• Title/Summary/Keyword: Boil-Off Ratio

Search Result 24, Processing Time 0.029 seconds

Boil-off Loss Ratio of Cocoon Shell as a Selection Criterion in the Newly Developed Bivoltine Silkworm (Bombyx mori L.) Hybrids

  • Seetharamulu, J.;Seshagiri, S.V.;Raju, P.J.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.26 no.1
    • /
    • pp.13-21
    • /
    • 2013
  • Boil-off loss ratio is one of the most important economic traits to be considered during the course of silkworm breeding. The boil-off loss ratio varies among the breeds and seasons. The present study was undertaken with 5 oval and 5 peanut breeds and twenty five hybrids involving these parents to select the promising hybrids with desired boil-off loss ratio. Accordingly, studies were undertaken to estimate the heterosis and heterobeltiosis. It was observed that majority of the hybrids revealed negative heterosis for boil-off loss ratio which is desirable. Based on the heterosis and heterobeltiosis, among all the hybrids, the hybrid APBRO5 ${\times}$ APBRD5 exhibited highest negative heterosis for boil-off loss ratio and also exhibited highest EI value (64.5) for the quantitative and qualitative traits. Based on the hybrids performance, boil-off loss ratio, heterosis and heterobeltiosis and evaluation index, the hybrids viz. APBRO5 ${\times}$ APBRD5, APBRO1 ${\times}$ APBRD1 and APBRO3 ${\times}$ APBRD4 were identified for commercial exploitation.

Studies on Boil-off Loss Ratio in the Cocoon Shells of Multivoltine${\times}$Bivoltine Hybrids of Silkworm, Bombyx mori L.

  • Rao, D.Raghavendra;Singh, Ravindra;Premalatha, V.;Sudha, V.N.;Kariappa, B.K.;Dandin, S.B.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.8 no.1
    • /
    • pp.101-106
    • /
    • 2004
  • The process of removal of gummy proteinous material sericin from silk is commonly called as degumming loss or boil-off loss ratio. In the present study, the boil-off loss ratio in the cocoon shells of twelve multivoltine${\times}$bivoltine hybrids and their parents were analysed. Inheritance pattern of boil-off loss ratio was analysed in crosses involving high and low boil-off loss parents, F$_1$s, F$_2$s and back-crosses by parent off spring regression analysis. Heterosis and heterobeltiosis was also analysed for this character, Highly significant (P>0.01) variations were observed in eight out of ten multivoltine and two out of five bivoltine parents indicating the presence of genetic variation in the expression of boil-off loss ratio. Among F$_1$ hybrids, ten hybrids expressed significant (P>0.01) variations when compared with control hybrid PM${\times}$NB$_4$D$_2$. Significant negative heterosis was expressed in three multi ${\times}$ bi hybrids viz., BL67${\times}$CSR$_{101}$, 96A${\times}$CSR$_{19}$ and 96C${\times}$CSR$_{19}$, which is desirable for this character, whereas expression of heterobeltiosis was significant only with one hybrid, 96C${\times}$CSR$_{18}$ in desired direction. Studies on inheritance pattern showed that the character is heritable and contribution percentage of female and male in the ratio of 50.9: 49.1 and it appears that both the parents are influencing in the expression of boil-on loss ratio in silkworm. Based on the overall performance and evaluation by multiple trait evaluation index and also considering the expression of the boil-off loss ratio three hybrids vix., BL67 ${\times}$ CSR$_{101}$, 96A${\times}$CSR$_{19}$ and 96C${\times}$CSR$_{18}$ were found superior and recommended for commercial exploitation.n.ion.n.

Studies on the Calculating Method of Conditioned Weight by dry Weight after Boiling-off in Raw Silk (생사정량산정에 있어서 연감후 무수량의 도입에 관한 연구)

  • 김수현;이상근;김영진
    • Journal of Sericultural and Entomological Science
    • /
    • v.13 no.1
    • /
    • pp.73-78
    • /
    • 1971
  • The purpose of this study is to find out the method of conditioned weight test by which the dealing weight of raw silk can be calculated from true fiber in order to do the fair trading. The results of this study were as follows. 1. It is more reasonable than the current test that conditioned weight as a dealing weigh can be calculated by boil-off and moisture regain which is a percentage of boil-on and moisture regain to net weight. Because the boil-off and moisture regain can show directly the amount of true fiber and reproductibility in raw silk. In this study the boil-off and moisture regain is to take dry weight after boiling-off from net weight. 2. To calculate the conditioned weight from boil-of and moisture regain it would be proper that the standard additional ratio is 44 per cent of dry weight after boiling-off. 3. Boil-of percent of the sizing sample skein used in the size test did not show a statistical significance comparing with the boil-off percent of sample skeins (24 skeins) which may represent that of a lot. To observe this result boil-off percent of the sizing sample skein may represent that of a lot. 4. In Korea if conditioned weight test substitute for test of boil-off and moisture regain, we make a profit of two billion won in a year at the current market-price.

  • PDF

A Study on the Computation of Hull Temperature Distribution and Boil off Ratio of MRV Type LNG Carrier (MRV형 LNG선의 선체온도분포 및 증발률 산정에 관한 연구)

  • 천병일;김용모;김경근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.986-996
    • /
    • 1994
  • Insulation system of LNG carrier has made important roles such as maintaining a proper Boil off Ratio(BOR) for the cargo and avoiding the excessive low temperature of the adjacent inner hull beyond the permissible limit. At the same time, safety and economy of the LNG transportation by the ship are connected with the performance of the insulation system. Also, thermal insulation system of LNG carrier is one of the most advanced technique with the structure analysis of tank, welding and assembling. In this study a computer program is developed to calculate the hull temperature distribution and BOR, which are important factors in thermal design for the Moss Rosenberg Verft spherical tank type LNG carrier. Detailed results for hhull temperature distribution close to LNG tank, BOR and the thickness effect of insulation material are reported in this paper in the range of standare design sea condition.

Correlation Coefficient Studies on Certain Quantitative Traits in the Silkworm, Bombyx mori L.

  • Begum, A.Naseema;Yamamoto, T.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.1
    • /
    • pp.44-52
    • /
    • 2002
  • To understand the relationship among different quantitative traits, correlation studies were performed by utilizing eighty-eight inbred strains of silkworm, Bombyx mori L. on twelve economic characters. Analysis resulted in correlation of 5th instar period with total larval period (r = 0.7882), cocoon weight with shell weight (r = 0.8326), shell weight with shell ratio (r = 0.5067), shell ratio with raw silk % (r = 0.7570), raw silk % with filament length (r = 0.3490), filament size (denier) with reelability (r = 0.3193) and boil-off loss % (r = 0.2792). Negative correlation was observed among filament length with filament size (r = 0.7582) and reelability with boil-off loss % (r = -0.3236). Correlation of different quantitative characters for quality silk production is discussed.

Determination of Boil-Off gas Ratio for the Design of Underground LNG Storage System in Rock Cavern (암반동굴식 지하 LNG 저장 시스템 설계를 위한 기화율의 산정)

  • Chung, So-Keul;Lee, Hee-Suk;Jeong, Woo-Cheol;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.17 no.1 s.66
    • /
    • pp.56-65
    • /
    • 2007
  • A new underground LNG storage concept in the rock mass has been developed by combining underground cavern construction and new ice-ring harrier technologies with the conventional cryogenic insulation system. Technical feasibility of the storage system has been verified through construction and operation of the pilot storage cavern and a full-scale project is expected to start in the near future. One of the most important issues in the LNG storage system is the operational efficiency of the storage to minimize heat loss during a long period of operation due to the cryogenic heat transfer. This paper presents several important results of heat transfer and coupled hydro-thermal analyses by a finite element code Temp/W and Seep/W. A series of heat transfer analyses for full-scale caverns were performed to determine design parameters such as boil-off gas ratio (BOR), insulation thickness and pillar width. The result of the coupled hydro-mechanical analysis showed that BOR for underground storage system remains at about 0.04 %/day during the early stage of the operation. This value could be even much lower when the discontinuities in the rock masses are taken into consideration.

A Helmet-type MEG System with $1^{st}$ order SQUID Gradiometer Located in Vacuum (진공조에 위치한 1차 SQUID 미분계를 이용한 헬멧형 뇌자도 장치의 제작)

  • Yu, K.K.;Kim, K.;Lee, Y.H.;Kim, J.M.
    • Progress in Superconductivity
    • /
    • v.11 no.1
    • /
    • pp.78-82
    • /
    • 2009
  • We have fabricated a helmet type magnetoencephalogrphy(MEG) with a $1^{st}$ order gradiometer in vacuum to improve the signal-to-noise ratio(SNR) and the boil-off rate of liquid helium(LHe). The axial type first-order gradiometer was fabricated with a double relaxation oscillation SQUID(DROS) sensor which was directly connected with a pickup coil. The neck space of LHe dewar was made to be smaller than that of a conventional dewar, but the LHe boil-off ratio appeared to increase. To reduce the temperature of low Tc SQUID sensor and pickup coil to 9 K, a metal shield made of, such as copper, brass or aluminum, have been usually used for thermal transmission. But the metal shield exhibited high thermal noise and eddy current fluctuation. We quantified the thermal noise and the eddy current fluctuation of metal. In this experiment, we used the bobbin which was made of an alumina to wind Nb superconductive wire for pickup coil and the average noise of coil-in-vacuum type MEG system was $3.5fT/Hz^{1/2}$. Finally, we measured the auditory evoked signal to prove the reliability of coil-in-vacuum type MEG system.

  • PDF

Study on the Comparison of New and Used Reliquefaction System of Boil-Off-Gas by LNG Cold Energy (냉열을 이용한 LNG 증발기체 BOG 재액화 신공정과 기존공정에 관한 비교연구)

  • Lee, Dong-Hyuck;Jang, Chang-Bong;Jung, Sang-Yong;Kim, Jung-Hwan;Lee, Heon-Seok;Kim, Bum-Su;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.42-46
    • /
    • 2010
  • BOG(Boil Off Gas) is formed about 0.05 vol%/day from LNG(Liquefied Natural Gas) tanks of LNG receiving terminal. To recycle the BOG using direct contacting, Previously the quantities of LNG and BOG is mixed at the ratio of 11:1 by mass. However simple this process uses, there is the difficulty of processing operation resulted from decrease of using LNG in summer. To complement these shortcomings, Advantages of the process are investigated by comparison of cost and analysis of the indirect contact method using LNG cold energy. It was studied that principles and types of development using LNG cold energy which is abandoned in the carburettor and found how to contact each to find the appropriate cold energy development process. Therefore, in this research, the indirect contact method will be investigated the feasibility of a comparative analysis by using HYSYS.

Heat Transfer Analysis and BOG Estimation of Membrane-Type LNG Cargo during Laden Voyage (멤브레인형 LNG선 Cargo의 만선항해시 열전달 해석 및 BOG 평가)

  • Heo, Jin-Uk;Lee, Young-Ju;Cho, Jin-Rae;Ha, Mun-Keun;Lee, Joong-Nam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.3
    • /
    • pp.393-400
    • /
    • 2003
  • Excessive generation of BOG during the LNG transportation not only causes the severe financial loss but also leads to the unexpected disaster. Therefore, the carrier cargo insulating interior LNG should be carefully designed based upon an accurate heat transfer analysis. However. it is not simple to analyze heat transfer of LNG cargo, because it is in a complex insulation structure and LNG carrier experiences a complicated heat transfer according to various kinds of voyage conditions. In this paper, we carried out the transient finite element heat transfer analysis for a cargo of Mark-111 membrane-type LNG carrier during laden voyage, and we compared heat transfer rates between considering natural convection and considering conduction. For this goal, we developed a PCL program incorporating with a commercial MSC/NASTRAN FEM code.