• 제목/요약/키워드: Body leakage

검색결과 211건 처리시간 0.024초

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구 (A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility)

  • 김두현;강동규
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

차체 기밀특성이 선루프 성능에 미치는 영향 연구 (Study of Effects of Body Leakage on Performance of a Sunroof)

  • 이영림
    • 한국자동차공학회논문집
    • /
    • 제9권3호
    • /
    • pp.201-209
    • /
    • 2001
  • Some passenger cars with sunroofs open at tilted positions experience reverse flows into cabin rooms and wind noises much louder compared to other cars. In this study, flows around open sunroofs are numerically studied with the variations of body leakage. The effects of body leakage on ventilation and wind noise of a sun roof are examined, in particular. Furthermore, flow visualization, pressure, and noise measured from wind tunnel and road tests are presented. The results show that too small body leakage results in poor performance of ventilation and generates high wind noise around a sunroof. It is therefore very important to secure an adequate body leakage from the early design stage to achieve better performance of a sunroof as well as passengers' comfort related to HVAC(Heating, Ventilation, and Airconditioning).

  • PDF

누설전류로 인한 전기화재 및 감전사고 예방기법 (Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current)

  • 김동우;임용배;이상익;김재현;강대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.

Introduction to Industrial Applications of Low Power Design Methodologies

  • Kim, Hyung-Ock;Lee, Bong-Hyun;Choi, Jung-Yon;Won, Hyo-Sig;Choi, Kyu-Myung;Kim, Hyun-Woo;Lee, Seung-Chul;Hwang, Seung-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권4호
    • /
    • pp.240-248
    • /
    • 2009
  • Moore's law has driven silicon technology scale down aggressively, and it results in significant increase of leakage current on nano-meter scale CMOS. Especially, in mobile devices, leakage current has been one of designers' main concerns, and thus many studies have introduced low power methodologies. However, there are few studies to minimize implementation cost in the mixed use of the methodologies to the best of our knowledge. In this paper, we introduce industrial applications of low power design methodologies for the decrease of leakage current. We focus on the design cost reduction of power gating and reverse body bias when used together. Also, we present voltage scale as an alternative to reverse body bias. To sustain gate leakage current, we discuss the adoption of high-$\kappa$ metal gate, which cuts gate leakage current by a factor of 10 in 32 nm CMOS technology. A 45 nm mobile SoC is shown as the case study of the mixed use of low power methodologies.

위암의 정규 위절제술 후 발생한 문합부 누출의 치료 결과 (The Result of Treatment of Anastomotic Leakage after an Elective Gastrectomy for an Adenocarcinoma)

  • 심요섭;김찬영;양두현
    • Journal of Gastric Cancer
    • /
    • 제4권3호
    • /
    • pp.164-168
    • /
    • 2004
  • Purpose: The most feared complication of gastrointestinal tract operations is anastomotic leakage, not only because of the presumed individual surgeon's culpability but also because of the assumption that this event is often fatal. We have experienced 32 cases of anastomotic leakage after elective gastric resection during 8 years. The purpose of this study was to evaluate the result of their treatment. Materials and Methods: We evaluated the records of 1335 patients who had undergone elective gastric resection for an adenocarcinoma of stomach from January 1995 to October 2003 and conducted a retrospective, multivariate analysis. Results: Of the 1335 patients, 32 ($2.4\%$) sustained an anastomotic leakage. Anastomotic leakages usually developed on mean postoperative day $9.1\pm3.2$ (range:$1\∼18$ days).Overall, $31.3\%$ (10/32) of patients who sustained an anastomotic leakage died. The anastomotic leakages were identifed by radiological study or by operative finding at the site of the duodenal stump (20 patients), the esophagojejunostomy (7), the gastroduodenostomy (4), and the gastrojejunostomy (1). Fourteen patients ($43.8\%$) underwent a relaparotomy, a drainage procedure in the main, and 18 patients ($56.3\%$) were treated conservatively. The mortality rates were $42.9\%$ (6/14) and $22.2\%$ (4/18), respectively, but this difference was not statistically significant. A cox's proportional hazard analysis showed that a body-mass Index < 24 kg/m2 (odds ratio 5.55, $95\%$ CI: $0.69\∼44.82$) and non-enteral feeding (odds ratio 18.27, $95\%$ CI 2.22.150.69) were independent factors of mortality due to anastomotic leakage. Conclusion: Our observations show that anastomotic leakage after an elective gastric resection has a high risk of being fatal. Moreover, for a patient with a body-mass index lower than $24\;kg/m^{2}$ and/or non-enteral feeding, an anastomotic leakage after an elective gastric resection has a higher risk of being fatal.

  • PDF

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

키보드 누설 방사에 의한 정보 누설 취약성 분석 (Analysis on the Vulnerability of Information Leakage through Electromagnetic Emanations from PC Keyboard)

  • 이대헌;황인호
    • 한국전자파학회논문지
    • /
    • 제18권1호
    • /
    • pp.76-81
    • /
    • 2007
  • 본 논문에서는 PC 키보드의 누설 전자파에 의한 정보 누설 취약성을 분석하였다. 먼저 키보드 프로토콜과 하드웨어 구조를 살펴보고, 키보드에서 PC 본체로 전송되는 데이터 신호와 본체 전원선에 누설된 신호 사이의 상호 관계를 분석함으로써 키보드 전도성 방사의 원인을 파악하였다. 또한 키보드 누설 전자파의 크기를 계산하고 CTSPR 22 규격의 허용 레벨과 비교하였다. 간단한 실험을 통하여 PC본체 전원선의 신호를 분석하여 키보드 글쇠 내용을 얻을 수 있음을 보임으로써, PC 사용자의 중요 정보가 누설될 수 있음을 확인하였다.

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Ultrathin-body MOSFET의 leakage current와 관련한 SiGe alloy substrate의 특성 평가

  • 이동헌;강영호
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제3회(2014년)
    • /
    • pp.415-419
    • /
    • 2014
  • 나노스케일 MOSFET에서 leakage current는 중요한 이슈로서 $Si_{1-x}Ge_x$ alloy를 substrate로 사용할 경우 leakage current에 어떤 영향을 미칠 것인지 시뮬레이션을 통하여 알아보았다. $Si_{1-x}Ge_x$ alloy에서 Ge의 비율이 증가할수록 유효질량이 작아졌으나 conduction band minimum의 위치는 Si에 비해 상승하였다. 이로 인해 tunneling 확률이 증가하여 $Si_{1-x}Ge_x$ alloy를 substrate로 사용할 경우 leakage current를 더욱 증가시키게 되었다.

  • PDF