• Title/Summary/Keyword: Body Resonance

Search Result 522, Processing Time 0.026 seconds

Magnetic Resonance Imaging Assessment of Paraspinal Muscles in Dogs with Intervertebral Disc Herniation

  • Ye-Jin Kim;Ju-Yeong Kim;Ah-Won Sung;Hyun-Ju Cho;I-Se O;Ho-Jung Choi;Young-Won Lee
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.334-341
    • /
    • 2022
  • A decrease in the paraspinal muscle cross-sectional area (CSA) and functional cross-sectional area (FCSA) are associated with low back pain and disc herniation in humans. This study examined whether chronicity or lateralization of disc herniation affects the CSA and FCSA of the paraspinal muscles. The CSA and FCSA of the paraspinal muscles between the 12th and 13th thoracic vertebrae were measured in 31 dogs with intervertebral disc herniation (IVDH). The muscle CSA and FCSA were evaluated by dividing the values of the body weight, spinal disc CSA, and spinal canal CSA to offset the differences in body type between subjects. In the chronic IVDH group, the ratio of the paraspinal muscle CSA divided by the body weight was significantly lower, and fat infiltration in the paraspinal muscle was significantly higher than in the acute group. The lateralization of the disc herniation was significantly related to the changes in the paraspinal muscle CSA. In the right-sided disc herniation group, right epaxial muscle CSA was significantly reduced compared to the left-sided disc herniation group. The change in the paraspinal muscle might be a helpful indicator to localize less obvious disc pathologies and target the search for the pathology responsible for disc-related symptoms in dogs.

Delayed Foreign Body Reaction around the Absorbable Implants in Facial Bone Fracture: A Case Report (안면부 골절에 사용된 흡수성 보형물의 지연성 이물반응: 증례보고)

  • Suh, Yong-Hoon;Kim, Young-Joon
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.875-878
    • /
    • 2011
  • Purpose: Absorbable implants are frequently used to fix facial bone fractures, because they are radiolucent and compatible with magnetic resonance imaging (MRI). Despite their increasing usage, however, there have been few reports about their long-term side-effects. In this paper, a case in which absorbable implants led to a foreign body reaction 17 months after their insertion is presented. Methods: A previously healthy 19-year-old male fell from a flight of stairs and visited the authors' hospital with right periorbital pain. Zygomaticomaxillary fracture involving right orbital floor was detected via a facial bone computed tomography (CT). Internal fixation with absorbable implants was followed by open reduction. 17 months after the surgery, the patient complained of localized periorbital swelling. Removal of the granulomatous lesion including the absorbable implants along with their biopsy and culture was performed. Results: The granulomatous lesion around the implants was firm and extended into the maxillary sinus. The histologic finding showed a microabscess with a foreign body reaction. Methicillin-sensitive Staphylococcus aureus growth was confirmed in the culture. No definite abnormal symptoms ensued after the complete removal. Conclusion: A microabscess-forming granulomatous lesion around the absorbable implant can cause delayed symptomatic foreign body reaction despite its rare occurrence. Complete removal of the lesion including implants is expected to have a successful outcome if it is encountered.

ANALYSIS ON THE VIBRO-ACOUSTICAL CHARACTERISTICS OF A PANEL-CAVITY COUPLED SYSTEM

  • Kim, Seock-Hyun;Kang, Sang-Wook;Lee, Jang-Moo
    • Journal of Theoretical and Applied Mechanics
    • /
    • v.3 no.1
    • /
    • pp.34-44
    • /
    • 2002
  • Theoretical analysis Is carried out to identify the modal coupling effect between some particular acoustic modes of a vehicle compartment cavity and vibration modes of body panels like side doors, roof or floor. A simplified panel-cavity coupled model is investigated on the coupled resonance frequencies, modes and frequency response characteristics. Through parametric study, It Is possible to explain how the acoustic response of a coupled system will be determined by the vibration and acoustic property of the individual panel and cavity system. Full coupled system shows some interesting features different from those of the semi-coupled system In frequency, mode and acoustic response.

  • PDF

급성 화폐상 습진을 동반한 아토피 피부염 환자의 한방치험 1례

  • Kim, Hye-Jeong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.14 no.1
    • /
    • pp.111-116
    • /
    • 2001
  • Nummular eczema is well-shaped, coin-like lesion. Usually it is surrounded by the papules and vesicles, and is likely to be the impetigo. It's said that nummular eczema is combined with atopic dermititis, contact dermatitis, bacterial infection and so on. Recently, we experienced a nummular eczema with impetigo and that was successfully treated by the herb-medication and the ceramic resonance therapy. The medications taken by the patient were yunwhasagnatang and gamisopungsan which is used to treat allergic disease and make immune system be strong. The former effects the liver to be cool down and healthy and it also has anti-imflamatory reactions like the corticosteroid hormone. Ceramic resonance therapy utilises irradiation within the frequency range of the radiation emitted by the human body. So we report this case with a brief review of the oriental medical and medical literatures.

  • PDF

Chronic Spinal Epidural Hematoma Related to Kummell's Disease

  • Kim, Heyun-Sung;Lee, Seok-Ki;Kim, Seok-Won;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.4
    • /
    • pp.231-233
    • /
    • 2011
  • Chronic spinal epidural hematoma related to Kummell's disease is extremely rare. An 82-year-old woman who had been managed conservatively for seven weeks with the diagnosis of a multi-level osteoporotic compression fracture was transferred to our institute. Lumbar spine magnetic resonance images revealed vertebral body collapse with the formation of a cavitary lesion at L1, and a chronic spinal epidural hematoma extending from L1 to L3. Because of intractable back pain, a percutaneous vertebroplasty was performed. The pain improved dramatically and follow-up magnetic resonance imaging obtained three days after the procedure showed a nearly complete resolution of the hematoma. Here, we present the rare case of a chronic spinal epidural hematoma associated with Kummell's disease and discuss the possible mechanism.

Dosimetry for Resonance-Based Wireless Power Transfer Charging of Electric Vehicles

  • Park, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • This paper presents the dosimetry of a resonance-based wireless power transfer (RBWPT) system for electric vehicles applications. The compact RBWPT system is designed to transfer power at 150-mm distance. The electric and magnetic fields generated by the RBWPT system and the specific absorption rate in the human body model, which stands around the system, are calculated. These analyses are conducted in two cases: the alignment and the misalignment between the transmitter and the receiver. The matching loops are adjusted to maximize the power transfer efficiency of the RBWPT system for the misalignment condition. When the two cases were compared for the best power transfer efficiency, the specific absorption rates (SAR) in the misalignment case were larger than those in the alignment case. The dosimetric results are discussed in relation to the international safety guidelines.

A Study on Vibration Reduction of Local Structure of Medium-speed Diesel Engine (중속 디젤엔진 국부 구조물의 진동저감 연구)

  • Jung, Kun-Hwa;Lee, Jun-Ho;Son, Jung-Ho;Ryoo, Young-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.257-261
    • /
    • 2011
  • The failures of local structure of marine medium-speed diesel engine occurred in durability test. The vibration response of the whole engine was in an acceptance level, but the local structures were broken. ODS test and vibration measurement were carried out in order to investigate the root cause of durability problem. These tests revealed that the root cause of failures was excessive vibration by $4.5^{th}$ resonance between engine body and local structure. The best solution to reduce the vibration response is to change the type of mount. After a rigid mount was replaced by a flexible mount, maximum vibration level dropped to 72%.

  • PDF

The Development of Chestpiece Detecting Techniques for Physical Assessment Trainer (청진 훈련 모형용 청음판 검출 알고리즘 개발)

  • Chang, In Bae;Oh, Soo Hwan;Lee, Young Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.6
    • /
    • pp.527-534
    • /
    • 2014
  • The control system of human torso model and driving system of stethoscope for physical assessment trainer are developed. The detecting characteristics of circular pickup coil which is driven by square wave voltage signal with resonance frequency of LC circuits are investigated and it is confirmed that the pickup coil can detect the existence of chestpiece near the coil region. The control system of human torso model is composed of 8 channel pickup coils, Mp3 and Bluetooth module. The driving system of stethoscope is composed of chestpiece with contact switch and Bluetooth headset. The chestpiece detecting algorithm check the contact of chestpiece with human body model first and excite the pickup coil sequentially to find the location. The proposed system can be applied the physical assessment trainer.

Shielded High-Order Gradient Coil Design for Magnetic Resonance Spectroscopy and Imaging (자기공명분석과 영상촬영을 위한 차폐된 고차경사자계코일의 설계)

  • Oh, Chang-Hyun;Hilal, Sadek K.;Yi, Yun;Kim, Min-Gi
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.45-48
    • /
    • 1993
  • High-order field gradients are useful for spatial localization of a volume of interest and dynamic range improvement of signal detection in NMR (Nuclear Magnetic Resonance) spectroscopy and imaging. This paper proposes a design method of shielded high-order gradient coils to reduce tile effect of eddy current on tile spectroscopy and imaging results. According to the experimental results, the shielded gradient coils produce less than 2 % eddy current compared to non-shielded coils. Two shielded $z^2$ gradient coils have been designed and constructed for 1.5 T whole-body and 3.0 T animal NMR imaging systems. Experimental results are in good agreement with the theoretically expected behavior and show the utility of the shielded high-order gradient coils.

  • PDF

The effects of Mozart's music on metabolic response upon stress

  • Lee, Sujin;Yoo, Ga Eul;Chong, Hyun Ju;Choi, Seung Hong;Park, Sunghyouk
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.24 no.1
    • /
    • pp.23-29
    • /
    • 2020
  • Mozart's music has been suggested to affect spatio-temporal reasoning of listeners, which has been called "Mozart effect". However, the effects of Mazart's music on human metabolism have not been known. We dissected Mozart's music into its compositional elements and studied their effects on metabolism of experimental animals. Mozart music significantly reduced cortisol level induced by stress. NMR metabolomic study revealed different urine metabolic profile according to the listening to Mozart's music. In addition, each element of music exhibited different metabolic profile. Functional MRI study also showed enhanced brain activity upon listening to Mozart's music. Taken together, Mozart's music seems to be related with brain activity, stress hormone and whole body metabolism.