• 제목/요약/키워드: Body Resonance

검색결과 522건 처리시간 0.029초

Resonance Phenomenon and Its Effects of Laser Texture Disk

  • Choa, Sung-Hoon;Wang, Geng
    • Journal of Mechanical Science and Technology
    • /
    • 제14권7호
    • /
    • pp.744-751
    • /
    • 2000
  • To achieve lower flying height for high areal recording density, the laser zone texturing of the disk needs to be designed to reduce glide height. One problem of the laser bump design is that the regular laser bump pattern often produces glide resonance phenomenon, which leads to failure of the glide height test. However, it was found in this study that glide resonance is an intrinsic problem of the glide head used and resonance phenomenon depends on the type of the head slider, that is, the natural frequency of the slider body. Therefore, higher glide height or glide failure caused by glide resonance does not lead to head/media interface problem in the real drive operating conditions in which the data head is used. Pseudo-random bump pattern greatly reduces the glide resonance. Smaller bump pitch will also help to reduce the glide resonance. However, as bump spacing becomes smaller, glide height will be increased due to increased air pressure developed around the bumps. Lowering bump height is the most effect way to reduce glide avalanche.

  • PDF

자수된 직물 다이폴안테나에 미치는 인체영향에 대한 분석 (An Investigation of human body influence on Embroidered Textile Dipole Antenna)

  • 기현철
    • 한국인터넷방송통신학회논문지
    • /
    • 제21권5호
    • /
    • pp.155-160
    • /
    • 2021
  • 본 논문에서는 자수된 직물 다이폴 안테나의 웨어러블 안테나로서의 적합성을 분석하였다. 폴리에스터 직물 위에 자수로 2.45GHz ISM 밴드 다이폴 안테나를 설계하였다. 직물의 두께(ttextile), 직물과 신체 표면과의 거리(gbody) 및 신체 표면의 전도도(𝜎body)의 3가지 변수에 따른 그 안테나의 특성을 분석하였다. 직물의 두께(ttextile)는 안테나 공진 주파수(fo)에 영향을 주고 있었다. 신체 표면 전도도(𝜎body) 증가에 따른 안테나 공진주파수(fo)와 안테나 이득은 미세하게 증가하는 특성을 보였다. 직물과 신체표면과의 거리(gbody) 증가는 안테나 공진주파수(fo)와 안테나 이득의 상대적으로 큰 폭의 증가를 야기했다. 위의 결과로 볼 때 웨어러블 안테나로서 자수된 직물 다이폴 안테나를 설계할 경우 직물과 신체표면과의 거리(gbody)와 직물의 두께(ttextile)의 두 변수를 조심스럽게 고려하여야 할 것이다. 직물과 신체표면과의 거리(gbody)는 큰 폭의 변화를 하므로 자수된 다이폴 안테나를 설계하는 데 있어 기술적 장벽이 될 수 있을 것이다.

유니몰프 PZT 액츄에이터를 이용한 정밀 이송기구의 개발 (Development of Precision Moving Instrument by Using the Uni-morph type PZT Actuator)

  • 권현규;최성대
    • 한국기계가공학회지
    • /
    • 제7권1호
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents a new precision moving instrument for the displacement and direction control using the uni-morph type PZT actuator. The instrument is composed of the two-body and a link. The body has the uni-morph type PZT actuator, which make the vibration. Movement of simple moving instrument is generally analyzed by the theory of center-of-gravity moment. However the analysis of the instrument in this paper is focused the resonance of instrument. Resonance of the body is originated a uni-morph type PZT actuator that is vibrated by voltage and frequency. The basic performances of one body instrument are analyzed by the FEM analysis. And experiments are also performed to confirm the linear movement of the instrument and direction control. it is proper a voltage control than a frequency control for the direction changing. And Moving velocity is 0.032m/s.

  • PDF

단층형 압전진동자의 설계 및 제작 (Design and fabrication of unimorph type piezoelectric vibrator)

  • 전호익;김정환;지승훈;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1317-1318
    • /
    • 2007
  • On this paper, unimorph type piezoelectric vibrator made by attaching ceramic plates on rectangular elastic body, to find the basic characteristic of the actuators. In experiment, elastic body's displacement and resonance frequency were measured according to changes of ceramic's length and elastic body's length. Also, temperature changes were observed according to time. The displacement and resonance frequency were increased when the ceramic's length were increased. When elastic body's length was increased, the displacement was increased. Also, the temperature was increased according to time, but at some time it was saturated and the temperature was not increased any more.

  • PDF

음향 매질의 추가질량 효과를 고려한 광음향 영상용 초소형 압전 기반 초음파 트랜스듀서의 개발 (Development of a Piezoelectric Micro-machined Ultrasonic Transducer for Photoacoustic Imaging that Accounts for the Added Mass Effect of the Acoustic Medium)

  • 안홍민;문원규
    • 센서학회지
    • /
    • 제29권1호
    • /
    • pp.33-39
    • /
    • 2020
  • Typically, photoacoustic images are obtained in water or gelatin because the impedance of these mediums is similar to that of the human body. However, these acoustic mediums can have an additional mass effect that changes the resonance frequency of the transducer. The acoustic radiation impedance in air is negligible because it is very small compared to that of the transducer. However, the high acoustic impedance of mediums such as the human body and water is quite large compared to that of air, making it difficult to ignore. Specifically, in a case where the equivalent mass is very small, such as with a micro-machined ultrasound transducer, the additional mass effects of the acoustic medium should be considered for an accurate resonance frequency design. In this study, a piezoelectric micro-machined ultrasonic transducer (pMUT) was designed to have a resonance frequency of 10 MHz in the acoustic medium of water, which has similar impedance as the human body. At that time, the resonance frequency of the pMUT in air was calculated at 15.2 MHz. When measuring the center displacement of the manufactured pMUT using a laser vibrometer, the resonance frequencies were measured as 14.3-15.1 MHz, which is consistent with the finite element method (FEM) simulation results. Finally, photoacoustic images of human hair samples were successfully obtained using the fabricated pMUT.

예혼합 보염기 화염의 희박 화염 날림에 음향 가진이 미치는 영향에 관한 연구 (Analysis of Acoustic Excitation Effect on Lean Blowoff in Premixed Bluff Body Flames)

  • 정찬영;황정재;윤지수;김태성;신재익;윤영빈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.149-151
    • /
    • 2014
  • The blowoff phenomenon was experimentally investigated in a ducted combustor according to the acoustic excitation. The blowoff equivalence ratio rapidly increases at specific acoustic excitation frequencies. A resonance phenomenon occurs when the excitation frequency approaches the harmonic frequency of the combustor. The resonance increases the velocity fluctuation in the combustor and the infiltration velocity of the unburned gas in the shear layer. Consequently, the mixture velocity exceeds the burning velocity and the blowoff occurs at the higher equivalence ratio.

  • PDF

자성 유체를 이용한 1자유도 계의 공진멸소에 관한 실험적 연구 (An experimental study on resonance reduction of system with one degree of freedom by magneticfluid)

  • 전운학;이봉규;황승식;이희상;김중
    • 한국자동차공학회논문집
    • /
    • 제7권9호
    • /
    • pp.131-137
    • /
    • 1999
  • Under magnetism , as the magneticfluid is being itself magnetized, increase the apparent viscosity because of its body force and has the magnetic characteristics in response ot magnetism, the magnetic fluid is getting attention in various field. The magnetic fluid has the fluidity, which is a special characteristics of fluid and the magneticism , which is a special one of solid. Using this characteristics, this study has been proceeded to show the basic data for developing of a viscous damper with magnetism fluid as hydraulic fluid. Experimental study shows that the application of magnetic field is effective reducing the resonance characteristics of the spring-mass system.

  • PDF

박용 발전기세트 진동 제어를 위한 강성 조절형 마운트 개발 (Development of stiffness adjustable mount for vibration control of marine diesel generator set)

  • 김원현;주원호;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.89-92
    • /
    • 2012
  • Marine diesel generator(D/G) set which is supported with resilient mounts for vibration isolation has been experienced the resonance problem by the main engine or propeller excitations and rigid body modes. Then the avoidance of resonance is difficult because the several excitations and 6 rigid body modes have to be considered simultaneously. In this paper, stiffness adjustable mounts was developed and proposed to control the natural frequencies of installed D/G set. Operating concept of the mount is that the total stiffness of mount can be changed according to the engagement of secondary rubber element in addition to primary one. The performance of mount was verified with the test rig and actual experiment in D/G set.

  • PDF

동적 특성을 고려한 차량 현가 시스템의 내구해석 기법 (Durability Analysis Technique of Automotive Suspension System Considering Dynamic Characteristics)

  • 한우섭;이혁재;임홍재;이상범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.336-341
    • /
    • 2003
  • In this paper, resonance durability analysis technique is presented for the fatigue life assessment considering dynamic effect of a vehicle system. In the resonance durability analysis, the frequency response and the dynamic load on frequency domain are used. Multi-body dynamic analysis, finite element analysis, and fatigue life prediction method are applied for the virtual durability assessment. To obtain the frequency response and the dynamic load, the computer simulations running over typical pothole and Belgian road are carried out by utilizing vehicle dynamic model. The durability estimations on the rear suspension system of the passenger car are performed by using the presented technique and compared with the quasi-static durability analysis. The study shows that the fatigue life considering resonant frequency of vehicle system can be effectively estimated in early design stage.

  • PDF

Contralateral Internal Mammary Lymphadenopathy Mimicking Metastasis in a Patient with a History of Breast Cancer and Prior Interstitial Mammoplasty by Paraffin Injection: MRI, PET-CT, and Pathological Findings

  • Nam, Kyung Jin;Choo, Ki Seok;Kim, Jee Yeon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권4호
    • /
    • pp.245-248
    • /
    • 2018
  • Foreign body injections into breasts may produce foreign body reactions, fibrosis, and local swelling of involved lymph nodes, which can be misdiagnosed as metastasis or malignancy. Here, the authors report MR imaging, PET-CT imaging, and pathologic findings of contralateral internal mammary lymphadenopathy suspicious of breast cancer metastasis in a 58-year-old woman with history of left breast cancer, and previous interstitial mammoplasty by paraffin injection in both breasts.