• Title/Summary/Keyword: Body segments

Search Result 219, Processing Time 0.024 seconds

Fine Structural Modification of Mouse Ovarian Tissue by Irradiation of 6 MeV LINAC Radiation (6 MeV LINAC 방사선 조사에 의한 생쥐 난소조직의 미세구조 변화)

  • Yoon, Chul-Ho;Moon, Myung-Jin
    • Applied Microscopy
    • /
    • v.33 no.2
    • /
    • pp.117-130
    • /
    • 2003
  • This research investigates the fine structural as well as the morphological changes of the mouse ovarian tissue after irradiation of various dose rates of 6 MeV LINAC radiation. The normal structure of the ovarian tissue is consisted of various stages of follicles including primordial and growing follicles, and ovarian stromal connectives. When we observed the ovarian tissues irradiated with a dose rate of 200 cGy/min using light and electron microscopes, granular cells in growing follicles are in irregular shape unlike normal follicles. Small segments of cells scattered in follicular antrum among granular cells. We could observe neutrophils and macrophages around the segments, which means the cells already got in the process of decease owing to the effects radiation. With coincident to the increase of the dose rate of x-ray irradiation as 400 or 600 cGy/min, the mature follicles appeared as an irregular form and the granular cells surrounding oocyte also deformed comparing to their normal counterparts. The granulosa cells within mature follicle are already occurred necrotic change and apoptosis. The nuclei in some cells got so fragmented that the segments formed the shape of a horseshoe or scattered in small and condensed pieces. All the cells at a granular layer irradiated with a dose rate of 600 cGy/min show typical characteristics of apoptosis. The neutrophils involved in inflammatory reaction appear evidently in follicular antrum of growing follicles, and macrophage scattered with residual and apoptotic bodies.

Replication and Sequential Development of Adherent Mycoplasma Pneumoniae Studied by Light and Electron Microscopies (광학(光學) 및 전자현미경기술(電子顯微鏡技術)에 의(依)한 Mycoplasma pneumoniae의 분열(分裂)과 연속분화(連續分化)에 관(關)한 연구(硏究))

  • Kim, C.K.;Pfister, Robert M.
    • Applied Microscopy
    • /
    • v.12 no.2
    • /
    • pp.11-22
    • /
    • 1982
  • The morphological development of Mycoplasma pneumoniae attached to solid surfaces was examined by light and electron microscopies. Critical point drying and carbon replication techniques revealed that during the growth cycle of developing microcolonies, the morphological form coincided with the pH of the culture. M. pneumoniae appeared to have a well defined morphology associated with age of the culture. The organisms were dimorphic, with round cells capable of reproduction and segments consisting of a spindle shaped body with one pointed and one knob-like end. Starting with single cells, there were the following stages in the development of a culture: replication stage through binary fission and segmentation, stage of confluency, and a degeneration stage into rough spherical forms. The round cells appearrd to replicate by binary fission during the lag and early log phases of growth, while spindle segments replicated by segmentation during most of the logarithmic growth. The growth of the filaments and replication of the segments occured at the knob-like ends, showing a type of polarity, and formed a meshwork across the surface. This development could be cycled under favorable growth conditions, but the culture aged and when the conditions became adverse(e.g. pH 6.8 or lower), filamentous cells converted to spherical forms, losing their reproductive capability.

  • PDF

A Numerical Solution Method of the Boundary Integral Equation -Axisymmetric Flow- (경계적분방정식의 수치해법 -축대칭 유동-)

  • Chang-Gu,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.3
    • /
    • pp.38-46
    • /
    • 1990
  • A numerical solution method of the boundary integral equation for axisymmetric potential flows is presented. Those are represented by ring source and ring vorticity distribution. Strengths of ring source and ring vorticity are approximated by linear functions of a parameter $\zeta$ on a segment. The geometry of the body is represented by a cubic B-spline. Limiting integral expressions as the field point tends to the surface having ring source and ring vorticity distribution are derived upto the order of ${\zeta}ln{\zeta}$. In numerical calculations, the principal value integrals over the adjacent segments cancel each other exactly. Thus the singular part proportional to $\(\frac{1}{\zeta}\)$ can be subtracted off in the calculation of the induced velocity by singularities. And the terms proportional to $ln{\zeta}$ and ${\zeta}ln{\zeta}$ can be integrated analytically. Thus those are subtracted off in the numerical calculations and the numerical value obtained from the analytic integrations for $ln{\zeta}$ and ${\zeta}ln{\zeta}$ are added to the induced velocity. The four point Gaussian Quadrature formula was used to evaluate the higher order terms than ${\zeta}ln{\zeta}$ in the integration over the adjacent segments to the field points and the integral over the segments off the field points. The root mean square errors, $E_2$, are examined as a function of the number of nodes to determine convergence rates. The convergence rate of this method approaches 2.

  • PDF

Effect of Tiger Step on Lower Extremities during Uphill Walking (오르막보행 시 타이거스텝 하지 움직임에 미치는 영향)

  • Kang, Jihyuk;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.1
    • /
    • pp.17-23
    • /
    • 2022
  • Objective: The aim of this study was to investigate the effect Tiger-step walking on the movement of the lower extremities during walking. Method: Twenty healthy male adults who had no experience of musculoskeletal injuries on lower extremities in the last six months (age: 26.85 ± 3.28 yrs, height: 174.6 ± 3.72 cm, weight: 73.65 ± 7.48 kg) participated in this study. In this study, 7-segments whole-body model (pelvis, both side of thigh, shank and foot) was used and 29 reflective markers and cluster were attached to the body to identify the segments during the gait. A 3-dimensional motion analysis with 8 infrared cameras and 7 channeled EMG was performed to find the effect of tigerstep on uphill walking. To verify the tigerstep effect, a one-way ANOVA with a repeated measure was used and the statistical significance level was set at α=.05. Results: Firstly, Both Tiger-steps showed a significant increase in stance time and stride length compared with normal walking (p<.05), while both Tiger-steps shown significantly reduced cadence compared to normal walking (p<.05). Secondly, both Tiger-steps revealed significantly increased in hip and ankle joint range of motion compared with normal walking at all planes (p<.05). On the other hand, both Tiger-steps showed significantly increased knee joint range of motion compared with normal walking at the frontal and transverse planes (p<.05). Lastly, Gluteus maximus, biceps femoris, medial gastrocnemius, tibialis anterior of both tiger-step revealed significantly increased muscle activation compared with normal walking in gait cycle and stance phase (p<.05). On the other hand, in swing phase, the muscle activity of the vastus medialis, biceps femoris, tibialis anterior of both tiger-step significantly increased compared with those of normal walking (p <.05). Conclusion: As a result of this study, Tiger step revealed increased in 3d range of motion of lower extremity joints as well as the muscle activities associated with range of motion. These findings were evaluated as an increase in stride length, which is essential for efficient walking. Therefore, the finding of this study prove the effectiveness of the tiger step when walking uphill, and it is thought that it will help develop a more efficient tiger step in the future, which has not been scientifically proven.

The Kinematic Factors of Physical Motions During Air Pistol Shooting

  • Kim, Min-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.197-204
    • /
    • 2016
  • Objective: The purpose of this study was to analyze the kinematic factors of motion during air pistol shooting. Method: This study aimed to investigate changes in forces during movement and determine the factors that affect changes in force during the first, middle, and last periods of shooting an air pistol. Two ground reaction force systems (force platform), SCATT (a shooting training system), and EMG (electromyogram) to measure the action potentials in the muscles of the upper body were used in this study. Four university air pistol players (age: 19.75 years, height: 175.50 cm, body mass: $69.55{\pm}11.50kg$, career length: $6.25{\pm}6years$) who are training to progress to a higher rank were enrolled. Results: In terms of the actual shooting results, the mean score in the middle section was $42.48{\pm}1.74$ points, higher than those in the first and the last periods when using SCATT. The gunpoint moved 13.48 mm more vertically than horizontally in the target trajectory. With respect to action potentials of muscles measured using EMG, the highest action potentials during the aiming-shooting segments, in order higher to lower, were seen in the trapezius (intermediate region), trapezius (superior region), deltoid (lateral), and triceps brachii (long head). The action potentials of biceps brachii and brachioradialis turned out to be high during grasping motion, which is a preparatory stage. During the final segment, muscle fatigue appeared in the deltoid (lateral), biceps brachii (long head), brachioradialis, and trapezius (intermediate region). In terms of the ground reaction force, during the first period of shooting, there was a major change in the overall direction (left-right $F_x$, forward-backward $F_y$, vertical $F_z$) of the center of the mass. Conclusion: The development and application of a training program focusing on muscle groups with higher muscle fatigue is required for players to progress to a higher rank. Furthermore, players can improve their records in the first period if they take part in a game after warming up sufficiently before shooting in order to heighten muscle action potentials, and are expected to maintain a consistent shooting motion continuously by restoring psychological stability.

Effects of probiotic supplement (Bacillus subtilis and Lactobacillus acidophilus) on feed efficiency, growth performance, and microbial population of weaning rabbits

  • Phuoc, Thanh Lam;Jamikorn, Uttra
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.2
    • /
    • pp.198-205
    • /
    • 2017
  • Objective: This study aimed to investigate the effects of single or/and double strains of probiotic supplement on feed efficiency, growth performance, and microbial population in distal gastrointestinal tract (GIT) of weaning rabbits. Methods: Sixty-four weaning (28 days old) New Zealand White rabbits were randomly distributed into four groups with treatments including: basal diet without probiotic supplement (control) or supplemented as follows: $1{\times}10^6cfu/g$ B. subtilis (BS group), $1{\times}10^7cfu/g$ L. acidophilus (LA group), or $0.5{\times}10^6cfu/g$ B. subtilis plus $0.5{\times}10^7cfu/g$ L. acidophilus (BL group). During the research, the male and female rabbits were fed separately. Body weight of the rabbits was recorded at 28, 42, and 70 d of age. Results: There was an increase (p<0.05) in body weight gain for the LA group at 42 d. Rabbits fed BL responsed with a greater growth (p<0.05) and better feed conversion ratio (p<0.05) than those fed with no probiotic. Digestibility coefficients of dry matter, organic matter, crude protein, neutral detergent fiber, and gross energy were higher (p<0.05) in LA and BL groups than those in the control group. Male rabbits had higher (p<0.05) Bacilli spp. and Coliformis spp. in the ileum than female rabbits. Rabbits supplemented with BS had greater (p<0.05) numbers of bacilli in all intestinal segments than those receiving no probiotic, whereas intestinal Lactobacilli populations were greater (p<0.001) in the LA and BL diets compared to control. Average intestinal coliform populations were lowest (p<0.05) in the rabbits supplemented with LA as compared to those fed the control and BS. Conclusion: Supplementation of L. acidophilus alone or in combination with B. subtilis at a half of dose could enhance number of gut beneficial bacteria populations, nutrient digestibility, cecal fermentation, feed efficiency, and growth performance, but rabbits receiving only B. subtilis alone were not different from the controls without probiotic.

A Study on the Positioning Strategy of the Fashion Underwear Market (패션내의류 시장의 포지셔닝 전략에 관한 연구)

  • 백민숙;김문숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.1
    • /
    • pp.29-40
    • /
    • 1998
  • This study is to develope positioning strategy of fashion underwear market through the perceptual map which can analyze the psychological positioning of the existing fashion underwear brand. A positive study has been made on 176 women in their teens and twenties who live in the Seoul area through questionaire. The collected data was analyzed with Multidimensional Scaling Method, Conjoint Analysis and Cluster Analysis and so on. The results of analyzing the competitive relationships for attributes and the ideal points are as follows: The consumers groups are divided into three market segments on the basis of the ideal points about fashion underwear attributes. $\ulcorner$calvin Klein$\lrcorner$ evaluated excellent in design and color, brand and function attributes, and also appealed well to the segment market 2. $\ulcorner$calvin Klein$\lrcorner$ has good positioning at the fashion underwear market, and as well as the possibility of growth. $\ulcorner$Body Guard$\lrcorner$ appealed well in segment market 1 which highly valued the material and price attributes and $\ulcorner$Body Guard$\lrcorner$ competes with $\ulcorner$Benetton Undercolor$\lrcorner$ in this market. $\ulcorner$Hunt Innerwear$\lrcorner$ has possibilitiy to be appealed in segment market 3. Finally, it is necessary for each fashion underwear company to analyze and develope the segment market 3. Each company has to develope the brand that can appeal in the segment market 3 in which function was highly valued, and has better to make strategies that develope more functional products like sports underwear, bodysuit and bodywear and so on.

  • PDF

The Change of Adjacent Segment and Sagittal Balance after Thoracolumbar Spine Surgery

  • Kim, Kang-San;Hwang, Hyung-Sik;Jeong, Je-Hoon;Moon, Seung-Myung;Choi, Sun-Kil;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.5
    • /
    • pp.437-442
    • /
    • 2009
  • Objective : To characterize perioperative biomechanical changes after thoracic spine surgery. Methods : Fifty-eight patients underwent spinal instrumented fusions and simple laminectomies on the thoracolumbar spine from April 2003 to October 2008. Patients were allocated to three groups; namely, the laminectomy without fusion group (group I, n = 17), the thoracolumbar fusion group (group II, n = 27), and the thoracic spine fusion group (group III, n = 14). Sagittal (ADS) and coronal (ADC) angles for adjacent segments were measured from two disc spaces above lesions at the upper margins, to two disc spaces below lesions at the lower margins. Sagittal (TLS) and coronal (TLC) angles of the thoracolumbar junction were measured from the lower margin of the 11th thoracic vertebra body to the upper margin of the 2nd lumbar vertebra body on plane radiographs. Adjacent segment disc heights and disc signal changes were determined using simple spinal examinations and by magnetic resonance imaging. Clinical outcome indices were determined using a visual analog scale. Results : The three groups demonstrated statistically significant differences in terms of angle changes by ANOVA (p<0.05). All angles in group I showed significantly smaller angles changes than in groups II and III by Turkey's multiple comparison analysis. Coronal Cobb's angles of the thoracolumbar spine (TLC) were not significantly different in the three groups. Conclusion : Postoperative sagittal balance is expected to change in the adjacent and thoracolumbar areas after thoracic spine fusion. However, its prevalence seems to be higher when the thoracolumbar spine is included in instrumented fusion.

3D Character Motion Synthesis and Control Method for Navigating Virtual Environment Using Depth Sensor (깊이맵 센서를 이용한 3D캐릭터 가상공간 내비게이션 동작 합성 및 제어 방법)

  • Sung, Man-Kyu
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.827-836
    • /
    • 2012
  • After successful advent of Microsoft's Kinect, many interactive contents that control user's 3D avatar motions in realtime have been created. However, due to the Kinect's intrinsic IR projection problem, users are restricted to face the sensor directly forward and to perform all motions in a standing-still position. These constraints are main reasons that make it almost impossible for the 3D character to navigate the virtual environment, which is one of the most required functionalities in games. This paper proposes a new method that makes 3D character navigate the virtual environment with highly realistic motions. First, in order to find out the user's intention of navigating the virtual environment, the method recognizes walking-in-place motion. Second, the algorithm applies the motion splicing technique which segments the upper and the lower motions of character automatically and then switches the lower motion with pre-processed motion capture data naturally. Since the proposed algorithm can synthesize realistic lower-body walking motion while using motion capture data as well as capturing upper body motion on-line puppetry manner, it allows the 3D character to navigate the virtual environment realistically.

A Study on Motion and Position Recognition Considering VR Environments (VR 환경을 고려한 동작 및 위치 인식에 관한 연구)

  • Oh, Am-suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.12
    • /
    • pp.2365-2370
    • /
    • 2017
  • In this paper, we propose a motion and position recognition technique considering an experiential VR environment. Motion recognition attaches a plurality of AHRS devices to a body part and defines a coordinate system based on this. Based on the 9 axis motion information measured from each AHRS device, the user's motion is recognized and the motion angle is corrected by extracting the joint angle between the body segments. The location recognition extracts the walking information from the inertial sensor of the AHRS device, recognizes the relative position, and corrects the cumulative error using the BLE fingerprint. To realize the proposed motion and position recognition technique, AHRS-based position recognition and joint angle extraction test were performed. The average error of the position recognition test was 0.25m and the average error of the joint angle extraction test was $3.2^{\circ}$.