• Title/Summary/Keyword: Body contouring

Search Result 32, Processing Time 0.029 seconds

Nontuberculous Mycobacterial Infection after Body Contouring Procedure, Case Report (체형 교정 시술 후 발생한 비정형 마이코박테리아 감염, 증례 보고)

  • Jeong, Jae-Yeon;Lim, So-Young;Pyon, Jai-Kyong;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.293-296
    • /
    • 2010
  • Purpose: NTM (non tuberculous mycobacteria) is rare cause of surgical site infection after plastic surgery in immunocompetent patients. There are some reports about NTM infection after body contouring procedure from Latin America. But, there is no report in Korea. The purpose of this article is to report 2 patients with soft tissue infection caused by NTM after body contouring procedure. Methods: Two young female patients exhibited signs of inflammation and abscess after body contouring procedure. One patient underwent liposuction. The other underwent HPL (hypotonic pharmacologic lipo-dissolution) injection. Results: The result of tissue cultures were positive for NTM. All patients responded to the combined therapeutic approach. Conclusion: The goal of this article is to raise awareness among plastic surgeons who may encounter such patients in their practice. NTM should be included in the differential diagnosis of surgical site infection after body contouring surgery.

The Comparison of Image Quality Using Body Contour and Circular Method with L-mode in Myocardial Perfusion SPECT (Tl-201을 이용한 심근관류 SPECT에서 Body contour와 Circular mode의 영상 획득 차이에 따른 영상의 질 비교)

  • Kim, Sung-Hwan;Nam, Ki-Pyo;Ryu, Jae-Kwang;Yoon, Soon-Sang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.3-7
    • /
    • 2012
  • Purpose : In myocardial perfusion SPECT, the type of orbit (circular vs. body contouring) that affect the image quality is still on the debate. Presently in the nuclear medicine field, the body contouring orbit acquisition is widely used to improve the image quality on the myocardial perfusion SPECT. But in case of body contouring acquisition using the vertical method with dual detect machine, there is a tendency of increasing the radius. In this research, we compared body contouring orbit acquisition with circular orbit acquisition, so we suggest ideal method that reduces the radius for improving image quality. Materials and Methods : Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on equally with counts from patient's body. The study was performed under six different conditions. To compare image quality according to the radius, we increased radius sequentially per step during circular orbit acquisition. On the other hand, sensors that protect a collision and reduce the radius automatically were used to acquire image during body contouring orbit acquisition. So we compared FWHM value of apex. In clinical studies, we analyzed the 40 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center in August 2011. To acknowledge the differences according to the radius, we acquired the results two times using circular orbit acquisition and body contouring orbit acquisition. Results : In phantom study, we analyzed that increase of radius resulted in changes of FWHM value. It was 5.41, 6.24, 6.33, 6.42, 6.93 mm. On the other hand, using the body contouring orbit acquisition, FWHM value was 6.23 mm. In clinical study, difference of average radius between two methods was 2.5 cm (circular orbit acquisition was more close to patients). Conclusion : Through the experiments using Anthropomorphic torso phantom and patients data, we found that FWHM value of circular orbit acquisition was lower than body contouring orbit acquisition. As a result, if the difference of average radius exists approximately 3 cm, circular orbit type acquisition is better than body contouring type acquisition. But clinical investigation is only aimed to average radius, so it needs more investigation in comparison of patient's image.

  • PDF

Contouring of Forehead and Temple Area with Auto-Fat Injection (지방주입술을 이용한 전두 및 측두 부위의 윤곽교정술)

  • Kang, Jae-Hoon;Jung, Seung-Won;Lee, Yong-Hae;Kook, Kwang-Sik
    • Archives of Plastic Surgery
    • /
    • v.38 no.2
    • /
    • pp.166-172
    • /
    • 2011
  • Purpose: Facial contouring surgery for improving congenital, acquired deformity and senile change were attempt in past. Recently contouring surgery became more interested subject for improving the flat forehead and temple area. Many synthetic materials were used such as Collagen, silicon, polyacrylamide gel as liquid form and Gore-tex, silicon implant, endotine as solid form. But, these synthetic implants associate complications as foreign body reaction, infection, displacement, granuloma formation and absorption. Auto-fat injection are used for disfigurement of many part of body. We did auto-fat injection for facial contouring of forehead and temple region. Auto-fat injection is suitable without foreign body reaction, displacement, and toxic reaction. Also auto-fat is relatively simple to obtain from patient and less expensive and able to repeat surgeries. Methods: From 2006 to 2009, 150 patients were treated with Auto-fat injection for facial contouring. For follow up, we sent questionnaire to all patients but 110 patients returned answer sheets. The patients consisted of 20 male patients and 90 female patients with an age ranged from 26 to 60, and the mean 43. Fat tissue were injected 6-8 cc in forehead, 7-12 cc in temple area and fat were harvested from thigh and abdomen. Results: In follow up, all patients, showed absorption of injected fat varied degree and except two patients all patients underwent secondary fat injection. Complications were minimal and neuropraxia of facial nerve were recovered. Most of the patients were satisfied with result of procedure, and answered that they recommend same procedure to their friends and will do surgery again. Conclusion: Auto-fat injections were implemented for facial contouring in 150 patients and obtained satisfactory result. Auto-fat injection is relatively easy procedure and applicable widely. Even though, by passing time, some of the injected fats are absorbed, auto-fat injection could be choice of treatment for contouring forehead and temple. With accumulations of cases and development of surgical technique, better result could be expected.

Slimming of Lower Face by Contouring of the Mandibular Body in Orthognathic Surgery Patients

  • Park, Bong-Wook;Kang, Young-Hoon;Choi, Mun-Jeoung;Kim, Si-Yeob;Kang, Hea-Gea;Kim, Jong-Ryoul;Byun, June-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.5
    • /
    • pp.325-330
    • /
    • 2013
  • The patient's appearance can be dramatically enhanced as a result of orthognathic surgery. However, esthetic contouring of the mandibular body portion is often overlooked in the surgery. Restoring a more beautiful jaw line is important and directly affects surgical results. From December 2010 to February 2012, we performed mandibular body contouring for the slimming of the third lower part of the face in 37 patients who had undergone either 1-jaw surgery or 2-jaw surgery. The third lower part of the facial contour was improved in all the patients after at least 3 months follow-up. Mandibular body contouring is a simple method that can be additionally used for the slimming of the third lower part of the face in patients who require orthognathic surgeries. It makes the lower face look more attractive from both the anterior and lateral perspectives.

Upper Arm Contouring with Brachioplasty after Massive Weight Loss

  • Han, Hyun Ho;Lee, Min Cheol;Kim, Sang Hwa;Lee, Jung Ho;Ahn, Sang Tae;Rhie, Jong Won
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.271-276
    • /
    • 2014
  • Background As the obese population increases in Korea, the number of patients who are trying to lose weight has been increasing steadily. In these patients, skin laxity and deformation of the body contour occurs, which could possibly be corrected by various body contouring surgeries. Here, we introduce the brachioplasty method and our experience of various body contouring surgeries performed in our center. Methods From November 2009 to August 2011, five cases of brachioplasty were performed. When the patient presented with sagging of the lateral inframammary crease and bat wing deformity in the axilla, extended brachioplasty was performed; in this case, the deformation of the axilla and lateral chest was corrected at the same time. A traditional brachioplasty was performed when contouring was needed only for skin laxity in the upper arm. Results Complications, such as hematomas or nerve injuries, were not evident. Some patients experienced partial wound dehiscence due to tension or hypertrophic scars found during the follow-up. In general, all of the patients were satisfied with the improvement in their upper arm contour. Conclusions Given the demands for body contouring surgery, the number of brachioplasty surgical procedures is expected to increase significantly, with abdominoplasty comprising a large portion of these surgeries. For the brachioplasty procedure, preparation and preoperative consultation regarding design of the surgery by experienced surgeons was important to prevent complications such as nerve damage or hematoma formation.

Reducing pain and opioid consumption after body contouring of the breast by application of a perioperative nerve block: a systematic review

  • Asserson, Derek B.;Sahar, David E.
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.361-365
    • /
    • 2021
  • Background Pain in the postoperative body contouring patient has traditionally been managed with narcotic medication. In an effort to minimize side effects and prevent addiction, plastic surgeons are searching for novel ways to provide adequate analgesia, one of which is nerve blocks. This study was conducted with a meta-analysis that evaluates the efficacy of these blocks for patients who undergo breast surgery. Methods A search of the PubMed/MEDLINE database for articles including the terms "post-operative analgesia" OR "postoperative pain management" AND "in plastic surgery" OR "in cosmetic surgery" OR "in elective surgery" in February 2019 generated five studies on elective breast augmentation and reduction mammoplasty that reported pain scores and quantities of opioids consumed. Independent samples t-tests, one-way analysis of variance, and a random effects model were implemented for evaluation. Results A total of 317 patients were identified as having undergone body contouring of the breast, about half of which received a nerve block. Pain scores on a 1-10 scale and opioid dose-equivalents were calculated. Those who were blocked had an average score of 2.40 compared to 3.64 for those who did not (P<0.001), and required an average of 5.20 less narcotic doses (P<0.001). Pain relief following subpectoral augmentation was best achieved with type-II blocks as opposed to type-I and type-II with serratus plane (P<0.001). Conclusions The opioid epidemic has extended to all surgical specialties. Implementation of a nerve block seems to be an efficacious and cost-effective mechanism to not only help with post-operative pain, but also lower the need for narcotics, especially in subpectoral augmentation.

Two Cases of Lower Body Contouring with a Spiral and Vertical Medial Thigh Lift

  • Kim, Sang-Wha;Han, Hyun-Ho;Seo, Je-Won;Lee, Jung-Ho;Oh, Deuk-Young;Ahn, Sang-Tae;Rhie, Jong-Won
    • Archives of Plastic Surgery
    • /
    • v.39 no.1
    • /
    • pp.67-70
    • /
    • 2012
  • Massive weight loss results in skin excess, leading to an unsatisfying body contour. Various thigh lift procedures can correct flabby skin in the lower leg. We present a lower body contouring technique with a report on two patients. The procedure is determined by the body contour of the patient. As the skin excess in the thigh area tended to appear mostly on the medial side, a vertical medial thigh lift was considered. Moreover, for patients with a pear/guitar-shaped body contour, we added the spiral thigh lift for skin excess in the buttocks and the lateral thigh area. The extent of tissue to excise was determined by pinching the patient in a standing position. The inferior skin flap was fixed to non-movable tissue, which was helpful for lifting the tissue and preventing the widening of the scar. After the operation, a drain was kept for 3 to 4 days. A compressive garment was used after removing the drain. There were no complications. The patients were discharged 6 to 8 days after the operation. In conclusion, skin excess, especially in the lower body, can be corrected by a thigh lift combining several procedures, varying from person to person.

MANDIBULAR CONTOURING SURGERY BY MULTIPLE STEP SURGICAL CORRECTION WITH ANGLE-SPLITTING OSTECTOMY (하악 외측피질골 절제술을 동반한 다단계 하악 우각부 윤곽성형술)

  • Lee, Han-Joo;Park, Hyun-Wook;Koh, Kwang-Soo;Huh, Won-Shil
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.204-210
    • /
    • 2000
  • The mandibular contour determines the shape of the lower part of the face and thus influences the appearance of the face. A patient with a large, squarish, or broad face who desires a small, round, or slender face can undergo mandibular contouring surgery to reduce the width of the lower face. The successful correction of a prominent mandibular angle by conventional angle ostectomy has been reported. But, in the majority of patients with a widened facial appearance, both the mandibular angle and part of the mandibular body anterior to it are protuberant laterally, so both must be resected. The purpose of this study is to introduce a new method of performing mandibular contouring surgery, more effectively and easily, and to reduce postoperative complication and evaluate its results. We treated 6 patients who has prominent mandibular angle using multiple step osteotomy with angle-splitting ostectomy. The advantages of this new method are as following. (1) easily performable (2) effective mandibular contouring surgery by reducing the width of lower face (3) producing a natural relief of the mandibular angle (4) low risk of soft tissue damage and complications (5) shortening of the operation time. etc.

  • PDF

Clinical application of cryolipolysis in Asian patients for subcutaneous fat reduction and body contouring

  • Oh, Chang Hyun;Shim, Jeong Su;Bae, Kwang Il;Chang, Jae Hoon
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • Background Cryolipolysis, a preferred method for minimally invasive body contouring, involves the noninvasive cooling of adipocytes to induce lipolysis without damaging other tissues. This study aimed to evaluate the safety and efficacy of cryolipolysis for the treatment of excessive fat tissue. Methods Between May 2014 and December 2017, 231 patients with 448 areas of interest were enrolled and their records were retrospectively reviewed. We used five different vacuum applicators, and the best-fitting applicator was used for each area. One cycle of cryolipolysis was applied at a cooling intensity factor of 41.6. The efficacy was evaluated 12 weeks after treatment via review of clinical photographs, the pinch test, and ultrasonographic measurements of fat thickness. The occurrence of any complications was also assessed. Results The volume was reduced in all of the areas to which cryolipolysis was applied. The rate of reduction of the fat layer as measured via the pinch test was 19.2%, and the rate of the decrease in fat layer thickness as measured via ultrasonography was 22.8%. Fat reduction of the upper arm differed significantly from that of the abdomen and flank, but no significant difference was found between sexes. The side effects were limited to erythema, edema, bruising, and numbness at the treatment site and resolved without treatment. Conclusions Cryolipolysis, with new and better-fitting applicators, is safe, fast, and effective for the reduction of excessive fat tissue on the abdomen, back, flank, and extremities. It is a good option for treating excess adipose tissue in Asian patients.