pressure Vessel Code Section VIII.

Thermodynamic model of one of the super heaters and the related spray in the Nekka power plant and Presenting SCO method to control boiler temperature

  • Zalloi, Mehdi;Barghandan, Saeed;Badamchizadeh, M.A.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.129-133
    • /
    • 2005
  • In this paper, first the thermodynamic model is presented to one of the super heaters and sprays of the Nekka power plant and then its unknown parameters are identified according to the registered data of the power plant. SCO control method is introduced to control the external steam temperature of super heater. Finally the conventional method in power plant for controlling external steam temperature of super heater is compared with new method and their performances are presented..

  • PDF

COMPUTER AIDED SCHECULING MODEL OF MATERIALS HANDSLING IN CHEMICAL ANALYSIS FLOOR

  • Fujino, Yoshikazu;Motomatu, Hiroyoshi;Kurono, Shigeru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.31-34
    • /
    • 1995
  • The automated chemical analysis shop floor are developed for the environmental pollution problems in our chemical analysis center. This shop floor have the several equipments include weight, pour, dry, heater, boiler, mixture, spectroscopy etc. And the material handling components are made up by the stored stack, conveyore, turntables, robot etc. Computer simulation has been an important tool for these complete design problem. We have designed the arangement of chemical equipments and material flow systems by using the simulator "AutoModII". "AutoMoII" is one of the advanced simulator, CAD-like drawing tools with a powerful, engineering oriented language to model control logic and material flow. The result is the modeling of the chemical analysis system in accurate, three dimensional detail. We could designed the set able layout and scheduling system by using the AutoMoII simulator. AutoMoII simulator.

  • PDF

Derivation of TMA Slagging Indices for Blended Coals

  • Park, Ho Young;Baek, Se Hyun;Kim, Hyun Hee;Park, Sang Bin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.127-131
    • /
    • 2017
  • The present paper describes the slagging field data obtained with the one-dimensional process model for the 500 MW tangentially coal fired boiler in Korea. To obtain slagging field data in terms of thermal resistances [$m^2{\cdot}^{\circ}C/kW$], a number of plant data were collected and analyzed with the one-dimensional modelling software at 500 MW full load. The slagging field data for the primary superheater were obtained for six coal blends, and compared with two TMA (Thermo-Mechanical analyzer) slagging indices and the numerical slagging index, along with the conventional slagging indices which were modified with the ash loading. The advanced two TMA indices for six blended coals give a good slagging tendency when comparing them with the slagging field data, while the modified conventional slagging indices give a relatively poor agreement.

석탄화력발전소 연소계통의 해석을 위한 모델개발 (Development of Analysis Model for Combustion System of Coal Fired Power Plant)

  • 정환주;박용섭;김성환;장영학;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.392-394
    • /
    • 2001
  • Coal power plants are large, non-linear systems with numerous interactions between its component parts. In the analysis of such complex systems, dynamic simulation is recognized as a powerful method of keeping track of the myriad of interactions. This paper shows and discusses the developed analysis model, such as the forced draft fan the primary air fan, the furnace and burner system, air preheater and induced draft fan, etc. in accordance with BMCR condition of boiler using the Modular Modeling System(MMS) software.

  • PDF