• Title/Summary/Keyword: Body scan data

Search Result 218, Processing Time 0.03 seconds

A Study on Classification of Breast Shapes for Women in Their 30s (30대 여성 유방형태 분류에 관한 연구)

  • Kim, Hyo Sook;Kim, Ji Min
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.4
    • /
    • pp.106-117
    • /
    • 2014
  • The purpose of this study is to provide basic information for the development of well-fitting and comfortable brassieres for women in their 30s, based on the classification of breast shapes by utilizing 3D body measurement data of women in the age group. The result of processing the measurements from the 3D body scan data through RapidForm 2006 shows that while the vertical body measurements decrease, the horizontal measurements, which indicates the degree of obesity, increase proportionally with age. Also, the relevant measurements for upper breasts increase proportionally with age, while the measurements for lower part of the breasts decrease as the degree of sagging increases. Four composition factors of the breasts were identified through the factor analysis: Factor 1 is the level of volume in the breasts and the surrounding area; Factor 2 is the position of nipples and the shape of upper part of breasts; Factor 3 is the position and vertical length of the breasts; Factor 4 is the shape of lower part of breasts; and Factor 5 is the shape of inner part of breasts and degree of width between both breasts. The breasts have been categorized into three distinctive shapes: Breast Shape 1, Breast Shape 2 and Breast Shape 3. According to the results of the cluster analysis, the largest percentage (36.68%) of women in their 30s falls into the category of Breast Shape 2 with small volume and flat upper breasts, followed by Breast Shape 1 (32.66%) with large volume in the upper and lower parts of breasts, and large side to side area, and Breast Shape 3 (30.65%) with average volume and width between breasts.

Evaluation of kidney size in children: a pilot study of renal length as a surrogate of organ growth

  • Kim, Boo-Won;Song, Min-Kyoung;Chung, So-Chung;Kim, Kyo-Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.2
    • /
    • pp.54-57
    • /
    • 2012
  • Purpose: Somatic growth is an important indicator of health in children. Adequate organ growth is essential in growth and directly related to body growth. We consider renal length as a surrogate of organ growth in growing children. Measurement of weight, height, and many anthropometric indices, such as body surface area (BSA), body mass index (BMI), and Rohrer and Kaup indices, are used to evaluate growth status. The aim of this study was to evaluate the association between renal length and somatic parameters and analyze the affecting factors for renal size during growth. Methods: The data for renal length in 66 children (age, $12.9{\pm}15.6$ months; male/female, 34/32) were obtained. Each kidney was measured with ultrasonography and dimercaptosuccinic acid scan. The data on age, sex, height, and weight were obtained from the medical records. BSA, BMI, and Rohrer and Kaup indices were calculated from measured height and weight. BSA was calculated by 2 methods, and is expressed as BSA I and BSA II. Results: There were significant correlations between renal size and age, weight, height, BSA I, BSA II, and Rohrer index. In the regression analysis, the most significant contributing factor to renal growth was height ($R^2$=0.636, $P$ <0.001). Conclusion: Height seems to be the most important factor associated with organ growth in growing children. Further studies to evaluate adequate organ growth should be carried out.

3D Image Analysis for Digital Restoration and Structural Stability Evaluation of Stone Cultural Heritage: Five-storied Magoksa Temple Stone Pagoda (석조문화재 디지털복원 및 구조안정성 평가를 위한 3차원 영상분석: 마곡사오층석탑)

  • Jo, Young-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.2
    • /
    • pp.115-130
    • /
    • 2009
  • This study was focused on digital restoration and structural stability evaluation applying 3D scanning system of five-storied Magoksa temple stone pagoda in Gongju. For these, the digital restoration of the pagoda was completed using laser scan data which is measured 16 directions and data processing program of 7 stages. As a result of digital restoration, the overall height and width of stone properties showed a little difference in directions and the width of roof stones appeared very high difference of each floor. The width of pagoda body become smaller to the fifth floor, but gradual decrease rate showed irregular characteristics. Also, as result of 3D image analysis for structural stability evaluation, the displacement occurred toward northwest in second body stone to upper final stone except for central axis of the first body stone which inclines toward southwest. Such 3D image analysis is required quantification of survey method and should be applied to various field such as quantitative damage maps in order to utilize a conservation of stone cultural heritages, continuously.

  • PDF

Hip Protector Design Process for the Korean Elderly

  • Jeon, Eun-Jin;Kim, Hee-Eun
    • Fashion & Textile Research Journal
    • /
    • v.18 no.4
    • /
    • pp.520-530
    • /
    • 2016
  • This research aims to propose an ergonomic design process for hip protector based on previous studies, existing products, multidisciplinary experts opinion, and wearing test. The elderly are more likely to suffer a hip fracture when they fall due to their physical changes in skeletal form, muscle quantity, bone density, and joint movement. A hip protector is an effective product to prevent hip fractures in the elderly but it also has a problem in that it is uncomfortable. Therefore there is a high chance that it won't be able to prevent hip fractures properly. Since the comfort of a hip protector is one of the most critical elements in preventing a hip fracture, we need to keep improving the hip protector for mobility and usability. Based on the previous studies and limitations of current hip protector products, we need to come up with an optimal design for the Korean elderly. First, knowledge has to be built relating to the ergonomic design of the hip protector considering body shape and size analysis using 3D-scan data, and biomechanical analysis on hip fracture. Second, we need to develop a design process including hip protector pattern design, and wearing evaluation with virtual system. Third, we suggest to reevaluate and verify the design procedure from impact evaluation using testing simulator, virtual evaluation of impact, to wearing comfort and usability evaluation. This design process presented in this study would be expected to contribute to the development of ergonomic hip protector which is suitable for the Korean elderly.

Biomechanical Analysis of the Artificial Discs (인공디스크에 대한 생체역학적 분석)

  • Kim Young-Eun;Yun Sang-Seok;Jung Sang-Ki
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.907-910
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain, biomechanical change with its implantation was rarely studied. To evaluate the effect of artificial disc implantation on the biomechanics of functional spinal unit, nonlinear three-dimensional finite element model of L4-L5 was developed with 1-mm CT scan data. Two models implanted with artificial discs, SB $Charit\acute{e}$ or Prodisc, via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments and facet joint, and the stress distribution of vertebral endplate for flexion-extension, lateral bending, and axial rotation with a compressive preload of 400 N were compared. The implanted model showed increased flexion-extension range of motion and increased force in the vertically oriented ligaments, such as ligamentum flavum, supraspinous ligament and interspinous ligament. The increase of facet contact force on extension were greater in implanted models. The incresed stress distribution on vertebral endplate for implanted cases indicated that additinal bone growth around vertebral body and this is matched well with clinical observation. With axial rotation moment, relatively less axial rotation were observed in SB $Charit\acute{e}$ model than in ProDisc model.

  • PDF

A Study on the Development of the Automatic Drafting of Slacks Pattern for Elementary School Girls and the Evaluation of Fitness of Slacks Using 3D Scanner (3D Scanner를 활용한 학령후기 여아의 바지 원형자동제도 프로그램 개발 및 착의평가에 관한 연구)

  • Suk, Eun-Young;Kim, Hae-Kyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.59-79
    • /
    • 2002
  • The purposes of the study were to present the optimum slacks pattern for elementary school girls and to compare and evaluate wearing ease of the slacks. 3D scans using the Cyberware PS motion platform were carried out for 3 subjects who have different body type. The automatic drafting method was programmed by AutoLISP in CAD. Wearing tests using 3D Scanner was done for evaluation of fitness of slacks. Regression analysis, analysis of variance and post-hoc test were performed for statistical analysis of the data by SPSS program. The procedure and results were as follows: The slacks construction components for pattern drafting were derived from 10 horizontal section maps obtained from 3D scans. The automatic drafting was based on the measurements of slacks construction components and the curve of crotch line. The crotch line was drafted using of the arc function in AutoCAD. The total crotch length was calculated using the multiple regression equation. Wearing test represented that the slacks pattern developed to accomodate individual body measurements was estimated more highly than existing patterns.

The Effect of Pelvic Tilt Exercise with Changing the Body Position on Foot Contact Pattern in Hemiplegic Patients (자세에 따른 골반경사운동이 편마비 환자의 발 접촉양상에 미치는 효과)

  • Jang, Sang-Hun;Park, Soo-Jin;Kim, Min-Hee;Kim, Joong-Hwi;Kim, Jin-Sang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.3
    • /
    • pp.445-453
    • /
    • 2010
  • Purpose : The purpose of this study was to investigate the effect of pelvic tilt exercise with changing the body position on foot contact pattern in the hemiplegic patients. Methods : Thirty seven hemiplegic patients were randomly divided 3 groups; control group (CG), sitting exercise group (SIEG) and standing exercise group (STEG). F-mat system and F-scan system were used for the measurement of foot contact pattern of hemiplegic side in walking. Data were analyzed statistically using paired t-test and one-way ANOVA. Results : The results were as follows : 1) Contact area of CG and SIEG were not significant difference in walking. Contact area of STEG was significant increased in walking. 2) Anteroposterior distance of COP of SIEG and STEG were significant increased in walking. Conclusion : These results suggest that pelvic tilt exercise in sitting and standing position are effective in the improvement of Anteroposterior distance of COP and gait stability are increased in only standing position.

Analysis of biomechanical change of adjacent motion segment of the lumbar spine with an implanted artificial disc (인공추간판 적용 시 인접 운동 분절에서의 변화 분석)

  • Kim Y.E.;Yun S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.244-247
    • /
    • 2005
  • Although several artificial disc designs have been developed for the treatment of discogenic low back pain and used clinically, biomechanical change with its implantation seldom studied. To evaluate the effect of artificial disc implantation on the biomechanics of lumbar spinal unit, nonlinear three-dimensional finite element model of L1-L5, S1 was developed and strain and stress of vertebral body and surrounding spinal ligaments were predicted. Intact osteoligamentous L1-L5, S1 model was created with 1-mm CT scan of a volunteer and known material property of each element were applied. This model also includes the effect of local muscles which was modeled with pre-strained spring elements. The intact model was validated with reported biomechanical data. Two models implanted with artificial discs, SB Charite or Prodisc, at L4/5 via anterior approach were also developed. The implanted model predictions were compared with that of intact model. Angular motion of vertebral body, force on spinal ligaments, facet joint contact force with $2\sim12$ Nm flexion-extension moment.

  • PDF

PROTOTYPE ALGORITHM OF RADIOMETRIC CALIBRATION FOR IR CHANNELS ON GOES-12

  • Chang Ki-Ho;Oh Tae-Hyung;Ahn Myung-Hwan
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.691-693
    • /
    • 2005
  • The prototype of the radiometric calibration algorithm, including the correction of scan mirror's angle, has been developed for the stationary meteorological sensor, firstly in Korea. We use this system on GOES-12 to evaluate two coefficients, slope and intercept. The evaluated coefficients show good agreement with the NESDIS's results for the five-case data. The calculated coefficients have been applied to the conversion from the measured counts to the radiance and the converting methods according to the scanning are investigated to enhance the radiometric accuracy.

  • PDF

Classification and Characteristics of Neck-base Shape of Korean Females in Their Twenties (20대 여성의 목밑둘레 형태 유형화 및 특징)

  • Hwang Keun Young;Nam Yun Ja;Park Jae Kyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.3_4 s.141
    • /
    • pp.502-510
    • /
    • 2005
  • The purpose of this study is to identify neck shapes of women by classifying their neck-base types according to the shapes of neck and analyzing the characteristics of each type. The subjects were 58 women $18\~24$ years of age. Their body were measured directly and indirectly by using camera, 3-dimensional body scanner. The anthropometric measurements were composed of 17 items. They were measured during the months of October in 2001 The results and discussions of this study are as follows. There were three kinds of neck-base type. The first type was slant from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. The second type was gentle from the back neck-base to the side neck-base, and gentle from the side nect-base to the front neck-base. finally, the third type was gentle from the back neck-base to the side neck-base, and slant from the side neck-base to the front neck-base. Hopefully, understanding the shapes of neck and characteristics of each neck-base type will help to suggest computer assisted neck-base's landmark identification algorithms and measurement extraction methods from three-dimensional body scan data.