• Title/Summary/Keyword: Body scan data

Search Result 218, Processing Time 0.023 seconds

3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 - (The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner -)

  • 박선미;남윤자
    • 한국의상디자인학회지
    • /
    • 제14권1호
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

인체 형상 데이터를 이용한 실버 여성 3차원 체형 연구 (Body Shapes of Aged Women Applying 3D Body Scan Data)

  • 김수아;최혜선
    • 복식문화연구
    • /
    • 제17권6호
    • /
    • pp.1099-1111
    • /
    • 2009
  • The purpose of this study is to classify body shapes of aged women by using 3D body scan data. For the body shape analysis and classification, 3D body scan data of 270 aged women were used, and 16 main measurements consisting of a human body were used to conduct factor analysis, cluster analysis and discriminant analysis. The analysis were performed on all 'the method using the absolute value', 'the method using index of height and weight', and 'the method using index of height', and according to the classification results, the method which categorizes body shapes best in terms of their shapes was adopted. As the factor analysis result using the numerical value of height to categorize the body shapes of the aged women, factor 1 was the thickness and width for the height, factor 2 was the height of the upper part of the body for the height, factor 3 was the height of hips for the height, and factor 4 was the height of belly for the height. When the body shapes were categorized with the deducted factors as variables, they were divided into two types. Type 1 was a short and fat body shape($\blacksquare$ type) and 55.6% of the subjects were of this type. Type 2 was for the body shape whose vertical height, including weight, was long but all kinds of width and thickness were small, that is, tall and thin body shape($\blacksquare$ type), and 44.4% of the aged women were in this case.

  • PDF

미국 여성의 3차원 바디 스캔 이미지 분석을 통한 상반신 측면체형 분류 (Classification of Side Somatotype of Upper Lateral Torso Analyzing 3D Body Scan Image of American Females)

  • 나현신
    • 복식
    • /
    • 제57권4호
    • /
    • pp.9-17
    • /
    • 2007
  • Somatotype is human body shape and physique type which can be classified not only by the size, but also by the shape or posture of the body. Postural variations in the alignment of the back, shoulder, and neck can have an adverse effect on the fit of garments designed to hang from the shoulders. There have been some previous studies about the lateral upper torso by analyzing photographic measurements. In this study, 3D body scan images were used to classify the side somatotype of upper lateral method even though they are major data in the classification of upper torso. This study focused on following objective.; 1) To apply new and developing technology into the apparel industry analyzing 3D body scan images. 2) To classify upper laterla torso using the data through the new improver technology, 3D body scanner. 3) To propose basic materials for well fitted garments for each type of figure. The test subjects for this study were two hundreds nine female aged 19 years and up who were recruited in Cornell university body scan research team. Seventeen Variables(12 angles, 5 lengths) out of 3D body scan data were measured based on these landmarks and applied to analyze. The result of factor analysis indicated that 6 factors were extracted through factor analysis and orthogonal rotation by the method of Varimax and those factors comprise 62.5% of total variance. And the somatotype of upper body is classified into 3 types of figures according to cluster analysis; Bent forward posture, Straight posture, Swayback posture. Future study could be addressed about the somatotype of body by the age group based on the large database with wide variety of age.

3차원 인체 스캔 데이터를 활용한 중년 남성 정면 비대칭 체형 특성 분석 (Analysis of Middle-aged Men's Frontal Body Shape Asymmetry using 3D Body Scan Data)

  • 이민선;김동은
    • 한국의류학회지
    • /
    • 제47권3호
    • /
    • pp.511-530
    • /
    • 2023
  • This study aims to analyze middle-aged men's frontal body shape asymmetry by measuring the left and right body dimensions and angles of 388 middle-aged men aged 40 to 59 using 3D body scan data and comparing the measured values. The study also compares the measured values of width, height, and angle and their relationships using Size Korea's anthropometric measurement and posture index of the New York Posture Rating Scale. The results confirm that the asymmetric shape characteristics of the upper and lower body appear differently. In addition, the asymmetrical characteristics between the upper and lower body differed, indicating that the close parts of the body affect each other. Similar to the difference in the left and right frontal body shapes and the average angle distribution, the asymmetrical upper and lower body characteristics also are found to be dissimilar when the correlations are examined. In contrast, there is no asymmetry in the width, height, and angle considering the age and BMI groups. Finally, the study classifies three body types and identifies their asymmetric characteristics. Overall, this study contributes primary data for further research on pattern production for asymmetric and unique body types and the development of customized apparel products.

3차원 인체 스캔 데이터를 활용한 Hip-hugger 의류용 벨트 패턴 설계 (Belt Pattern Making for Hip-hugger garment using 3D Body Scan Data)

  • 박순지;최신애
    • 한국의류산업학회지
    • /
    • 제10권5호
    • /
    • pp.652-659
    • /
    • 2008
  • This study was designed to testify the possibility and devise the method to manipulate the 3D body scan data to produce rounded-belt pattern adaptable to hip-type variation of women in their 20's. The results of this research were as follows : Firstly, based on drop-value distribution of hip and waist girth, 151 subjects were classified into three hip-types; Type 1 (15.23%) was 'cylinder type', showing lowest drop-value, Type 2 (69.54%) was 'average type' and Type3 (15.23%) was 'hourglass type' showing highest drop-value. Secondly, using CAD program, design lines for round shape belt were set on the surface of 3D scan data of representative subject of each type. And divided 3D surfaces were flattened onto the plane by the internal tools of CAD program. The measure, 'lifting value of round belt pattern', implying the level of curve ratio of pattern was higher in back than front. This result might be linked to the fact that the hip part is more protruded than the abdomen part. And the measures also showed highest values in Type 3(hourglass type) and lowest in Type 1(cylinder type), meaning that the pattern of Type 3 showed more rounded shape than that of Type 1. This finding implied that round belt for body type having high drop-value should be shaped more curved. Thirdly, difference ratios of outline length and area between 3D curves(body surface) and 2D plane(pattern) were 4.5% and 1.3%, respectively. This result demonstrated and solidified the feasibility of designing digital garment pattern from 3D body scan data.

3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로- (Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program -)

  • 홍은희
    • 한국의상디자인학회지
    • /
    • 제22권1호
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

3차원 인체 스캔 데이터를 활용한 남성용 바디스 원형 설계 방법 연구 (Men′s Bodice Pattern Making Method using 3-D Body Scan Data)

  • 서동애;천종숙
    • 복식문화연구
    • /
    • 제12권2호
    • /
    • pp.290-299
    • /
    • 2004
  • The purpose of this study is to testify the pattern making method to develop the men's basic bodice pattern using 3-dimensional body scan data. The experimental patterns were made by adding wearing ease on flattened body scan data and tracing the outlines of it. The experimental bodice pattern were composed of front, back, and side panels. To compare the difference between the experimental pattern and traditional pattern, two pattern making methods were compared. Two sets of basic bodice patterns were made for each of the 10 male subjects: a set of pattern was made by experimental method and the other set was made by Bunka pattern making method. The experimental and traditional patterns were measured at 13 dimensions. The results show that there was a difference between the experimental patterns and traditional patterns at the front length, back length, front width, front neck width, back neck width, and back neck depth. The fit was also compared for both patterns. The results of the fit test show that the experimental patterns were superior to the traditional patterns at the fit of neck, shoulder, and armhole. The experimental pattern making method was expected to be useful for mass customization.

  • PDF

3차원 인체형상 스캔데이터를 이용한 남자 바지패턴 설계 (Development of Men Slacks Pattern Using 3D Scan Data)

  • 손부현
    • 대한가정학회지
    • /
    • 제46권9호
    • /
    • pp.137-146
    • /
    • 2008
  • This study was conducted in order to spread out lower body 3D scan data of men in their twenties. The aim was to achieve slacks pattern with ease allowance through comparison with existing flat patterns. For conversion of 3D scan data into 20 pattern, reference lines were established by using Rapid Foam in 3D shape analysis software. 2C-AN program and Yuka CAD were used to convert 20 pattern earned with straight posture of 3D scan data into slacks pattern by using Triangle Simplification & Runge-Kutta Method. In order to achieve this we needed to set a line 9cm below the hip line, to array vertex of each block to crease line while maintaining the horizontal line. And then we needed to set ease allowance in back crotch and to set waist circumference or hip circumference ease allowance in side seam of slacks. Results showed that long front crotch length can be achieved if 3D scan data is compared with 20 existing flat pattern. Slacks pattern that raise front crotch by about 1.5cm compared to back crotch and also possess ease allowance in back crotch area are great in appearance evaluation.

3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석 (A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties)

  • 손부현;홍경희
    • 한국생활과학회지
    • /
    • 제18권3호
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF