• Title/Summary/Keyword: Body Pressure Sensor

Search Result 119, Processing Time 0.025 seconds

Sitting Posture-Based Lighting System to Enhance the Desired Mood

  • Bae, Hyunjoo;Kim, Haechan;Suk, Hyeon-Jeong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.191-198
    • /
    • 2015
  • Objective: As a cue for desired mood, we attempted to identify types of sitting postures when people are involved in various tasks during their working hours. Background: Physical behaviors in reaction to user contexts were studied, such as automated posture analysis for detecting a subject's emotion. Sitting postures have high feasibility and can be detected robustly with a sensing chair, especially when it comes to an office. Method: First, we attached seven sensors, including six pressure sensors and one distance sensor, to an office chair. In Part 1, we recorded participants' postures while they took part in four different tasks. From the seven sensors, we gathered five sets of data related to the head, the lumbar, the hip, thigh pressure and the distance between the backrest and the body. We classified them into four postures: leaning forward, upright, upright with the lumbar supporting, and leaning backward. In part 2, we requested the subjects to take suitable poses for the each of the four task types. In this way, we compared the matches between postures and tasks in a natural setting to those in a controlled situation. Results: We derived four types of sitting postures that were mapped onto the different tasks. The comparison yielded no statistical significance between Parts 1 and 2. In addition, there was a significant association between the task types and the posture types. Conclusion: The users' sitting postures were related to different types of tasks. This study demonstrates how human emotion can interact with lighting, as mediated through physical behavior. Application: We developed a posture-based lighting system that manipulates the quality of office lighting and is operated by changes in one's posture. Facilitated by this system, color temperatures ranging between 3,000K and 7,000K and illuminations ranging between 300lx and 700lx were modulated.

Implementation of Attitude measurement monitoring system and application according to pressure distribution (압력 분포에 따른 자세 측정 모니터링 시스템 및 어플리케이션 구현)

  • Jo, Yong-Woon;Ha, Eun-Gyo;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.629-630
    • /
    • 2017
  • Recently, the number of patients with habitual vertebrae is increasing due to inappropriate postures and habits while sitting on a chair for a long time, because modern people have a great deal of work and studying due to a lot of work and study. Therefore, it is necessary to prevent such a disease through real-time monitoring and to present a guide for the user to recognize the importance of correct posture. In this study, we implemented a posture discrimination system which can help users to calibrate posture by judging the user's sitting position and feedback by using a pressure sensor based weight distribution system. We analyzed the distribution pattern of body weight to determine one normal posture and six abnormal postures. If the abnormal posture is maintained constantly, the implementation of the application that induces the right posture by ringing the notification is described.

  • PDF

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.

The Scientific Analysis of Aged' Shoe for Health Promotion (노인 건강증진용 신발의 운동과학적 효과분석)

  • Jin, Young-Wan;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.9
    • /
    • pp.1336-1345
    • /
    • 2011
  • The purpose of this study was to analyze and compare the effects of exercise science of shoes for Aged' health promotion. Kinematic and kinetic data were collected using cinematography and the Zebris system (Zebris Emed Sensor Platform, GR-DVL9800) to analyze pressure of foot and ground reaction force. Subjects recruited were 20 healthy elderly men. They walked at 1.36m/sec velocity wearing type A (domestic), type B (foreign) and walking shoes (A company). One-way ANOVA was used to analyze statistics. The results were as following: no significant differences were observed in gait variables among the three groups (p<0.05). There was a significant difference in max pronation angle of heels examined among the three groups (p<0.05). There were no significant differences in kinetic variables (ground reaction force and max pressure) among the three groups (p<0.05). A physiology study was performed to analyze the effects of walking with shoes with silver added to them on percent body fat, resting metabolic rate and energy expenditure. Sixty adults males were recruited from the public health center. They were divided into four groups. C: control group (n=20), EY: elderly Y group (n=20), and EO: elderly O group (n=20). The results of this study were as follows: percent body fat was decreased following each exercise period, however, not all the groups showed a significant difference. The change of resting metabolic rate was significantly increased in HI (high intensity) and LI (low intensity) periods in the C and EY groups. However, there was no significant difference in the EO group. The mean energy expenditure during and after exercise were significantly lowered in all periods compared to the control group.

Active control of pump noise of dishwashers using FxLMS algorithm (FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어)

  • Tark, Un-su;Oh, Han-Eum;Hong, Chinsuk;Jeong, Weui-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • In this paper, active noise control was performed to reduce radiated noise in the low frequency band of dishwashers. First, through an analysis of the noise environment of the dishwasher, it was confirmed that the pump noise contributed the most to the radiated noise in the low frequency band, From the result of the noise environment analysis, the reference signal was selected to be the vibration signal of the pump body. The reference signal was obtained by using the accelerometer on the pump body, which can prevent acoustic feedback. The error signal sensor was selected as a microphone located at 1 m in front of the dishwasher and 0.5 m in height. And to design the controller, the error signal and the reference signal were measured at the operational rpms of the dishwasher at 2,500 rpm, 2,600 rpm and 2,800 rpm, and the secondary path transfer function was measured. The designed controller was mounted on Digital Signal Processor (DSP) equipment, and the control performance was verified experimentally. As a result of the measurement at the 3 operational rpms, the 7th multiple component of pump operating frequency decreased by 1.93 dB, 4.43 dB, 5.15 dB per rpm, and the 12th multiple component decreased by 6.67 dB, 2.34 dB, 4.28 dB per rpm. And overall Sound Pressure Level (SPL) decreased by 0.84 dB, 2.58 dB, 1.48 dB by rpm.

A Design of Passenger Detection and Sharing System(PDSS) to support the Driving ( Decision ) of an Autonomous Vehicles (자율차량의 주행을 보조하기 위한 탑승객 탐지 및 공유 시스템 개발)

  • Son, Su-Rak;Lee, Byung-Kwan;Sim, Son-Kweon;Jeong, Yi-Na
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.2
    • /
    • pp.138-144
    • /
    • 2020
  • Currently, an autonomous vehicle studies are working to develop a four-level autonomous vehicle that can cope with emergencies. In order to flexibly respond to an emergency, the autonomous vehicle must move in a direction to minimize the damage, which must be conducted by judging all the states of the road, such as the surrounding pedestrians, road conditions, and surrounding vehicle conditions. Therefore, in this paper, we suggest a passenger detection and sharing system to detect the passenger situation inside the autonomous vehicle and share it with V2V to the surrounding vehicles to assist in the operation of the autonomous vehicle. Passenger detection and sharing system improve the weighting method that recognizes passengers in the current vehicle to identify the passenger's position accurately inside the vehicle, and shares the passenger's position of each vehicle with other vehicles around it in case of emergency. So, it can help determine the driving of a vehicle. As a result of the experiment, the body pressure sensor applied to the passenger recognition sub-module showed about 8% higher accuracy than the conventional resonant sensor and about 17% higher than the piezoelectric sensor.

Design of Implantable Middle Ear Hearing Aids Using an Electromagnetic Transducer (전자 트랜스듀서 방식에 의한 청각보조용 이식형 인공중이 시스템 설계)

  • Cho, Jin-Ho;Song, Byung-Seop;Kim, Myoung-Nam;Won, Chul-Ho;Park, Se-Kwang;Lee, Sang-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.466-475
    • /
    • 1997
  • In this paper, an implantable middle ear hearing aids using an electromagnetic transducer which consists of a tiny coil and a magnet is designed, and objective design method to implement a vibrator of the electromagnetic type transducer is proposed. Sound characteristic of the electromagnetic type vibrator is excellent but power transfer rate is lower than that of a ceramic type. To improve power transfer efficiency of system, external and inner part of a middle ear system is designed using FM transmission method. We implemented an experimental set of the designed transducer, inner part, and outer part. Then, we measured vibration characteristics of a metal strip and a temporal bone of a dead body. As the results, we confirmed the advantage of FM method and showed that designed transducer could effectively transmit vibration of amplified input sound pressure to ossicle.

  • PDF

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.